BFCM- 10
Edwards Oil Mist Exhaust Filter
Edwards EMF20 Oil Mist Exhaust Filter The Edwards EMF20 Oil Mist Filter is designed for use with the Edwards RV12 and E2M18 vacuum pumps, efficient at 99.999% DOP test and azide proof. The bottom white half of the body is semi-transparent allowing easy monitoring of oil levels. This oil mist filter is new in the box and ready for shipping and includes: NW25 Clamp Centering Ring O-Ring NW25 to 3/4 inch BSP Adaptor 1 year warranty
$430.00
6" ASME VIII Sanitary 316SS Clamp for High Pressure Connections
6" ASME VIII Sanitary 316SS Clamp for High Pressure Connections These heavy duty hygienic ASME VIII clamps are designed for pressure vessels, filter housings and other demanding/pressure intensive applications while operating under sterile conditiions. These clampos meet the requirements of ASME SEction VII Appendinx 24 of the pressure vessel code . All of these sanitary clamps are made from fully traceable 316 stainless steel. The ASME Code Sanitary Clamp is made specifically for the Pharmaceutical and Biotech Industries where joint cleanliness and efficiency are of paramount importance. These stainless steel sanitary fittings and clamps are made from investment castings to produce a high quality, precision fit assembly. The clamps are designed to provide quick access to the joint for cleaning and inspection without sacrificing safety. All sanitary clamps are CE compliant per the Pressure Equipment Directive 97/23/EC and the Machinery Directive 98/37/EC. DATASHEET - ASME Sanitary Clamp Fittings ASME Clamp Instructions
$795.00
50L Neocision ETL Lab Certified Rotary Evaporator Turnkey System
50L Neocision ETL Lab Certified Rotary Evaporator Turnkey System 50L NEO Rotary Evaporator Turnkey System setup includes all the necessary components to successfully perform solvent recovery via rotary evaporation. A cold trap should always be used inline between your vacuum system and application to protect the pump from volatile vapors. 10-50L NEO and ECO Rotary Evaporator Diagram 50L NEO Rotary Evaporator Turnkey System setup includes: 50L Neocision ETL Lab Certified Rotary Evaporator Polyscience DuraChill 1.5HP Chiller w/ Turbine Pump 3/8" Gum Rubber - 100ft 3/8" Silicone Tubing - 25ft Welch BTpro100 Diaphragm Pump Adjustable Stainless Steel Hose Clamps This guide gives basic quick start instructions for rotovaps. It is intended to provide a starting point for learning the process. Parameters should be adjusted to suit specific needs. Clean and assemble unit. Make sure all pieces are cleaned and sterilized using an alcohol solution. Connect chiller to condenser and set to 0C (32F). Always fill a rotovap condenser from the top down (chiller output to top of condenser, chiller input to bottom of condenser). Connect vacuum pump to cold trap and connect cold trap to vacuum port on rotovap. Turn on heat bath and set to 40C (113F). Once heat bath, chiller and cold trap have reached desired temperatures, turn on rotovap motor and set speed to approximately 100 RPM (does not have to be precise). Keep in mind, higher RPM’s will increase evaporation power but also increase heat load. Start vacuum pump and allow vacuum to pull down for a few minutes before injection. Once vacuum has been pulled to a sufficient level (does not have to be precise but should be below 100 Torr), using the injection valve, very slowly inject approximately 500 mL of solution into evaporating flask and then close the valve. Allow this small amount to begin evaporating. You may see the chiller begin to rise in temperature, this is called “priming” the rotovap. Once the temperature stops rising or all liquid is almost completely evaporated, open the injection valve again very slowly so that a small amount of liquid begins to enter the evaporating flask. Do not close injection valve this time but continue to allow solution to enter the evaporating flask. At this point you must try to match the input speed to the output speed. What this means is that you should be injecting the same amount of liquid into the rotovap that is equal to the amount of liquid dripping from the condenser into the receiving flask. You will know that the input speed and output speed are matched because the chiller will remain at a stable temperature. If the chiller begins to rise, then you are injecting too much liquid. Dial back the valve until the chiller stabilizes. Once everything is stabilized, you may walk away from the rotovap if necessary. Check every so often to make sure temperatures remain stable and evaporation continues efficiently.
$19,750.00 - $22,500.00
5LB EVO Certified Closed Loop Extractor *49 State Certified
5LB Evo Certified Closed Loop Extractor Equipped with the latest in modern extraction technology the 5lb EVO produces extracts of the highest purity in the shortest time possible through its inline solvent chilling and adsorbent filtration capabilities using its unrestricted passive recovery speeds when paired with our 11KW Express Extraction Heater. Peer reviewed and 3P certified the 5lb EVO meets or exceeds Class 1 Division 1, NFPA 58, and ASME standards. With the ability to process 40+ pounds of biomass material every 8 hours the 5lb Evo provides precision performance without the price. Processing Power Capacity Per Batch: 5LB Cycle Time: 30-45 Minutes Capacity: Up to 40 lb, per 8-hour shift Extracts: isolate/sauce, distillate, vape pens, shatter, and wax/sugar 5LB EVO Certified Closed Loop Technical Data Sheet Specifications 6"x36" 5lb Material Column 6"x6" Adsorbent Filtration Column 1-5um Sintered disk filtration 1.5"x24" Inline molecular sieve column 7X 1.5" Certified Borosilicate Sight Glasses 3X 250 PSI ASME Safety Valves 3X -30hg-250PSI Compound Pressure Gauges 1.5" Full Bore Recovery Lines 1/2" JIC process Flow lines Footprint (DxWxH) 30"x40"x79" Weight: 400 lb Maximum Pressure Rating: 250PSI Compliance Class 1, Division 1 Compliant Designed to ASME standrds NFPA 58 LPG compliant 3P Certifed 49 State compliant: AL, AR, AZ, CA, CO, CT, DE, DC, FL, GA, HI, IA, ID, IL, IN, KS, KY, LA, ME, MD, MA, MI, MN, MS, MO, MT, NE, NV, NH,NM, NY, NC, ND, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WV, WY, WI Performance Jacketed or sleeved solvent column for prechilling of solvent & unbridled passive recovery Material Column solvent dispersal plate for complete biomass saturation 1500g Adsorbent filtration column complete with a 1-5um Sintered disk filter stack Independently Jacketed Material column, adsorbent filtration column, & collection column for complete process temperature control 1.5" full bore recovery lines for unrestricted solvent recovery Integrated -1.5"x24" Inline molecular sieve column for preserving solvent's effectiveness Easy to use extract pour spout for streamlined extract harvesting
$10,250.00 - $10,650.00
CHEMTEK W5 Neutral Bleaching Clay
CHEMTEK W5 Neutral Bleaching Clay W5 is a neutral bleaching clay specialized for the removal of heavy metals. While most sorbents will remove heavy metals, the acids involved in the activation process could cause desorption. By neutralizing the clay processors can take advantage of the increased surface area without any risk of desorption. W5 SDS W5 Technical Data Sheet
$40.00 - $200.00
5L Neocision ETL Lab Certified Rotary Evaporator Turnkey System
5L Neocision ETL Lab Certified Rotary Evaporator Turnkey System The 5L Neocision ETL Lab Certified Rotary Evaporator is a full-scale system meant to fulfill the needs of large volume production and meet the requirements of a certified laboratory with its ETL certification standards. Featuring an electric lift bath and all PTFE valves for extreme chemical resistance, the 5L Neocision gives users the ability to recover large amounts of solvent in a smaller footprint with highly improved functionality. All Neocision rotovaps feature high-efficiency valves and drain ports making it easy to directly inject solution continuously without the need to stop the system or release vacuum to drain. The temperature and rotation speed are easily controlled from a single digital interface. Our rotovaps are a fraction of the price of more costly systems with the same functionality and evaporation efficiency. 5L NEO Rotary Evaporator Turnkey System setup includes: 5L Neocision ETL Lab Certified Rotary Evaporator Polyscience LS -20C to 40C 1/2HP Chiller w/ Turbine Pump 1/4" Gum Rubber - 100ft 1/4" Silicone Tubing - 25ft Welch BTpro70 Adjustable Stainless Steel Hose Clamps Features: ETL Certified for Lab use. Digital temperature and speed control with simple user interface Electric Bath Lift Teflon Coated Bath for corrosion resistance High-efficiency drain port and injection valves Smaller footprint for improved workspace allocation Mobility with locking casters Shorter vapor path for faster evaporation and condensation Direct injection capability for continuous feeding of solution Continuous draining capability without the need to release vacuum or stop the system 1-year warranty on all mechanical parts. Does not include glassware. Specifications: Model 5L Solvent Pro Series Rotary Evaporator Optimum Ambient Temperature 5~25C / 41~105.8F Glass Material GG-17 High Borosilicate Power (V/Hz) 110V 50/60Hz Single Phase Speed Regulation Digital Step-less Regulation Rotation Speed 20-130 RPM Set Temperature RT+5 - 99C Temperature Control Digital Temperature Control Maximum Vacuum Pressure -29.8 inHg Evaporating Flask Capacity 5L (5000ml) Receiving Flask Capacity 5L (5000ml) Condenser Style Main + Auxiliary Vertical Double Helix Heater Max Current Draw (Amps) 25 Water Bath Material 304 Stainless Steel Water Bath Size 17.7 x 9.8 in. Lifting Function Electric Lifting Stroke 190mm / 7.5 in. Total Power Consumption (kW) 1800w Dimensions 45 x 32 x 15in Weight 155 lbs Vacuum Connection 14mm / .55 in. Barb Condenser Connection 18mm / .70 in. Barb Warranty 1 Year excluding glass parts Certifications ETL Rotovap Quick Start Guide This guide gives basic quick start instructions for rotovaps. It is intended to provide a starting point for learning the process. Parameters should be adjusted to suit specific needs. Clean and assemble unit. Make sure all pieces are cleaned and sterilized using an alcohol solution. Connect chiller to condenser and set to 0C (32F). Always fill a rotovap condenser from the top down (chiller output to top of condenser, chiller input to bottom of condenser). Connect vacuum pump to cold trap and connect cold trap to vacuum port on rotovap. Turn on heat bath and set to 40C (113F). Once heat bath, chiller and cold trap have reached desired temperatures, turn on rotovap motor and set speed to approximately 100 RPM (does not have to be precise). Keep in mind, higher RPM’s will increase evaporation power but also increase heat load. Start vacuum pump and allow vacuum to pull down for a few minutes before injection. Once vacuum has been pulled to a sufficient level (does not have to be precise but should be below 100 Torr), using the injection valve, very slowly inject approximately 500 mL of solution into evaporating flask and then close the valve. Allow this small amount to begin evaporating. You may see the chiller begin to rise in temperature, this is called “priming” the rotovap. Once the temperature stops rising or all liquid is almost completely evaporated, open the injection valve again very slowly so that a small amount of liquid begins to enter the evaporating flask. Do not close injection valve this time but continue to allow solution to enter the evaporating flask. At this point you must try to match the input speed to the output speed. What this means is that you should be injecting the same amount of liquid into the rotovap that is equal to the amount of liquid dripping from the condenser into the receiving flask. You will know that the input speed and output speed are matched because the chiller will remain at a stable temperature. If the chiller begins to rise, then you are injecting too much liquid. Dial back the valve until the chiller stabilizes. Once everything is stabilized, you may walk away from the rotovap if necessary. Check every so often to make sure temperatures remain stable and evaporation continues efficiently. ***Note: All units are inspected for broken glass or parts before unit is shipped. If unit arrives damaged or glass is broken (this does not include minor imperfections or scuffs in glassware), Customer MUST contact BVV™ within 3 days of delivery to file a claim and receive a replacement part. If customer DOES NOT contact BVV™ within 3 days of delivery responsibility for replacement parts falls on the customer and they must pay for replacement pieces.*** ***Note: This item will ship by freight only.*** ***Glassware Safety Disclaimer: BVV™ is not responsible for failure of glassware which must be inspected before and after every use because it may eventually develop imperfections or damage through normal usage, mishandling, and stress caused by temperature variations. If an imperfection or damage is noted while inspecting the glassware DO NOT use the glassware because it can fail causing bodily harm or damage to the surrounding area.***
$10,250.00 - $12,250.00
Half Ton - High Purity USA 50/25/25% N-Butane/Iso-Butane/Propane TRI-Blend - 99.5% Guaranteed
Half Ton - High Purity USA 50/25/25% N-Butane/Iso-Butane/Propane TRI-Blend - 99.5% Guaranteed DISCLAIMER(S): This unit is intended for LEGAL purposes only, to be used in accordance with local laws and ordinances. Use only in WELL VENTILATED AREAS! Notice: This item will ship via Freight ONLY. This tank requires a CGA 510 fitting - Sold Separately BVV™ always recommends distillation of every solvent before use. *Actual liquid weight is 482LB California now prohibits the retail sale of any Non-Odorized butane in quantities larger than 150ml. If you are not a retail purchaser you can call in to place an order. Permitted Sales Include the Following: Medical Collectives or Cooperatives operating under CA Health & Safety Code Section 11362.775 Persons licensed to perform volatile solvent extraction activity under CA Bus & Prof Code Division 10 Manufacturers, wholesalers, resellers, or retailers solely for the purpose of resale High purity 50/25/25% N-Butane/Iso-Butane/Propane TRI-Blend is USA sourced, and guaranteed to be 99.5% pure. This instrument grade solvent helps to produce a higher quality extract by reducing mystery oils and contaminants. Solvent comes in a DOT refillable LP tank with liquid withdrawal valve (Diptube). This product is clean, colorless and odorless. *Actual liquid weight is 482LB BVV™ Tri-Blend SDS Due to FAA regulations, solvent tanks cannot be safely transported via means other than ground. Any order that has solvent will not be shipped in an expedited fashion. If an order with solvent is combined with any other items and chosen to be expedited, that entire order will ship via UPS Ground/Freight. We will not split up any orders and ship them separately. If a customer is wanting to expedite specific items and order solvent, 2 separate orders (1 for the solvent and 1 for the expedited items) will need to be placed in order to do so. Solvents do not ship to Hawaii, Puerto Rico, or any other US Territory outside of the contiguous 48 States. Shipping Solvent to Alaska may ONLY ship via freight and will be required to travel through Canada. We have this policy in place to ensure safety when transporting solvents, and to prevent any issue with shipping times for our customers.
$2,940.00
CHEMTEK D-Wax
D-Wax is a silica with high adsorption capacity and strong affinity for phospholipids, trace metals, and soaps. It contains 50% water and citric acid to remove both hydratable and non hydratable phosphatides. D-Wax SDS
$80.00 - $460.00
10L Premium Short Path Distillation Turnkey System
10L Premium Short Path Distillation Turnkey System This unit carries a 2 day lead time. (Note: Stainless Steel Table NOT Included.) The 10L Premium Short Path Distillation Turnkey System features our USA made P10 Distillation Head. Every component in this turnkey is made for precision, throughput, and repeatable results. Also included the Kangaroo digital thermometer which is very rugged and reliable. You will also receive a Ribbed Dewar Style Glass Cold Trap to keep all volatiles and solvents out of your vacuum system. This Turnkey Setup gives you everything needed to perform distillation at the highest level. The 10L Neo Kit Includes: 10L Short Path Distillation Kit including glassware, labware, and P10 Distillation Head. 10L Digital Heating and Stirring Mantle. Polyscience 15 Liter Advanced Digital Heated Circulator BVV™ 21.2CFM Pro Series Corrosion Resistant Vacuum Pump Valved Vacuum Adapter. Ribbed Dewar Style Glass Cold Trap. Kangaroo Digital Thermometer. Distillation Quick Start Guide This guide gives basic quick start instructions for distillation systems. It is intended to provide a starting point for learning the process. Parameters should be adjusted to suit specific needs, Before beginning distillation, ensure the following steps have been taken: Vacuum Pump is in good working order. Pump should be run against dry load to allow internals to warm up. Oil should be clear. Cloudy or dark oil should be changed. All glass components are in good working order and ready to be assembled A winterization and degassing procedure has been done to prepare oil for distillation The unit's max internal temperature cannot exceed 380C. The recommended max set temperature should not exceed 250C Once all three of these steps have been completed, you are ready to begin distilling. Begin by placing stir bar in boiling flask and then load your material. This should be done using a funnel. A small amount of alcohol in the oil will give it a thinner consistency making it easier to transfer. Assemble all glassware and ensure each joint is properly greased. Do not use too much, as the vacuum pressure might pull some grease into the system. To ensure a full seal, spread grease in a circular motion by rotating glassware Attach circulator to condenser and set temperature to 50C. Allow circulator to reach temperature before beginning distillation. Connect vacuum pump to manifold. The manifold will allow you to isolate each individual component as well as let atmosphere into and out of the system. Connect receiving cow to cold trap. Connect cold trap to manifold. Connect vacuum gauge to manifold. At this point, ensure all connections are correct. Also ensure receiving cow is positioned to collect the first fraction in the far-left receiving flask. Circulator should be at its set temperature. Turn on vacuum pump to begin process. Turn on heat and set to 60C. Vacuum pump will begin to pull down and temperature will begin to rise. Watch the gauge to monitor vacuum pressure and stability. Start stir slower and increase speed with temperature. Once you are close to 60C, increase the temperature 20 degrees. Continue to raise the heat incrementally in 20-degree steps, increasing the set temperature as you near your set point. Increase temperatures incrementally until you reach 220C. You will see your first fraction somewhere between 180C and 190C or slightly before. This is the “heads” fraction. You will move to your second fraction when you see an increased reaction in the head, a slight color change toward golden, as well as a thickening of distillate. When this fraction hits, allow the distillate to “self-clean” the head for a minute or two then, rotate the cow to the middle receiving flask. Collect your “main body” fraction. You will see temps between 190-220C during this fraction. Continue to increase stirring speed as necessary. Reaction in the head may vary but it should never stop. As fluid level in the boiling flask decreases, increase stir speed. The final “tails” fraction is a mixture of the first and second fractions and should be saved for re-distillation later. Ideally, you want to turn the cow to the final flask before the tails fraction hits. The “tails” fraction has an obvious color change and will be darker than the “main body” fraction. You will see temps between 200-250C during this fraction. As fluid level in the boiling flask decreases even more, set stirring RPM higher (1000+ RPM). You may need to compensate with a bit more heat to finish of the final fraction as well. Once process is complete, stop heat, stop stir, and stop vacuum. Let atmosphere into the system. Be sure to properly store your distillate as exposure to air and light can cause oxidation. ***Note: This entire setup will ship via motor freight.*** ***Note: All units are inspected for broken glass or parts before unit is shipped. If unit arrives damaged or glass is broken (this does not include minor imperfections or scuffs in glassware), Customer MUST contact BVV™ within 3 days of delivery to file a claim and receive a replacement part. If customer DOES NOT contact BVV™ within 3 days of delivery responsibility for replacement parts falls on the customer and they must pay for replacement pieces.*** ***Glassware Safety Disclaimer: BVV™ is not responsible for failure of glassware which must be inspected before and after every use because it may eventually develop imperfections or damage through normal usage, mishandling, and stress caused by temperature variations. If an imperfection or damage is noted while inspecting the glassware DO NOT use the glassware because it can fail causing bodily harm or damage to the surrounding area.***
$11,500.00
ASME-Code Fast-Acting Pressure-Relief Valve for Air, Test Ring, Brass Seal, 1/4 NPT, 3-1/8" High
ASME-Code Fast-Acting Pressure-Relief Valve for Air, Test Ring, Brass Seal, 1/4 NPT, 3-1/8" High Valve Function Pressure Relief For Use With Air, Inert Gas Activation Pressure Driven Inlet Pipe Size 1/4 Connection Type Pipe Pipe Connection Type Threaded Connection NPT Male Location Bottom Maximum Pressure 300 psi Relief Port Connection Type Vent Relief Port Location Side Set Pressure Configuration Nonadjustable Temperature Range -40° to 400° F Valve Shape 90° Elbow Valve Body Shape Straight Overall Height 3 1/8" Material Body Brass Seal Brass Test Mechanism Ring Valve Type Pop Safety Specifications Met ASME BPVC.VIII RoHS RoHS 3 (2015/863/EU) compliant with exemption 6(c) - Lead in copper alloy REACH REACH (EC 1907/2006) (07/08/2021, 219 SVHC) Compliant DFARS Specialty Metals COTS-Exempt Country of Origin United States USMCA Qualifying No Schedule B 848140.0000 ECCN EAR99 To protect against damage in air lines, air receivers, compressor tanks, and other air-powered equipment, these valves spring fully open at the set pressure and remain open until the system pressure is restored below the set pressure. All meet ASME Code Section VIII for use with air and inert gas pressure vessels. They have a vented relief port to exhaust discharge directly.
$50.00
Pump Rebuild Kits for 14.1 - 21.2 - 35.3 Pro Series Pumps
Pro Series Vacuum Pump Complete Service Kit This is a complete vacuum pump service kit for the BVV™ Pro Series 14.1, 21.2, 35.3CFM line of vacuum pumps and allows the user to completely rebuild their pump and keep it running like new.
$425.00 - $550.00
1/2" x 0.035 wall 316SS Hard Line Tubing 5FT
1/2" 316SS Hard Line Tubing 5FT Stainless Steel 316 Hard line tubing for compression fitting connections and systems. Specifications Length 5' Material 316 Stainless Steel ASTM A-269 Max Allowed Working Pressure (PSIG) 1/2" x .035 2339
$60.00
3.5CFM Dry Floating Scroll Vacuum Pump #1 Candy Drying Vacuum Pump
3.5CFM Dry Floating Scroll Vacuum Pump 1 Candy Drying Vacuum Pump Oil and Maintenance Free! Introducing the BSVF6 Vacuum Pump, equipped with cutting-edge patented floating scroll technology for unparalleled performance. This pump boasts a 3.5CFM (100 L/min) pump speed and an ultimate pressure of 25 Microns (≤ 0.03 mbar), making it a powerhouse in creating and maintaining vacuums. The 100% oil-free design ensures clean and efficient operation, while the brushless DC motor, with 350W motor power and 200W installed power, provides reliability and longevity. With a compact size ideal for portable equipment, this vacuum pump offers unlimited vapor tolerance and a noise level as low as 55 dB(A) with its case. The SVF-E2-100 is maintenance-free, featuring a robust build with inlet/outlet connections in KF-25, air-cooled cooling system, and a wide ambient temperature range from -40ºC to 50ºC. Elevate your vacuum processes with this advanced, compact, and powerful solution. Specifications Model BSVF6 Pump Speed 100 L/min Ultimate Pressure ≤ 0.03 mbar (25 Micron) Motor Power 350 W Installed Power 200 W Motor Type Brushless DC Motor DC Voltage 48 VDC AC Voltage (with adapter) 100 – 240 VAC Maximum Speed 4000 RPM Vapor Tolerance Unlimited Maximum Inlet Speed Unlimited Maximum Outlet Speed 1 barg Noise Level (With Frame) 60 dB(A) Noise Level(With Case) 55 dB(A) Weight (With Frame) 7.5 kg Weight (With Case) 8.5 kg Dimensions (With Frame) 324×225×175mm Dimensions (With Case) 394×236×189mm Inlet/Outlet Connection KF-25 or G 3/8″ Cooling System Air – Cooled Ambient Temperature -40ºC to 50ºC
$1,550.00
Welch CRVpro Direct Drive Rotary Vane Vacuum Pump CRVpro8
Welch CRVpro Direct Drive Rotary Vane Vacuum Pump CRVpro8 ***Note: This item has a possible 1-2 week lead time depending on stock availability*** Product Details The new CRVpro family of direct drive vacuum pumps offers increased reliability and longer service interval vs. other direct drive rotary vane vacuum pumps. The CRVpro family consumes up to 36% less oil than comparable pumps. Three features drive these benefits: Runs 10°C cooler than comparable pumps. Slows corrosion. Has a 40% larger oil capacity than comparable pumps. Dilutes aggressive chemicals. Has a chemical resistant coating in the oil case and pump module. Protects non-moving parts. The CRVpro family includes all the features you'd expect in a direct drive rotary vane pump: gas ballast, forced oil lubrication, anti-suckback mechanism and thermal overload protection. Suitable applications include freeze drying, degassing, vacuum ovens and concentrators. 3081-01 is wired for North American 115V, 60Hz operation. Includes North American line cord, vacuum inlet hose barb suitable for gum rubber hose from 5/8" to 3/4" ID, and a charge of oil. 3082-01 is wired for North American 230V, 60Hz operation. Includes 230V North American line cord, UK cord, and skuko cord, and a charge of oil. Direct drive pumps are not recommended for filtration, aspiration, drying electrophoresis gels, or other applications requiring sustained operation above 30 torr Specifications Application CRVpro8 Free Air Displacement @ 60 Hz, cfm (L/min) 5.6 (158) Free Air Displacement @ 50 Hz, m³/hr (L/min) 8 (133) Ultimate Pressure, torr (mbar) 5x10⁻⁴ (4x10⁻⁴) Noise Level, dBA 50 Motor Speed, RPM, @60Hz, @50Hz 1740 (1450) Motor Power, HP (kW) 0.4 (0.5) Oil Capacity, mL 1000 Connection Flanges NW 16 Inlet Hose Connection* 5/8" to 3/4" Weight, lbs (kg) 49.6 (22.5) Dimensions, LxWxH, in (mm) 18.2x6.1x9.1 (463x157x230)
$3,345.00
10L Neocision ETL Lab Certified Rotary Evaporator Turnkey System
10L NEO Rotary Evaporator Turnkey System 10L NEO Rotary Evaporator Turnkey System setup includes all the necessary components to successfully perform solvent recovery via rotary evaporation. A cold trap should always be used inline between your vacuum system and application to protect the pump from volatile vapors. 10-50L NEO and ECO Rotary Evaporator Diagram 10L NEO Rotary Evaporator Turnkey System setup includes: 10L Neocision ETL Lab Certified Rotary Evaporator Polyscience 6160T 1HP Chiller 3/8" Gum Rubber - 100ft 3/8" Silicone Tubing - 25ft Welch BTpro100 Diaphragm Pump Adjustable Stainless Steel Hose Clamps This guide gives basic quick start instructions for rotovaps. It is intended to provide a starting point for learning the process. Parameters should be adjusted to suit specific needs. Clean and assemble unit. Make sure all pieces are cleaned and sterilized using an alcohol solution. Connect chiller to condenser and set to 0C (32F). Always fill a rotovap condenser from the top down (chiller output to top of condenser, chiller input to bottom of condenser). Connect vacuum pump to cold trap and connect cold trap to vacuum port on rotovap. Turn on heat bath and set to 40C (113F). Once heat bath, chiller and cold trap have reached desired temperatures, turn on rotovap motor and set speed to approximately 100 RPM (does not have to be precise). Keep in mind, higher RPM’s will increase evaporation power but also increase heat load. Start vacuum pump and allow vacuum to pull down for a few minutes before injection. Once vacuum has been pulled to a sufficient level (does not have to be precise but should be below 100 Torr), using the injection valve, very slowly inject approximately 500 mL of solution into evaporating flask and then close the valve. Allow this small amount to begin evaporating. You may see the chiller begin to rise in temperature, this is called “priming” the rotovap. Once the temperature stops rising or all liquid is almost completely evaporated, open the injection valve again very slowly so that a small amount of liquid begins to enter the evaporating flask. Do not close injection valve this time but continue to allow solution to enter the evaporating flask. At this point you must try to match the input speed to the output speed. What this means is that you should be injecting the same amount of liquid into the rotovap that is equal to the amount of liquid dripping from the condenser into the receiving flask. You will know that the input speed and output speed are matched because the chiller will remain at a stable temperature. If the chiller begins to rise, then you are injecting too much liquid. Dial back the valve until the chiller stabilizes. Once everything is stabilized, you may walk away from the rotovap if necessary. Check every so often to make sure temperatures remain stable and evaporation continues efficiently. **Note: All units are inspected for broken glass or parts before unit is shipped. If unit arrives damaged or glass is broken (this does not include minor imperfections or scuffs in glassware), Customer MUST contact BVV™ within 3 days of delivery to file a claim and receive a replacement part. If customer DOES NOT contact BVV™ within 3 days of delivery responsibility for replacement parts falls on the customer and they must pay for replacement pieces.*** ***Note: This item will ship by freight only.*** ***Glassware Safety Disclaimer: BVV™ is not responsible for failure of glassware which must be inspected before and after every use because it may eventually develop imperfections or damage through normal usage, mishandling, and stress caused by temperature variations. If an imperfection or damage is noted while inspecting the glassware DO NOT use the glassware because it can fail causing bodily harm or damage to the surrounding area.***
$12,450.00 - $15,005.00
BVV 2 Cylinder Active Closed Loop Recovery Kit ITS/ETL to ANSI/ISA Certified
BVV 2 Cylinder Active Closed Loop Recovery Kit ITS/ETL to ANSI/ISA Certified (Pump comes with 1 yr. limited warranty) This is an Upgrade Kit which can be added to any one of our passive systems making it into an "Active" Closed Loop System. The Active Recovery Upgrade Kit will increase recovery times by condensing the vapor a lot faster than just a hot/cold differential. This will increase efficiency and productivity, many professionals use this method, as this drives profits. This Kit Includes the Following: BVV 2 Cylinder Butane Recovery Pump ITS/ETL to ANSI/ISA Certified BVV Large Condensing Coil 1/2" x 24" SS JIC Braided Hose (2) 1/2" x 48" SS JIC Braided Hose (2) 1/2" x 60" SS JIC Braided Hose Molecular Sieve Filter Drier BVV 5' HVAC Hose BVV Vacuum Tee RECOVER MORE WITH LESS BVV is proud to introduce our new and powerful line-up of Butane & Propane Recovery Pumps. Blending compact design with improved Gen III Pistons from RKMAC, this collection of pumps can help you recover 1lb. of butane every 1:40 Seconds! This pump Assembled in the USA and all the critical parts are domestically made. Finding parts wont be an issue with this pump. The piston seals are rated to 450F and the average operating temperature of the pump is 175F leading to a long service life. Certified by ITS/ETL to ANSI/ISA 12.12.01 for Use in Hazardous locations Class I & II, Division 2 and Class III, Divisions 1 & 2 environments. The computer controlled brushless DC motor operates at 3000 RMP nearly twice as fast as any other pump in its class. BVV Butane/Propane Recovery Pumps are: Process up to 10,000 lbs. of vapor recovery before rebuild Equipped with oil-less reciprocating compressors for a clean product Designed and Assembled in the U.S.A. with domestic and global parts Affordable and highly cost efficient Available in 2-Cylinder, 4-Cylinder, CMEP Retrofit Comes with a 1-year Manufacturer’s Warranty covering Hemp usage Rated universal voltage 100-240V AC 50/60 Hz 1Ph Built with high efficiency Brushless DC Motor used for variable speed control Equipped with Viton O-Ring Seals for Butane/Propane gas and oil compatibility Certified by ITS/ETL to ANSI/ISA 12.12.01 Noise level: 90.3 dB at 1m *Butane recovery results were achieved on a collection base pressure greater than 30psi and using a recovery cylinder with a pressure <10psi. A dry ice coil was used in between the output port of the pump and the recovery cylinder to condense vapor.
$2,500.00 - $2,600.00
LOCTITE 24205 THREADLOCKER 242 MED STRENGTH
Prevents loosening and leakage of threaded fasteners. Particularly suitable for applications such as pump or motor mounting bolts, engine rocker nuts or equipment housing screws, where disassembly with hand tools is required for servicing. Anaerobic Acrylic Threadlock Sold as .5 ml pack
$7.00
Half Ton - High Purity USA Propane - 99.5% Guaranteed
Half Ton High Purity USA PROPANE - 99.5% Guaranteed DISCLAIMER(S): This unit is intended for LEGAL purposes only, to be used in accordance with local laws and ordinances. Use only in WELL VENTILATED AREAS! Notice: This item will ship via Freight ONLY. This tank requires a CGA 510 fitting - Sold Separately BVV™ always recommends distillation of every solvent before use. *Actual liquid weight is 420LB California now prohibits the retail sale of any Non-Odorized butane in quantities larger than 150ml. If you are not a retail purchaser you can call in to place an order. Permitted Sales Include the Following: Medical Collectives or Cooperatives operating under CA Health & Safety Code Section 11362.775 Persons licensed to perform volatile solvent extraction activity under CA Bus & Prof Code Division 10 Manufacturers, wholesalers, resellers, or retailers solely for the purpose of resale High purity Propane is USA sourced, and guaranteed to be 99.5% pure. This instrument grade solvent helps to produce a higher quality extract by reducing mystery oils and contaminants. Solvent comes in a DOT refillable LP tank with liquid withdrawal valve (Diptube). Lot Analysis: Propane: 99.5% + Methane: <1ppm Ethane: 3ppm Isobutane: 2380ppm n-Butane: 251ppm Propylene: <5ppm Isopentane: <1ppm Water: <3ppm Sulfer: <1ppm *Free of any hydrogen Sulphide based Ethyl Mercaptan Odorants. *This product is clean, colorless and odorless. *Actual Propane liquid weight is 420LB Due to FAA regulations, solvent tanks cannot be safely transported via means other than ground. Any order that has solvent will not be shipped in an expedited fashion. If an order with solvent is combined with any other items and chosen to be expedited, that entire order will ship via UPS Ground/Freight. We will not split up any orders and ship them separately. If a customer is wanting to expedite specific items and order solvent, 2 separate orders (1 for the solvent and 1 for the expedited items) will need to be placed in order to do so. Solvents do not ship to Hawaii, Puerto Rico, or any other US Territory outside of the contiguous 48 States. Shipping Solvent to Alaska may ONLY ship via freight and will be required to travel through Canada. We have this policy in place to ensure safety when transporting solvents, and to prevent any issue with shipping times for our customers.
$2,800.00
10L Neocision Dual Head Short Path Distillation Kit
10L Neocision Dual Head Short Path Distillation Kit This unit carries a 2 day lead time. The 10L Neocision Distillation Turnkey Setup features our Dual 10L P5 Distillation Heads and USA made glass. Every component in this turnkey is made for precision, throughput, and repeatable results. Also included the Bullseye Precision Vacuum Gauge from Digivac which is the most rugged and dependable vacuum gauge on the market. You will also receive a Dual Dewar Style Glass Cold Trap to keep all volatiles and solvents out of your vacuum system. This Turnkey Setup gives you everything needed to perform distillation at the highest level. The 10L Neo Kit Includes: 10L Neocision Kit with Dual P5 Distillation Heads KF-25 90 Degree Long Manifold and Metering Valve Dual Dewar Style Glass Cold Trap Bullseye Precision Vacuum Gauge Distillation Quick Start Guide This guide gives basic quick start instructions for distillation systems. It is intended to provide a starting point for learning the process. Parameters should be adjusted to suit specific needs, Before beginning distillation, ensure the following steps have been taken: Vacuum Pump is in good working order. Pump should be run against dry load to allow internals to warm up. Oil should be clear. Cloudy or dark oil should be changed. All glass components are in good working order and ready to be assembled A winterization and degassing procedure has been done to prepare oil for distillation Once all three of these steps have been completed, you are ready to begin distilling. Begin by placing stir bar in boiling flask and then load your material. This should be done using a funnel. A small amount of alcohol in the oil will give it a thinner consistency making it easier to transfer. Assemble all glassware and ensure each joint is properly greased. Do not use too much, as the vacuum pressure might pull some grease into the system. To ensure a full seal, spread grease in a circular motion by rotating glassware Attach circulator to condenser and set temperature to 50C. Allow circulator to reach temperature before beginning distillation. Connect vacuum pump to manifold. The manifold will allow you to isolate each individual component as well as let atmosphere into and out of the system. Connect receiving cow to cold trap. Connect cold trap to manifold. Connect vacuum gauge to manifold. At this point, ensure all connections are correct. Also ensure receiving cow is positioned to collect the first fraction in the far-left receiving flask. Circulator should be at its set temperature. Turn on vacuum pump to begin process. Turn on heat and set to 60C. Vacuum pump will begin to pull down and temperature will begin to rise. Watch the gauge to monitor vacuum pressure and stability. Start stir slower and increase speed with temperature. Once you are close to 60C, increase the temperature 20 degrees. Continue to raise the heat incrementally in 20-degree steps, increasing the set temperature as you near your set point. Increase temperatures incrementally until you reach 220C. You will see your first fraction somewhere between 180C and 190C or slightly before. This is the “heads” fraction. You will move to your second fraction when you see an increased reaction in the head, a slight color change toward golden, as well as a thickening of distillate. When this fraction hits, allow the distillate to “self-clean” the head for a minute or two then, rotate the cow to the middle receiving flask. Collect your “main body” fraction. You will see temps between 190-220C during this fraction. Continue to increase stirring speed as necessary. Reaction in the head may vary but it should never stop. As fluid level in the boiling flask decreases, increase stir speed. The final “tails” fraction is a mixture of the first and second fractions and should be saved for re-distillation later. Ideally, you want to turn the cow to the final flask before the tails fraction hits. The “tails” fraction has an obvious color change and will be darker than the “main body” fraction. You will see temps between 200-250C during this fraction. As fluid level in the boiling flask decreases even more, set stirring RPM higher (1000+ RPM). You may need to compensate with a bit more heat to finish of the final fraction as well. Once process is complete, stop heat, stop stir, and stop vacuum. Let atmosphere into the system. Be sure to properly store your distillate as exposure to air and light can cause oxidation. ***Note: This entire setup will ship via motor freight.*** *Notice to Customers: All units are inspected for broken glassware or parts before leaving BVV™. If the unit arrives damaged (this does not include minor imperfections or scuffs in glassware), the customer MUST contact BVV™ within 72 hours from carrier delivery to file a claim. If the customer DOES NOT contact BVV™ within 72 hours from carrier delivery, then BVV™ cannot issue any replacement(s) or compensation for the item; a new purchase will need to be made for a replacement. BVV™ is not responsible for the failure of glassware which must be inspected before and after every use because it may eventually develop imperfections or damage through normal usage, mishandling, and stress caused by temperature variations. If an imperfection or damage is noted while inspecting the glassware DO NOT use the glassware because it can fail, which can cause bodily harm or damage to the surrounding area.
$9,200.00
Polyscience 10 Liter General Purpose Water Bath
Polyscience 10 Liter General Purpose Water Bath Key Features: Displays actual and set point temperature simultaneously Three push-button pre-sets for frequently used temperatures Integrated timer Hinged gable cover Calibration capability Reservoir sizes from 2 to 28 liters Reservoir made of 304 Stainless Steel Reservoir drain (10 liter and larger baths) Primary and automatic safety thermostats Also compatible with waterless bath beads Specifications Working Temperature Range °F Ambient +10° to 212° Reservoir Capacity (liters) 10 Reservoir/Tank Material Stainless Steel Reservoir Cover Hinged Gable Working Access (L x W x D) (inches) 10.6 x 11.6 x 6 Temperature Stability °F ±0.2° Display 3.25" Flammability Class (DIN 12876-1) I (NFL) Over-Temperature Protection / Failsafe Heater Control Yes Maximum Ambient Temperature °F 104° Overall Dimensions (L x W x H) (inches) 17 x 15.5 x 15.5 Shipping Weight (pounds) 22.0 60Hz Only Part Number WBE10A11B Included Hardware Sample Tray Heater Wattage 1000 Electrical Requirements (VAC/Hz/Ph/A) 120/60/1/8.6 Regulatory Approvals ETL Certifications: Regulatory Approvals: ETL Regulatory Approvals: CE
$974.00
1.5" Tri-clamp Thermometer
1.5" Tri-clamp Thermometer High-quality adjustable stainless dial 1.5" Tri-clamp thermometer with back mount orientation. This thermometer is perfect for process temperature monitoring in sanitary applications allowing precise monitoring of temperature. The stainless Dial Thermometer face is 3-inch diameter and reads 0 to 220 degrees in Fahrenheit and 0 to 100 degrees in Celsius. This thermometer is 1.5″ Tri-clamp and the probe depth from the tri-clamp is 2″ long.
$50.00
CannaClean SC-1 Industrial Resin Cleaner Concentrate
CannaClean SC-1 Full Concentrate Undiluted The Preferred Cleaner @ BVV! Designed to clean all sticky resin messes. This industrial cleaner can be used to clean worksurfaces, ovens, handles, doors, intricate glassware, extractor parts, scissors, automated machines and any instruments or tools used that comes into contact with the sticky resins we all know. What sets this cleaner apart is the application. D'limonene has been the go to for labs, but it always leaves behind the oily residue since its a pure oil based terpene. CannaClean SC-1 leaves NO residue behind on any surface. Making this a one step cleanup product! Use as is or dilute with water (we recommend no more than 50% dilution) Apply with spray or cloth. *SC1-Wipes are fully concentrated wipes ready for use! 75 wipes per bottle. CannaClean SC-1 Safety Data Sheet (SDS) CannaClean SC-1 Material Compliance Statement
$15.00 - $300.00
280L Jacketed Stainless Steel Centrifuge with Explosion Proof Motor and Siemens Controller - 85LB Max Capacity
280L Ethanol Wash/Dry Centrifuge NOTE: This item currently has a 2 week lead time. Industrial Centrifuges are used to separating liquids from solids and this style of centrifuge excels at alcohol extraction by forcefully separating the alcohol from the biomass. Notice to Customer: This unit has 4 lift points (one in each corner) and requires a forklift to lift it and will also ship via freight only. Key Features: Siemens Touch Screen Controller Explosion Proof Controller Housing and Motor Agitation and Spin Dry Modes Max 1000 RPM with Gradual Speed Stepping 559 Separation Factor Multiple Connection Ports/Sizes High Polish Stainless Steel Components Shock absorbing legs Vacuum Jacket with Two 1" Tri-Clamp Fittings Pre-wired and Tested for Easy Installation Specifications Capacity 280L Drum Dimensions 39.4" (1000mm) Diameter x 14.17" (360mm) Speed 0-1000r/min Weight 4,188lbs (1900KG) Exterior Dimensions 59.06" x 82.68" x 45.28" (1500x2100x1150mm) Material 304 Stainless Steel Motor Power 11KW Explosions Proof - 220v 60Hz 3 Phase
$36,000.00
Neoprene Gasket for Cubes
NEOPRENE GASKET FOR CUBES Replacement Neoprene gasket for acrylic vacuum chambers. The existing gasket will have to be completely removed in order to get the new one to seal. It is recommended to use a cleaning solution such as CitraKlean.
$39.00
2" Plastic Drum Faucet
Recommended for dispensing light oils, acids and cleaning solutions. FDA approved high-density polyethylene (HDPE) plastic faucet. The faucet is designed to fit 2" NPT threads and can be used to dispense most non-flammable liquids. Use with plastic and steel drums. Tough polyethylene. FDA compliant. Material: High density polyethylene (HDPE ) is the most commonly used resin. This economical plastic has good impact resistant, is naturally translucent, flexible, and typically used for personal care products, such as shampoo bottles. Adding color will give HDPE an opaque look that will result in an increase in weight and rigidness. We have a variety of these rigid and tough high density polyethylene products in stock, from containers, pails, bottles, caps, tubs, and jugs. HDPE works well in below freezing temperatures. HDPE heat compatibility varies. Generally, it should not be used with products filled at over 145°F.
$25.00
Welch BTpro70
Welch BTpro70 ***Note: This item has a possible lead time of 2-3 weeks depending on stock availability.*** Welch’s BTpro vacuum pump series has a flow and vacuum level to provide fast performance for your size of rotary evaporator, glass reactor, purge oven, or winterization filtration apparatus. These chemical duty PTFE diaphragm pumps are oil-free. The pumping action and deep vacuum comes from the movement of PTFE diaphragms within PTFE heads. All wetted services in the flow path are made of fluoroplastic making the BTpro pump highly chemically resistant. As a result, the BTpro vacuum pump series is near-zero maintenance. A cold trap placed in-line with BTpro pump is needed if terpenes are part of the flow path. The BTpro40 and BTpro70 models employ patented valve and diaphragm technology that generates a deep 15 Torr vacuum pressure with each PTFE head. In addition, both pump models have built-in tuneable vacuum to control evaporation rate. The tunable vacuum adjustment can also be used to stop accidental bumping/foaming. Model BTpro70 Free Air Displacement@60Hz,lpm(CFM) 70(2.5) Ultimate Vacuum Pressure, Torr 15 Maximum Vacuum, in. Hg 29.3 Horsepower, HP (watts) 1/5(150) Built-in adjustable vacuum Yes Gas Ballast - Head Material PTFE Diaphragm PTFE Inlet/outlet Connection 3/8” barb Agency (National Recognized Lab) CSA Weight, lbs (kg) 21.3(9.6) Overall Dimensions LxWxH in.(cm) 13.8x6.8x8.8 35x17x22 Shipping Weight, lbs(kg) 25 (11.3) Shipping Carton Dimensions LxWxH in.(cm) 21x14x15 (52x35x37)
$2,781.00
NEO 1.4CFM Diaphragm Pump ETL RATED
The BVV V series pumps are Ani-corrosion PTFE diaphragm vacuum pumps. The two head design operates as a two-stage pump to achieve a lower degree of vacuum. They are ideal for pumping corrosive gases and organic solvents. These pumps do not need any pump oil or other lubricants, which means less maintenance and smaller chance for cross contamination. The BVV V-40 is ETL listed to be used in laboratories and comes with a 1 year manufacturer warranty on all non consumable pieces. Model V-40 Power 110V 60Hz, 240 W Ultimate Vacuum 6 torr (8mbar) Maximum Operating Pressure 1 bar Maximum Flow 40 L/min Ambient Temperature 5 - 40°C Pump Head Material PTFE Composite Valve Material FFPM Noise <70db Dimensions 315x165x210mm Weight 10.4 kg For replacement diaphragms, click HERE
$1,950.00
Welch BTpro40
Welch BTpro40 (CSA) Certified ***Note: This item has a possible lead time of 2-3 weeks depending on stock availability.*** Welch’s BTpro vacuum pump series has a flow and vacuum level to provide fast performance for your size of rotary evaporator, glass reactor, purge oven, or winterization filtration apparatus. These chemical duty PTFE diaphragm pumps are oil-free. The pumping action and deep vacuum comes from the movement of PTFE diaphragms within PTFE heads. All wetted services in the flow path are made of fluoroplastic making the BTpro pump highly chemically resistant. As a result, the BTpro vacuum pump series is near-zero maintenance. A cold trap placed in-line with BTpro pump is needed if terpenes are part of the flow path. The BTpro40 and BTpro70 models employ patented valve and diaphragm technology that generates a deep 15 Torr vacuum pressure with each PTFE head. In addition, both pump models have built-in tuneable vacuum to control evaporation rate. The tunable vacuum adjustment can also be used to stop accidental bumping/foaming. Model BTpro40 Free Air Displacement@60Hz,lpm(CFM) 40(1.4) Ultimate Vacuum Pressure, Torr 15 Maximum Vacuum, in. Hg 29.3 Horsepower, HP (watts) 1/5(150) Built-in adjustable vacuum Yes Gas Ballast - Head Material PTFE Diaphragm PTFE Inlet/outlet Connection 3/8” barb Agency (National Recognized Lab) CSA Weight, lbs (kg) 15.0(6.8) Overall DimensionsLxWxH in.(cm) 12x7x8.3(31x18x22) Shipping Weight, lbs(kg) 19(8.6) Shipping Carton DimensionsLxWxH in.(cm) 21x14x15(52x35x37)
$1,498.00
BVV 4 Cylinder Active Closed Loop Recovery Kit ITS/ETL to ANSI/ISA Certified
BVV 4 Cylinder Active Closed Loop Recovery Kit ITS/ETL to ANSI/ISA Certified (Pump comes with 1 yr. limited warranty) This is an Upgrade Kit which can be added to any one of our passive systems making it into an "Active" Closed Loop System. The Active Recovery Upgrade Kit will increase recovery times by condensing the vapor a lot faster than just a hot/cold differential. This will increase efficiency and productivity, many professionals use this method, as this drives profits. This Kit Includes the Following: BVV 4 Cylinder Butane Recovery Pump ITS/ETL to ANSI/ISA Certified BVV Large Condensing Coil 1/2" x 24" SS JIC Braided Hose (2) 1/2" x 48" SS JIC Braided Hose (2) 1/2" x 60" SS JIC Braided Hose Molecular Sieve Filter Drier BVV 5' HVAC Hose BVV Vacuum Tee RECOVER MORE WITH LESS BVV is proud to introduce our new and powerful line-up of Butane & Propane Recovery Pumps. Blending compact design with improved Gen III Pistons from RKMAC, this collection of pumps can help you recover 1lb. Butane / 0:51 Seconds! This pump Assembled in the USA and all the critical parts are domestically made. Finding parts wont be an issue with this pump. The piston seals are rated to 450F and the average operating temperature of the pump is 175F leading to a long service life. Certified by ITS/ETL to ANSI/ISA 12.12.01 for Use in Hazardous locations Class I & II, Division 2 and Class III, Divisions 1 & 2 environments. The computer controlled brushless DC motor operates at 3000 RMP nearly twice as fast as any other pump in its class. BVV Butane/Propane Recovery Pumps are: Process up to 10,000 lbs. of vapor recovery before rebuild Equipped with oil-less reciprocating compressors for a clean product Designed and Assembled in the U.S.A. with domestic and global parts Affordable and highly cost efficient Available in 2-Cylinder, 4-Cylinder, CMEP Retrofit Comes with a 1-year Manufacturer’s Warranty covering Hemp usage Rated universal voltage 100-240V AC 50/60 Hz 1Ph Built with high efficiency Brushless DC Motor used for variable speed control Equipped with Viton O-Ring Seals for Butane/Propane gas and oil compatibility Certified by ITS/ETL to ANSI/ISA 12.12.01 Noise level: 93.0 dB @ 1m *Butane recovery results were achieved on a collection base pressure greater than 30psi and using a recovery cylinder with a pressure <10psi. A dry ice coil was used in between the output port of the pump and the recovery cylinder to condense vapor.
$2,500.00
Huber CC-315B with Pilot ONE
Huber CC-315B with Pilot ONE (Lead time may vary.) Heating bath circulation thermostats with a stainless steel bath allow the temperature control of internal and external thermoregulation tasks. Items can be directly thermoregulated by placing them in a thermostat bath and the control of externally connected applications is also possible. The units are suitable for a number of typical temperature control tasks such as sample temperature control, materials testing, quality control, etc. The devices are fitted with overtemperature and low-level protection in line with Safety Class III/FL according to DIN 12876. A powerful pressure/suction pump ensures optimal circulation and temperature homogeneity in the thermostat bath and also allows temperature control of externally connected applications. The new multi-touch controller Pilot ONE offers a brilliant 5.7" touchscreen with graphic functions and a comfortable navigation menu. All important operating parameters and temperature values are neatly displayed on the touchscreen. Thanks to the new favorites menu, the one-click operation, and the integrated technical glossary the operation is very easy, just like on a smartphone. Integrated USB and Ethernet ports allows connection to a PC or network, e.g. for remote control or data transmission. Pilot ONE controller with Plug & Play technology Precise temperature control 5.7“ touchscreen and comfortable menu navigation Overtemperature and low level protection Safety class III/FL (DIN 12876) Powerful pressure/suction pump Programmer with calendar and clock functions 2-point calibration RS232 interface and Pt100 connection Data Sheet Click here to see Warranty Common Specifications Temperature range (-20) 28...300 °C Temperature stability ±0.02 °C Temperature control TAC, self-optimizing (True Adaptive Control) Controller Pilot ONE (E-grade "basic") Safety class III / FL Protection class IP20 Dimensions (W x D x H) 13.19 x 15.04 x 17.05 inches Weight 48.51 pounds Heating / cooling capacity Heating capacity 3 - 3,5 kW Circulation pump Pressure pump max. 25 lpm : 0,7 bar | 6.6 gpm ; 10.15 psi Suction pump max. 18.5 lpm : 0,4 bar | bar 4.89 gpm ; 5.8 psi Pump connection M16x1 AG male Permissible viscosity 50 mm²/s Connections Pt100 connection Pt100 Digital interface RS232, Ethernet, USB Device, USB Host Operating data Old sku 2007.0003.01 Permissible ambient temp. 5...40 °C Bath opening W x D / BD 10.63 x 5.71 / 7.87 inches Bath volume 15 Liters | 3.96 gal Filling volume min. 11.5 Liters | 3.04 gal Power supply 208V 2~ 60Hz Current max. 16 A Fusing 20 A
$9,570.00 - $10,070.00
Half Ton - High Purity USA ISO-BUTANE - 99.5% Guaranteed
Half Ton - High Purity USA ISO-BUTANE - 99.5% Guaranteed DISCLAIMER(S): This unit is intended for LEGAL purposes only, to be used in accordance with local laws and ordinances. Use only in WELL VENTILATED AREAS! Notice: This item will ship via Freight ONLY. This tank requires a CGA 510 fitting - Sold Separately BVV™ always recommends distillation of every solvent before use. *Actual liquid weight is 490LB California now prohibits the retail sale of any Non-Odorized butane in quantities larger than 150ml. If you are not a retail purchaser you can call in to place an order. Permitted Sales Include the Following: Medical Collectives or Cooperatives operating under CA Health & Safety Code Section 11362.775 Persons licensed to perform volatile solvent extraction activity under CA Bus & Prof Code Division 10 Manufacturers, wholesalers, resellers, or retailers solely for the purpose of resale At BVV™, quality is everything, and our ISO-Butane is certainly no exception. This ISO-Butane is sourced here in the U.S, so you know it’s going to be of high purity: we guarantee 99.5% purity. With such high quality, you’ll see the results. By cutting down on mystery oils and other contaminants, our instrument-grade solvent will make for a higher quality extract. This solvent is clean, odorless, and colorless, meaning there are zero hydrogen sulfide-based Ethyl Mercaptan odorants. It’ll arrive in a DOT refillable LP tank, equipped with liquid withdrawal valve (Diptube). Made to keep you going for a long time. Typical Analysis: ISO-Butane >99.8% Methane <1 ppm Ethane <1ppm N-Butane <2000 ppm Propane <250ppm Isopentane <2 ppm Water <3 ppm Oxygen <5 ppm Nitrogen <10 ppm Sulfur Non-Detected **Notes: Actual ISO-butane liquid weight is 490LB BVV™ always advises distillation of every solvent before using it. DISCLAIMER: Our items are intended for LEGAL purposes only, to be used in accordance with local laws and ordinances. For safe operation, only use the unit in well-ventilated areas. ***Shipping Notes: This item will ONLY ship via UPS Ground, in accordance with FAA regulations. Any orders including solvent will NOT be shipped Expedited. If an order includes solvent as well as additional items, it will all be shipped via UPS Ground/Freight even if you’ve selected Expedited. If you want the non-solvent item to ship Expedited, place 2 separate orders; we won’t split up orders and ship them separately otherwise. We do not ship solvents to Hawaii, Puerto Rico, or any other U.S. Territory outside of the contiguous 48 States. Shipping solvent to Alaska will ONLY be via freight and will be required to travel through Canada. Our shipping policies are in place to ensure safe transport of solvents and prevent any problems with shipping times for Best Value Vacs customers
$2,950.00
160L Jacketed Stainless Steel Centrifuge with Explosion Proof Motor and Siemens Controller - 55LB Max Capacity
160L Ethanol Wash/Dry Centrifuge with Explosion Proof Motor and Controller Notice to Customer: This unit has 4 lift points (one in each corner) and requires a forklift to lift it. It will also ship via freight only. Industrial Centrifuges are used to separating liquids from solids and this style of centrifuge excels at alcohol extraction by forcefully separating the alcohol from the biomass. Key Features: Siemens Touch Screen Controller Explosion Proof Controller Housing and Motor Agitation and Spin Dry Modes Max 1200 RPM with Gradual Speed Stepping 643 Separation Factor Multiple Connection Ports/Sizes High Polish Stainless Steel Components Shock absorbing legs Vacuum Jacket with Two 1" Tri-Clamp Fittings Pre-wired and Tested for Easy Installation Specifications Capacity 160L Drum Dimensions 31.5" (800mm) Diameter x 12.6" (320mm) Depth Speed 0-1200r/min Weight 3307lbs (1500KG) Exterior Dimensions 51.2" x 72.8" x 43.3" (1300 x 1850 x 1100mm) Material 304 Stainless Steel Motor Power 7.5KW Explosion Proof - 220v 60Hz 3 Phase
$32,500.00
Heavy Duty Steel Mobile Cart for Vacuum Ovens
Heavy Duty Steel Mobile Cart for Vacuum Ovens Our heavy-duty cart is designed and built to house a variety of equipment such as vacuum ovens, cold traps, vacuum pumps, etc. The cart can comfortably house up to 3 BVV™ and Across International 0.9 and 1.9 vacuum ovens. The cart offers mobility with their swivel caster wheels and can withstand up to a total of 1,100lbs. Included in the unit are three side shelves in which the height can be adjusted to your needs. The cart was meticulously designed for reliability, customization, and convenience for your process. Features: White powder coated carbon steel. 3-shelf shelving unit 3 laser cut, height adjustable side shelves. 2⅜” diameter hole to help with hose and cable management. 6” front lip for easy oil drainage. Can fit on the left or right side of the bracket Four 3” swivel caster wheels: 2 with brakes and 2 without brakes. Dimensions: 33” (L) x 23” (W) x 61” (H). Additional 13¼” to the length with side shelves added. Made in the USA. Note: The unit shipped does NOT come with the side shelves assembled. Required tool: 5mm ball hex (NOT INCLUDED).
$1,490.00
20L Neocision Dual Head Short Path Distillation Kit
20L Neocision Dual Head Short Path Distillation Kit This unit carries a 2 day lead time. (Note: This kit does NOT include the stainless steel table.) The 20L Neocision Distillation Kit Setup features our Dual P10V6 Distillation Heads and USA made glass. Every component in this distillation kit is made for precision, throughput, and repeatable results. You will also receive Dual Dewar Style Ribbed Glass Cold Traps to keep all volatiles and solvents out of your vacuum system. This kit gives you the essentials of a short path distillation system and allows you to add a pump and temperature control system of your choosing. The 20L Neo Kit Includes: 20L Neocision Kit with glassware, labware, and Dual P10V6 Distillation Heads. KF-25 Bellow Y Manifold Dual Ribbed Dewar Style Glass Cold Trap Non-Mercury Glass Thermometers 20L Digital Heating and Stirring Mantle Distillation Quick Start Guide This guide gives basic quick start instructions for distillation systems. It is intended to provide a starting point for learning the process. Parameters should be adjusted to suit specific needs, Before beginning distillation, ensure the following steps have been taken: Vacuum Pump is in good working order. Pump should be run against dry load to allow internals to warm up. Oil should be clear. Cloudy or dark oil should be changed. All glass components are in good working order and ready to be assembled A winterization and degassing procedure has been done to prepare oil for distillation The unit's max internal temperature cannot exceed 380C. The recommended max set temperature should not exceed 250C Once all three of these steps have been completed, you are ready to begin distilling. Begin by placing stir bar in the boiling flask and then load your material. This should be done using a funnel. A small amount of alcohol in the oil will give it a thinner consistency making it easier to transfer. Assemble all glassware and ensure each joint is properly greased. Do not use too much, as the vacuum pressure might pull some grease into the system. To ensure a full seal, spread grease in a circular motion by rotating glassware Attach circulator to condenser and set temperature to 50C. Allow circulator to reach temperature before beginning distillation. Connect vacuum pump to manifold. The manifold will allow you to isolate each individual component as well as let atmosphere into and out of the system. Connect receiving cow to cold trap. Connect cold trap to manifold. Connect vacuum gauge to manifold. At this point, ensure all connections are correct. Also ensure receiving cow is positioned to collect the first fraction in the far-left receiving flask. Circulator should be at its set temperature. Turn on vacuum pump to begin process. Turn on heat and set to 60C. Vacuum pump will begin to pull down and temperature will begin to rise. Watch the gauge to monitor vacuum pressure and stability. Start stir slower and increase speed with temperature. Once you are close to 60C, increase the temperature 20 degrees. Continue to raise the heat incrementally in 20-degree steps, increasing the set temperature as you near your set point. Increase temperatures incrementally until you reach 220C. You will see your first fraction somewhere between 180C and 190C or slightly before. This is the “heads” fraction. You will move to your second fraction when you see an increased reaction in the head, a slight color change toward golden, as well as a thickening of distillate. When this fraction hits, allow the distillate to “self-clean” the head for a minute or two then, rotate the cow to the middle receiving flask. Collect your “main body” fraction. You will see temps between 190-220C during this fraction. Continue to increase stirring speed as necessary. Reaction in the head may vary but it should never stop. As fluid level in the boiling flask decreases, increase stir speed. The final “tails” fraction is a mixture of the first and second fractions and should be saved for re-distillation later. Ideally, you want to turn the cow to the final flask before the tails fraction hits. The “tails” fraction has an obvious color change and will be darker than the “main body” fraction. You will see temps between 200-250C during this fraction. As fluid level in the boiling flask decreases even more, set stirring RPM higher (1000+ RPM). You may need to compensate with a bit more heat to finish of the final fraction as well. Once process is complete, stop heat, stop stir, and stop vacuum. Let atmosphere into the system. Be sure to properly store your distillate as exposure to air and light can cause oxidation. *Note: This entire setup will ship via motor freight.*** *Notice to Customers: All units are inspected for broken glassware or parts before leaving BVV™. If the unit arrives damaged (this does not include minor imperfections or scuffs in glassware), the customer MUST contact BVV™ within 72 hours from carrier delivery to file a claim. If the customer DOES NOT contact BVV™ within 72 hours from carrier delivery, then BVV™ cannot issue any replacement(s) or compensation for the item; a new purchase will need to be made for a replacement. BVV™ is not responsible for the failure of glassware which must be inspected before and after every use because it may eventually develop imperfections or damage through normal usage, mishandling, and stress caused by temperature variations. If an imperfection or damage is noted while inspecting the glassware DO NOT use the glassware because it can fail, which can cause bodily harm or damage to the surrounding area.
$6,800.00 - $7,000.00
Welch BTpro170
Welch BTpro170 ***Note: This item has a possible lead time of 2-3 weeks depending on stock availability.*** Welch’s BTpro vacuum pump series has a flow and vacuum level to provide fast performance for your size of rotary evaporator, glass reactor, purge oven, or winterization filtration apparatus. These chemical duty PTFE diaphragm pumps are oil-free. The pumping action and deep vacuum comes from the movement of PTFE diaphragms within PTFE heads. All wetted services in the flow path are made of fluoroplastic making the BTpro pump highly chemically resistant. As a result, the BTpro vacuum pump series is near-zero maintenance. A cold trap placed in-line with BTpro pump is needed if terpenes are part of the flow path. Model BTpro170 2163 Free Air Displacement@60Hz,lpm(CFM) 170 (6.0) 170 (6.0) Ultimate Vacuum Pressure, Torr 6 6 Maximum Vacuum, in. Hg 29.7 29.7 Horsepower, HP (watts) 0.6(440) 0.6(440) Built-in adjustable vacuum - - Gas Ballast Yes Yes Head Material PTFE Coated Al Diaphragm PTFE PTFE Inlet/outlet Connection NW16 flange NW16 flange Agency (National Recognized Lab) cUL cUL Weight, lbs (kg) 72.3 (32.8) 72.3 (32.8) Overall DimensionsLxWxH in.(cm) 21x11x12(53x28x31) 21x11x12(53x28x31) Shipping Weight, lbs(kg) 88.2 (40.1) 88.2 (40.1) Shipping Carton Dimensions LxWxH in.(cm) 23.6x15.8x16.1 60x40x41 23.6x15.8x16.1 60x40x41
$4,349.00
4" Wiped Film Evaporator (WFE) Distillation Turn Key System - USA MADE
4" BVV Wiped Film Evaporator This system has a 1-2 week lead time. The BVV™ 4" Wiped Film Evaporator (WFE) is a full turnkey distillation kit that will will allow anyone to run a molecular distillation. With the magnetically driven wiper and high vacuum seals this system is able to achieve vacuum levels below 10 mtorr. The system has multiple temperature control apparatuses that allow the user to dial in specific settings that works best for their application. The maximum operating temperature of the outer jacket is 200°C with the standard circulators shown below. The maximum feed rate is up to 7LPH. On average, you can expect to flow 500-1000ml per hour. All heated circulators can be tailored to your specific needs, just ask our team of experienced account representatives! The temperature controlled circulators will need thermal fluid that corresponds with the temperatures needed. Click here to browse fluids. *Heating and Chilling Fluids are not included* Duratherm S - 7 Gallons - Bottom heater (wiper body) Therminol XP Heat Transfer Fluid - 5 Gallons - Top and middle heater *Propylene Glycol - 5 Gallons - Fluid for the diffusion pump option chiller. Ethanol 99% or Isopropyl 99% - 2 Gallons - Cold Trap / Cold Finger. For a full list of ancillary equipment included in the kits please see the table below: KIT Part of System Component Electrical Requirements (V / Ph / A) WFE04-TK-01 Standard Model Wiper Assembly BVV™ Stirring motor 120V / 1Φ Vacuum System BVV™ Pro Series 35.3CFM Rotary Vane Vacuum Pump* DigiVac Bullseye Precision Vacuum Gauge 220V / 3Φ AA Batteries (4x) Temperature Controlled Circulators Polyscience 7L Polyscience 15L (2x) 120V / 1Φ / 10A 220V / 1Φ / 10A Injection Beaker and Wrench 7LPH Peristaltic Heated Hose 120V / 1Φ 120V / 1Φ WFE04-TK-02 Upgraded Vacuum System Upgraded Cold Trap Wiper Assembly BVV™ Stirring motor 120V / 1Φ Vacuum System BVV™ Pro Series 35.3CFM Rotary Vane Vacuum Pump* Summit Research Diffusion Pump (SR-DP04A)** DigiVac Bullseye Precision Vacuum Gauge 220V / 3Φ 180/264V / 1Φ / 10.5A AA Batteries (4x) Temperature Controlled Circulators Polyscience 7L Polyscience 15L (2x) 120V / 1Φ / 10A 220V / 1Φ / 10A Injection Beaker and Wrench 7LPH Peristaltic Heated Hose 120V / 1Φ 120V / 1Φ Cold Trap Polyscience IP100 120V / 1Φ / 11.5A WFE04-TK-03 Upgraded Vacuum System Upgraded Cold Trap Outlet Pumps Wiper Assembly BVV™ Stirring motor 120V / 1Φ Vacuum System BVV™ Pro Series 35.3CFM Rotary Vane Vacuum Pump* Summit Research Diffusion Pump (SR-DP04A)** DigiVac Bullseye Precision Vacuum Gauge 220V / 3Φ 180/264V / 1Φ / 10.5A AA Batteries (4x) Temperature Controlled Circulators Polyscience 7L Polyscience 15L (2x) 120V / 1Φ / 10A 220V / 1Φ / 10A Injection Beaker and Wrench 7LPH Peristaltic Heated Hose 120V / 1Φ 120V / 1Φ Cold Trap Polyscience IP100 120V / 1Φ / 11.5A Outlet Pumps Beaker and Wrench Gear Pump (2x) Beaker and Wrench Heat Pad PID Controller 120V / 1Φ 120V / 1Φ Notes: *The Rotary vane vacuum pump paired with this kit uses 3Φ power, a smaller single phase pump can be substituted if needed. Substitution will have an impact the performance versus the standard unit. **The Summit Research diffusion pump must be water cooled, if facility water cooling is not an option an additional chiller may be needed, a Polyscience 1HP Durachill is recommended. An air cooled diffusion pump can be provided as a substitute. Substitution will have an impact the performance versus the standard unit.
$45,000.00 - $76,000.00
2L BVV™ Rotary Evaporator Turnkey Setup
2L BVV™ Rotary Evaporator Turnkey Setup 2L Electric Lift Rotary Evaporator turnkey setup includes all the necessary components to successfully perform solvent recovery via rotary evaporation. A cold trap should always be used inline between your vacuum system and application to protect the pump from volatile vapors. 2L Rotary Evaporator Turnkey Setup includes: 2L Electric Lift Rotary Evaporator 90-day limited warranty (excludes glassware, consumables & moving parts) BVV NEO 1.4 CFM Diaphragm Pump ETL Rated OR. 3.5CFM Dry Floating Scroll Vacuum Pump Polyscience LS -20C to 40C 1/2HP Chiller w/ Turbine Pump OR BVV NEOCISION 20L Chiller (-40C) - ETL Rated 10ft of Vacuum Tubing 20ft of Chiller Tubing 10 Pack of Adjustable stainless steel hose clamps 3/8" Vacuum Manifold Optional add-on : BVV™ CT40 -40°F 300ml x 3 Cold Trap, BVV™ CT80 -112°F 300ml x 3 Cold Trap Optional add-on: J-KEM DVR-200 Digital Vacuum Regulator Optional add-on: Heat Transfer Fluid -- NuTherm PF-50 or Dynalene HC-50 Rotovap Quick Start Guide This guide gives basic quick start instructions for rotovaps. It is intended to provide a starting point for learning the process. Parameters should be adjusted to suit specific needs. Clean and assemble unit. Make sure all pieces are cleaned and sterilized using an alcohol solution. Connect chiller to the condenser and set to 0C (32F). Always fill a rotovap condenser from the top down (chiller output to top of the condenser, chiller input to bottom of the condenser). Connect vacuum pump to cold trap and connect cold trap to the vacuum port on rotovap. Turn on heat bath and set to 40C (113F). Once heat bath, chiller, and cold trap have reached desired temperatures, turn on the rotovap motor and set the speed to approximately 100 RPM (does not have to be precise). Keep in mind, higher RPM’s will increase evaporation power but also increase heat load. Start vacuum pump and allow vacuum to pull down for a few minutes before injection. Once the vacuum has been pulled to a sufficient level (does not have to be precise but should be below 100 Torr), using the injection valve, very slowly inject approximately 500 mL of solution into evaporating flask and then close the valve. Allow this small amount to begin evaporating. You may see the chiller begin to rise in temperature, this is called “priming” the rotovap. Once the temperature stops rising or all liquid is almost completely evaporated, open the injection valve again very slowly so that a small amount of liquid begins to enter the evaporating flask. Do not close injection valve this time but continue to allow the solution to enter the evaporating flask. At this point, you must try to match the input speed to the output speed. What this means is that you should be injecting the same amount of liquid into the rotovap that is equal to the amount of liquid dripping from the condenser into the receiving flask. You will know that the input speed and output speed are matched because the chiller will remain at a stable temperature. If the chiller begins to rise, then you are injecting too much liquid. Dial back the valve until the chiller stabilizes. Once everything is stabilized, you may walk away from the rotovap if necessary. Check every so often to make sure temperatures remain stable and evaporation continues efficiently. ***Glassware Safety Disclaimer: BVV™ is not responsible for failure of glassware which must be inspected before and after every use because it may eventually develop imperfections or damage through normal usage, mishandling, and stress caused by temperature variations. If an imperfection or damage is noted while inspecting the glassware DO NOT use the glassware because it can fail causing bodily harm or damage to the surrounding area.***
$7,000.00 - $13,500.00
10L Premium Short Path Distillation Kit with P10 Distillation Head
10L Short Path Distillation Kit with P10 Distillation Head This unit carries a 2 day lead time. (Note: Stainless Steel Table NOT Included.) The 10L Short Path Distillation Kit features our USA made P10 Distillation Head. Every component in this turnkey is made for precision, throughput, and repeatable results. Also included the Kangaroo digital thermometer which is very rugged and reliable. You will also receive a Ribbed Dewar Style Glass Cold Trap to keep all volatiles and solvents out of your vacuum system. This Kit gives you the basic necessities of a short path distillation system and allows you to add on a temperature control system and vacuum pump to fit your needs. The 10L Neo Kit Includes: 10L Short Path Distillation Kit including glassware, labware, and P10 Distillation Head. 10L Digital Heating and Stirring Mantle. Valved Vacuum Adapter. Ribbed Dewar Style Glass Cold Trap. Kangaroo Digital Thermometer. Distillation Quick Start Guide This guide gives basic quick start instructions for distillation systems. It is intended to provide a starting point for learning the process. Parameters should be adjusted to suit specific needs, Before beginning distillation, ensure the following steps have been taken: Vacuum Pump is in good working order. Pump should be run against dry load to allow internals to warm up. Oil should be clear. Cloudy or dark oil should be changed. All glass components are in good working order and ready to be assembled A winterization and degassing procedure has been done to prepare oil for distillation The unit's max internal temperature cannot exceed 380C. The recommended max set temperature should not exceed 250C Once all three of these steps have been completed, you are ready to begin distilling. Begin by placing stir bar in boiling flask and then load your material. This should be done using a funnel. A small amount of alcohol in the oil will give it a thinner consistency making it easier to transfer. Assemble all glassware and ensure each joint is properly greased. Do not use too much, as the vacuum pressure might pull some grease into the system. To ensure a full seal, spread grease in a circular motion by rotating glassware Attach circulator to condenser and set temperature to 50C. Allow circulator to reach temperature before beginning distillation. Connect vacuum pump to manifold. The manifold will allow you to isolate each individual component as well as let atmosphere into and out of the system. Connect receiving cow to cold trap. Connect cold trap to manifold. Connect vacuum gauge to manifold. At this point, ensure all connections are correct. Also ensure receiving cow is positioned to collect the first fraction in the far-left receiving flask. Circulator should be at its set temperature. Turn on vacuum pump to begin process. Turn on heat and set to 60C. Vacuum pump will begin to pull down and temperature will begin to rise. Watch the gauge to monitor vacuum pressure and stability. Start stir slower and increase speed with temperature. Once you are close to 60C, increase the temperature 20 degrees. Continue to raise the heat incrementally in 20-degree steps, increasing the set temperature as you near your set point. Increase temperatures incrementally until you reach 220C. You will see your first fraction somewhere between 180C and 190C or slightly before. This is the “heads” fraction. You will move to your second fraction when you see an increased reaction in the head, a slight color change toward golden, as well as a thickening of distillate. When this fraction hits, allow the distillate to “self-clean” the head for a minute or two then, rotate the cow to the middle receiving flask. Collect your “main body” fraction. You will see temps between 190-220C during this fraction. Continue to increase stirring speed as necessary. Reaction in the head may vary but it should never stop. As fluid level in the boiling flask decreases, increase stir speed. The final “tails” fraction is a mixture of the first and second fractions and should be saved for re-distillation later. Ideally, you want to turn the cow to the final flask before the tails fraction hits. The “tails” fraction has an obvious color change and will be darker than the “main body” fraction. You will see temps between 200-250C during this fraction. As fluid level in the boiling flask decreases even more, set stirring RPM higher (1000+ RPM). You may need to compensate with a bit more heat to finish of the final fraction as well. Once process is complete, stop heat, stop stir, and stop vacuum. Let atmosphere into the system. Be sure to properly store your distillate as exposure to air and light can cause oxidation. ***Note: This entire setup will ship via motor freight.*** *Notice to Customers: All units are inspected for broken glassware or parts before leaving BVV™. If the unit arrives damaged (this does not include minor imperfections or scuffs in glassware), the customer MUST contact BVV™ within 72 hours from carrier delivery to file a claim. If the customer DOES NOT contact BVV™ within 72 hours from carrier delivery, then BVV™ cannot issue any replacement(s) or compensation for the item; a new purchase will need to be made for a replacement. BVV™ is not responsible for the failure of glassware which must be inspected before and after every use because it may eventually develop imperfections or damage through normal usage, mishandling, and stress caused by temperature variations. If an imperfection or damage is noted while inspecting the glassware DO NOT use the glassware because it can fail, which can cause bodily harm or damage to the surrounding area.
$4,100.00
ASME Certified 50L Jacketed Solvent Tank 304L - Bare
ASME Certified 50L Jacketed Solvent Tank 304L - Bare This is a custom manufactured USA made ASME Certified 50LB Jacketed Collection base with UM Stamp and made out of 304L Stainless Steel. This base is designed to be configured to any application and can even be used as a solvent tank. This tank comes bare with no fittings and will hold around 50LBS of liquid butane and is able to have fluid circulated around the outer jacket to increase recovery speeds in the extraction system. **This Item will ship Via FREIGHT ONLY. Specifications Material 304L Stainless Steel Certification: ABILITY ENGINEERING TECHNOLOGY INC. ASME / UM / NB MAWIWP 350 PSI at 150°F MAWEWP N/A MIN TEMP -20°F at 350PSI Butane Capacity ~50LBS Connection Sizes: 6" Tri-Clamp (2) 1" NPT (2) 1/2" NPT - Outer Jacket Ports (2) 3/8" NPT Weight 146LBS Outer Dimensions: 32-7/8" Tall 14" Diameter Inner Dimensions: 24" Tall 12" Diameter
$3,500.00
ASME 150L - 350 MAX working pressure, Pneumatic PSIG 385
ASME 150L - 350 MAX working pressure, Pneumatic PSIG 385 This is a custom manufactured made ASME Certified 150L Jacketed Solvent Tank with ASME Stamp and made out of 304 Stainless Steel. This base is designed to be configured to any application and can even be used as a solvent tank. This tank comes bare with no fittings and will hold 150LBS of liquid butane and is able to have fluid circulated around the outer jacket to increase recovery speeds in the extraction system. This unit also has welded lift points on the top of the tank. Specifications Material 304 Stainless Steel Certification: ASME MAWP @ 100°C / 212°F: Inside 350 PSI / 2.42 MPa Jacket 150 PSI / 1.1 MPa MDMT -40°C / -40°F MIN TEMP -20°F at 350PSI Butane Capacity 150LBS Connection Sizes: (3) 6" Tri-Clamp (2) 1.5" Tri-Clamp (2) 1/2" FNPT Weight 108LBS Outer Dimensions: 44.5" Tall 32.5" W x 32.5" L **This Item will ship Via FREIGHT ONLY.
$8,000.00
Welch CRVpro Direct Drive Rotary Vane Vacuum Pump CRVpro4
Welch CRVpro Direct Drive Rotary Vane Vacuum Pump CRVpro4 ***Note: This item has a possible 1-2 week lead time depending on stock availability*** Product Details The new CRVpro family of direct drive vacuum pumps offers increased reliability and longer service interval vs. other direct drive rotary vane vacuum pumps. The CRVpro family consumes up to 36% less oil than comparable pumps. Three features drive these benefits: Runs 10°C cooler than comparable pumps. Slows corrosion. Has a 40% larger oil capacity than comparable pumps. Dilutes aggressive chemicals. Has a chemical resistant coating in the oil case and pump module. Protects non-moving parts. The CRVpro family includes all the features you'd expect in a direct drive rotary vane pump: gas ballast, forced oil lubrication, anti-suckback mechanism and thermal overload protection. Suitable applications include freeze drying, degassing, vacuum ovens and concentrators. 3041-01 is wired for North American 115V, 60Hz operation. Includes North American line cord, vacuum inlet hose barb suitable for gum rubber hose from 5/8" to 3/4" ID, and a charge of oil. 3042-01 is wired for North American 230V, 60Hz operation. Includes 230V North American line cord, UK cord, and skuko cord, and a charge of oil. 3046E-01 comes with an explosion proof motor. Conduit wiring installation required. No cord, plug, or switch provided. Direct drive pumps are not recommended for filtration, aspiration, drying electrophoresis gels, or other applications requiring sustained operation above 30 torr. Specifications Applications CRVpro4 Free Air Displacement @ 60 Hz, cfm (L/min) 2.8 (78) Free Air Displacement @ 50 Hz, m³/hr (L/min) 4 (67) Ultimate Pressure, torr (mbar) 5x10⁻⁴ (4x10⁻⁴) Noise Level, dBA 50 Motor Speed, RPM, @60Hz, @50Hz 1740 (1450) 1750 (1450) Motor Power, HP (kW) 0.4 (0.5) Oil Capacity, mL 1150 Connection Flanges NW 16 Inlet Hose Connection* 5/8" to 3/4" Weight, lbs (kg) 46.3 (21) Dimensions, LxWxH, in (mm) 18.2x6.1x9.1 (463x157x230)
$2,810.00
Master Vapor MVP Liquid Recovery Pump
Master Vapor MVP Liquid Recovery Pump THE NEW LIQUID Pumps solvent in liquid state Hydrocarbon and ethanol compatible C1D1 and 3rd party Certified Drastically increases evaporation byexpanding surface area andcreating turbulence Electric Driven FDA Food Grade Compliant MADE IN THE USA Engineering Specifications: Maximum pumping outlet pressure - 70 PSI Center Section CO2 charge range 5 to 80 PSI(10-15psi over inlet pressure recommended) CO2 Inlet Size: 1 /4 in. npt(f) Maximum Pump Speed 135 cpm (cycle per minute) Process Inlet and Outlet Size: 1 in. npt Electric Motor: Explosion proof for C101 Hazardous areas Motor Specifications: 2HP, 3,600 rpm, 60Hz Size: 18.3” x 15.4” base x 42.3” tall Weight: 173.2 lb All sales final Technical Data sheet US Metric Maximum Pumping outlet Pressure 70 PSI 0.48 MPa, 4.8 bar Center section CO2 Change range 6 to 80 PSI 0.03-0.55 MPa 0.3-5.5 bar Equipment Withstand Pressure 350 PSI 2.41 MPa, 24.1 bar Maximum CO2 Consumption <0.2 scfh <0.006 cubic meters/hour CO2 inlet size 1/4 in. npt(f) Maximum Pump Speed 135 cpm Process intel and outlet size 1 in. npt Model MVP Liquid, 3 ph, Inverter Rated Power 2 HP 1.5kW Speed 3600 rp, (60 Hz) Gear Ratio 25.85 Voltage 1-phase 208-230/460V Maximum Amperaage Load 5.2 A (230V / 2.6 A (460V) Model MVP Liquid 1PH Power 2 HP 1.5kW Speed 3600 rpm (60 Hz) Gear Ratio 25.85 Maximum Amperaage Load 5.2 A (115V / 10 A (230V) Noise Data Sound Power (measured per ISO-9614-2 88.5 dBa Sound Pressure {Tested 3.28ft (1m) From Equipment} 80.5dBa Materials Process Pressure Section and Reed Valves Stainless Steel Diaphragms Standard: FKM Fluoroelastomer Optional:PTFE Process Vapor Temperature Range FKM: -40 to 275 °F (-40 to 135 C)PTFE: +40 to 220 °F 9+4 to 104 C
$13,700.00 - $14,250.00
36 inch Filtration Funnel V2
Buchner Filtration Kit This filtration kit is operated by using a vacuum pump to pull the solution through the filter paper to remove particulate. The funnel has a 36" perforated plate to support the filter paper.
$6,320.00 - $6,900.00
20L Neocision ETL Lab Certified Rotary Evaporator Turnkey System
20L Neocision ETL Lab Certified Rotary Evaporator Turnkey System 20L NEO Rotary Evaporator Turnkey System setup includes all the necessary components to successfully perform solvent recovery via rotary evaporation. A cold trap should always be used inline between your vacuum system and application to protect the pump from volatile vapors. 10-50L NEO and ECO Rotary Evaporator Diagram 20L NEO Rotary Evaporator Turnkey System setup includes: 20L Neocision ETL Lab Certified Rotary Evaporator Polyscience 6160T 1HP Chiller 3/8" Gum Rubber - 100ft 3/8" Silicone Tubing - 25ft Welch BTpro100 Diaphragm Pump Adjustable Stainless Steel Hose Clamps Rotovap Quick Start Guide This guide gives basic quick start instructions for rotovaps. It is intended to provide a starting point for learning the process. Parameters should be adjusted to suit specific needs. Clean and assemble unit. Make sure all pieces are cleaned and sterilized using an alcohol solution. Connect chiller to condenser and set to 0C (32F). Always fill a rotovap condenser from the top down (chiller output to top of condenser, chiller input to bottom of condenser). Connect vacuum pump to cold trap and connect cold trap to vacuum port on rotovap. Turn on heat bath and set to 40C (113F). Once heat bath, chiller and cold trap have reached desired temperatures, turn on rotovap motor and set speed to approximately 100 RPM (does not have to be precise). Keep in mind, higher RPM’s will increase evaporation power but also increase heat load. Start vacuum pump and allow vacuum to pull down for a few minutes before injection. Once vacuum has been pulled to a sufficient level (does not have to be precise but should be below 100 Torr), using the injection valve, very slowly inject approximately 500 mL of solution into evaporating flask and then close the valve. Allow this small amount to begin evaporating. You may see the chiller begin to rise in temperature, this is called “priming” the rotovap. Once the temperature stops rising or all liquid is almost completely evaporated, open the injection valve again very slowly so that a small amount of liquid begins to enter the evaporating flask. Do not close injection valve this time but continue to allow solution to enter the evaporating flask. At this point you must try to match the input speed to the output speed. What this means is that you should be injecting the same amount of liquid into the rotovap that is equal to the amount of liquid dripping from the condenser into the receiving flask. You will know that the input speed and output speed are matched because the chiller will remain at a stable temperature. If the chiller begins to rise, then you are injecting too much liquid. Dial back the valve until the chiller stabilizes. Once everything is stabilized, you may walk away from the rotovap if necessary. Check every so often to make sure temperatures remain stable and evaporation continues efficiently. ***Note: All units are inspected for broken glass or parts before unit is shipped. If unit arrives damaged or glass is broken (this does not include minor imperfections or scuffs in glassware), Customer MUST contact BVV™ within 3 days of delivery to file a claim and receive a replacement part. If customer DOES NOT contact BVV™ within 3 days of delivery responsibility for replacement parts falls on the customer and they must pay for replacement pieces.*** ***Note: This item will ship by freight only.*** ***Glassware Safety Disclaimer: BVV™ is not responsible for failure of glassware which must be inspected before and after every use because it may eventually develop imperfections or damage through normal usage, mishandling, and stress caused by temperature variations. If an imperfection or damage is noted while inspecting the glassware DO NOT use the glassware because it can fail causing bodily harm or damage to the surrounding area.***
$14,750.00 - $17,305.00
Side Mount Tri-Clamp Filter Strainer
Side Mount Tri-Clamp Filter Strainer Tri Clamp strainers are used for filtration of solids from fluid process flows. It is recommended that a strainer be placed before a pump when emptying a centrifuge and the like to not allow large solids to enter and damage a pump. Side Mount Inline Strainers Tri Clamp inline strainers mount similar to a spool or elbow with both ends clamped into a tri-clamp fitting. The side mount strainer has a unique characteristic, it can be emptied while still attached just by removing the internal basket as long as it is correctly mounted. Liquid should flow in through the side port and out through the bottom port.
$190.00
Polyethylene Glycol 400 - PEG 400
Polyethylene Glycol 400 Polyethylene glycol 400 has an average molecular weight of 400. It is a clear, viscous liquid at room temperature. APPLICATIONS • Chemical Intermediate• Plasticizer• In cosmetics for preparation of ointments and lotions.• As a mold release agent and lubricant for both natural and synthetic products. Physical Properties Flash point, PMCC, °F 390 Flash point, PMCC, °C 199 Refractive index, 25°C 1.463 Density, g/ml, 20°C (68°F) 1.1254 Weight, lbs/US gal, 20°C (68°F) 9.39 Freezing Range, °F 39-46 Freezing Range, °C 4-8 Viscosity, kinematic cSt at 25°C (77°F) 84 cSt at 98.9°C (210°F) 7.3 Chemical Properties Molecular Weight (range) 380-420 Average number of EO units 8.7 Water Solubility Soluble Potassium acetate, wt% 0.02-0.2 pH, 5% aqueous solution 4.5-7.0 Water, wt% 0.5 max. Color, Pt-Co 50 max. Hydroxyl number, mg KOH/g 267-295 Appearance, 20°C Clear The expiration date is 3 years from the date of manufacture and when the glycol is kept below 100F and out of direct sunlight.
$30.00 - $5,400.00
Polyscience Durachill Chiller; 4.2 L; 208/230 V
Polyscience Durachill Chiller; 4.2 L; 208/230 V PolyScience CA10A3T1-41AA1N Offers Features: Large, full-color touchscreen display with intuitive interface and support for five different languages Home screen simultaneously displays set temperature, actual temperature, fluid pressure, fluid level, air filter status and timer Self-changing air filter system eliminates preventative maintenance by automatically changing the filter media at user-definable intervals Continuous fluid level monitoring protects pump and prevents freezing Whispercool® noise reduction system reduces operating noise levels to the almost imperceptible levels while maintaining optimal cooling performance Reduced global warming potential through a highly optimized refrigeration system design that greatly reduces the amount of refrigerant gas needed in the chiller and allows for migration to natural refrigerants that have little or no global warming potential Self-diagnostic system compares the chiller's functionality to its operating state the day it was built to minimize operating downtime and unnecessary service calls Compact, portable design takes up less floor space Cooling at ambient temperatures as high as 30°C Components are recyclable and meet or exceed global environmental standards UV Light Biological Growth Inhibitor System eliminates the need for algaecides User-adjustable temperature, pressure, and flow rate alarms Heat up to 70°C, without additional options Front fill reservoir access Externally accessible adjustable pressure regulator valve Full color touch screen display The color touch screen display gives you all the information you need at a glance. The screen will display continuous status of set temperature, actual temperature, reservoir fill level and output pressure as well as the status of your air filter. System messages are provided in easy to read text instead of confusing error codes. Dynamic self-changing filter Preprogrammed to change its own air filter once a month for a two year period, and the change interval can be adjusted to suit your operating environment. This will dramatically reduce downtime and unnecessary service calls and relieve you of the burden of preventative maintenance on your chiller. UV light biological growth inhibitor The UV Light Biological Growth Inhibitor will continuously control biological growth in the fluid path without the need to add chemical growth inhibitors and preventing algicides from being released into the world's waterways. Front fill reservoir The chiller offers a conveniently located front fill reservoir. You no longer have to go to the back of the chiller top open to fill the reservoir. It has the fill port in the front, making it easy to access, avoiding spills and saving time. Continuous liquid level monitoring Because pump seals will fail in as little as 30 seconds of being run dry, the chiller includes a state-of-the-art capacitance liquid level sensor to protect the pump from premature failure. If the fluid level becomes low, the chiller will give you visual and audible alarms. If the fluid level reaches a point where there's a risk of pulling air into the pump, it will shut the chiller down and present another alarm. Whispercool® noise reduction This high-performance chiller utilizes noise reduction system. The Whispercool® system evaluates the demand for cooling from the application then slows the fan speed to the minimum necessary to achieve control point, making the chiller extremely quiet while maintaining optimal temperature control at the same time. Applications Heat removal Specifications Cooling Capacity At 20°C: 2.9 kWAt 10°C: 1.93 kWAt 0°C: 1 kW Fluid Temperature Range 14 to 158°F (-10 to 70°C) Temperature Stability ±0.1°C Displayable Units Temperature: °C or °FPressure: psi or kPa Pump Inlet and Outlet ½" female NPT Connectivity RS-232, USB Serial Port Emulation, USB TMC, Dry Contact On/Off/Status Selectable Operating Languages English, Spanish, French, German, Mandarin Self-Changing Air Filter Yes UV Biological Growth Inhibitor Yes Ambient Air Temperature Tracking Yes Pump Pressure Range 20 to 90 psi (138 to 689 kPa) Maximum Pump Flow Rate 3.5 gpm (13.2 lpm) Power Requirements 230 V, 60 Hz, 13.5 A Dimensions 33 x 22 x 33" (84 x 56 x 84 cm) Weight 177 lbs (80.3 kg) Data sheet Manual
$8,307.00
SSP 316 SS Straight Metering Valve 512-7-316-MVH Duolok Tube Fitting
SSP 316 SS Straight Metering Valve 512-7-316-MVH Duolok Tube Fitting FloLok® Metering Valves are designed for instrumentation, research and analytical applications where accurate control and flow rates are required. Specifications: Body Material - 316SS Connection Type 1 - Doulok Tube Fitting Connection Size 1 - 3/8 in. Connection Type 2 - Duolok Tube Fitting Connection Size 2 - 3/8 in Brand Series - 500 Series Shape - Straight Orifice - 0.125 in Handle Type - Stainless Stem Type - 10 Degree 316 Stainless Steel Packing Material - PTFE
$320.00
You have seen 192 out of 230 products