Come See Us At MJBiz Con! Booth #1828

Temperature & Vacuum Control

37 products


  • BVV™ 5L Digital Heating Mantle Probe

    BVV™ 5L Digital Heating Mantle Probe

    BVV™ 5L Digital Heating Mantle Probe This is a replacement probe for the BVV™ 5L Digital Heating Mantle. the probe measures 15.5" in length with an overall length of 60.5"

  • Stainless Steel KF-25 x Glass Jointed Adapter

    Stainless Steel KF-25 x Glass Jointed Adapter

    Stainless Steel KF-25 x Glass Jointed Adapter This Custom Built 304 Stainless Steel Adapter allows the user to adapt to a KF-25 high vacuum fitting to a 24/40 or 34/45 ground glass joint fitting to allow the user to connect a KF flanged laboratory grade vacuum pump.

  • KF-25 x KF-25 x 1/8" FNPT Adapter

    KF-25 x KF-25 x 1/8" FNPT Adapter

    KF-25 x KF-25 x 1/8" FNPT Adapter This 304 stainless steel KF-25 adapter is specifically designed for adapting Digivac Bullseye Precision Vacuum Gauges to systems with reducing and minimizing connect / leak points on the system.

    $27.00

  • Stainless Steel 24/40 x 1.5" Tri-Clamp Adapter

    Stainless Steel 24/40 x 1.5" Tri-Clamp Adapter

    Stainless Steel 24/40 x 1.5" Tri-Clamp/ Tri Clover Adapter This Custom Built 304 Stainless Steel Adapter allows the user to adapt to a 24/40 ground glass joint to a 1.5" Tri-Clamp fitting to allow the user to connect the glass joint to a Tri-Clamp system.

    $55.00

  • 4 Port Glass Vacuum Manifold with PTFE Stopcocks

    4 Port Glass Vacuum Manifold with PTFE Stopcocks

    4 Port Glass Vacuum Manifold with PTFE Stopcocks General purpose single bank vacuum manifold with 4 ports. The main tube is 1" OD with a serrated hose barb connection. Ports are 4mm PTFE stopcocks with serrated hose barb connections.   *Notice to customers: All units are inspected for broken glassware or parts before leaving BVV™. If the unit arrives damaged (this does not include minor imperfections or scuffs in glassware), the customer MUST contact BVV™ within 72 hours from carrier delivery to file a claim. If the customer DOES NOT contact BVV™ within 72 hours from carrier delivery, then BVV™ cannot issue any replacement(s) or compensation for the item; a new purchase will need to be made for a replacement.   **Glassware Safety Disclaimer: BVV™ is not responsible for failure of glassware which must be inspected before and after every use because it may eventually develop imperfections or damage through normal usage, mishandling, and stress caused by temperature variations. If an imperfection or damage is noted while inspecting the glassware DO NOT use the glassware because it can fail causing bodily harm or damage to the surrounding area.**

    $160.00

  • Non-Mercury Glass Thermometer with 10/30 Joint

    Non-Mercury Glass Thermometer with 10/30 Joint

    Non-Mercury Glass Thermometer with 10/30 Joint This non-mercury glass thermometer has a 10/30 ground glass joint and is 14" long with a temperature range of -10°C to 250°C with 1 degree increments. This thermometer is made in Germany and is Serialized and Calibrated.   *Notice to customers: All units are inspected for broken glassware or parts before leaving BVV™. If the unit arrives damaged (this does not include minor imperfections or scuffs in glassware), the customer MUST contact BVV™ within 72 hours from carrier delivery to file a claim. If the customer DOES NOT contact BVV™ within 72 hours from carrier delivery, then BVV™ cannot issue any replacement(s) or compensation for the item; a new purchase will need to be made for a replacement.  **Glassware Safety Disclaimer: BVV™ is not responsible for failure of glassware which must be inspected before and after every use because it may eventually develop imperfections or damage through normal usage, mishandling, and stress caused by temperature variations. If an imperfection or damage is noted while inspecting the glassware DO NOT use the glassware because it can fail causing bodily harm or damage to the surrounding area.**

    $99.00

  • Glas-Col K Type Thermocouple

    Glas-Col K Type Thermocouple

    Glas-Col K Type Thermocouple Glas-Col K Type thermocouple is used to measure temperatures from -50°C to 1000°C with a lead length of 72" and probe length of either 12" or 18".

    $247.00

  • Glas-Col Fabric Insulating Top

    5L Glas-Col Fabric Insulating Top

    5L Glas-Col Fabric Insulating Top This mantle helps prevent vapor condensation in the upper half of a flask during distillation of high-boiling materials. The tops are designed for use with Series M, TM, or STM mantles. They protect the flask, the solutions, and the laboratory from drafts, which would disturb the reflux ration during fractionation, from flying glass of flask implosions in high vacuum distillations, from falling objects; and, from thermal strain between top and lower half of flask during high-temperature operations. With a glass-fabric construction and laced-side opening, the elliptical hole accommodates 1-, 2-, and 3-neck flasks.

    $350.00

  • Glas-Col 12L Heating Insulation Top - 115V, 590W

    Glas-Col 12L Heating Insulation Top - 115V, 590W

    Glas-Col 12L Heating Insulation Top - 115V, 590W   Glas-Col invented the Electric Heating Mantle in 1939 and has continued to be the industry leader for Laboratory and Industrial heating ever since. Our products are known for exceptional performance, reliability and durability.   Specifications Capacity 12 L Volts 115 Watts 590

    $827.00

  • Traceable Kangaroo Thermometer - Digital

    Traceable Kangaroo Thermometer - Digital

    Digital Thermometer Traceable Kangaroo™ Thermometer comes equipped with the 42-inch probe cable in a reel-compartment pouch in the back of the unit. As a perfect “carry-around” unit, this thermometer can fit easily in any pocket, or you can use the convenient flip-open stand to place upright. The dual-range digital thermometer measures temperature in test tubes, beakers, and other scientific laboratory equipment and is especially effective for rugged applications with high-impact ABS cases. Additionally, digital thermometers can measure the temperature of many substances from air to liquids to surfaces—all electronically.  The best thing about this thermometer? It’s easy to use! Any user can record identical results with this intuitive unit. The range is –58.0 to 572°F and –50.0 to 300°C with a resolution of 0.1° (between –19.9 to 199.9°) otherwise 1° and an accuracy of ±1°C (between –30 and 250°C) otherwise ±2°C. This unit automatically captures and recalls minimum and maximum temperature readings over any time period. Its high and low alarm may be programmed in 1° increments. The alarm sounds every minute until temperature returns to non-alarm condition. Pressing the HOLD key freezes the display to record a current reading. To assure accuracy, an individually serial-numbered Traceable® Certificate is provided from its ISO 17025 calibration laboratory accredited by A2LA. It indicates traceability to standards provided by NIST (National Institute of Standards and Technology).  The stainless-steel probe has a diameter of 0.14 inches x 7-1/2 inch length and is resistant to most chemicals. The supplied silver-oxide battery runs continuously for one year. Large 3/4-inch digits are readable from 20 feet. Compact size is 2-1/2 x 4-3/4 x 1/2 inches, and weight is 2-3/4 ounces. Each product goes through an intense vetting process before carrying the Traceable name, which means you’ll save both time and money by not having to calibrate separately. The Traceable Kangaroo Thermometer applies to various unique applications such as the storage, laboratory, and medical industries. Specifications: Temperature Range F: -58 - 572F Temperature Range C: -50 - 300C Temperature Resolution: 0.1C Temperature Accuracy: +/-1C Programmable High and Low Alarm ISO 17025 Calibration Stainless Steel Probe Diameter of Probe: 0.14 in Length of Probe: 7.5 in Size: 2.5x4.75x.5 in Weight: 2.75 ounces

    $65.00

  • 4 Way Vacuum Manifold

    4 Way Vacuum Manifold

    4 Way Vacuum Manifold   The Vacuum Manifold can be used in conjunction with any vacuum application. It allows the user to selectively choose where to apply vacuum pressure. It is available in 1/4" or 3/8" barb connections and is assembled using 304-grade stainless steel parts. Please refer to the following example applications: Rotary evaporator vacuum distribution Multiple vacuum chambers with a single vacuum pump Air inlet to a vacuum system   ***Note: Vacuum Manifold is intended for use with vacuum pressure only. It is not rated for positive pressure.***

    $150.00

  • J-KEM Digital Temperature Monitor

    J-KEM Digital Temperature Monitor

    J-KEM Digital Temperature Monitor  Monitors and displays the temperature of an attached piece of equipment on a bright LED display. Built-in USB and free KEM-Net software provide remote temperature monitoring and data logging to a GLP/GMP compliant file. Audible alarm. Specifications: 120 or 230Vac, 50 watts.Warranty: 2 Years The temperature range desired determines the probe/thermocouple type: J [black] (0 – 800° C) K [yellow] (-50 – 1200° C) T [blue]  (-200 – 250° C)

    $576.00

  • J-KEM Model 250

    J-KEM Model 250

    J-KEM Model 250 The Model 250 has both heating and cooling outlets for maximum versatility. Two heating outlets supply 1800 watts of power for large equipment and heating mantles up to 22L. The third outlet (1800 watts), normally used for cooling, is programmable to supply power below, above, or at the set point. Contains J-KEM’s patented power control computer which provides 0.1° regulation of anything.   Specifications: 120vac, 15 amps, 1800 wattsWarranty: 2 Years The temperature range desired determines the probe/thermocouple type: J [black] (0 – 800° C)K [yellow] (-50 – 1200° C)T [blue]  (-200 – 250° C)RTD: (-200 – 400° C)

    $1,086.00 - $1,257.00

  • Water Circulation Vacuum Pump

    Water Circulation Vacuum Pump

    Water Circulation Vacuum Pump This Circulation and Vacuum Pump combines the best of both worlds by using the circulating water to pull a vacuum which requires no oil at all and has very low maintenance requirements overall due to this unique process and design. Each vacuum port on the unit pulls vacuum separately from one another so the user can use it for different applications at the same time or combined to increase the vacuum. This pump will also circulate water through the backports as needed to cool and application and dissipate heat as needed. Specifications Vacuum Degree 0.0980Mpa (735 Torr) @ 25°C Single Tap Exhaustion 10L/min Voltage 110V / 50Hz USA Plug Noise <50DB     Specifications Number of Vacuum ports: 2qty (independent vacuum po Vacuum Port Size: 3/8" Vacuum Depth: 16 torr Number or Water Circulation inlet: 1qty Number or Water Circulation Outlet: 1qty Pumping Speed: 6.5 L/min Reservoir Capacity: 12L Overall Dimensions: 15.5" x 11.5" x 17" Decibel: 62 dB Weight (no water): 17lbs 10oz

    $340.00

  • Digivac Vapor Pressure Controller

    Digivac Vapor Pressure Controller

    Digivac Vapor Pressure Controller The DigiVac Vapor Pressure Controller is a high-end lab-grade instrument that will allow you to determine set points and maintain vacuum at that specified level. The Vapor Pressure Controller is extremely useful when trying to maintain pressure at a certain level, for example, when trying to control the vacuum level as botanical oils are processed for use in the medical industry. Key Features: USB Communication Maintain Specific Vacuum Levels 3/8" Barbed Hose Connections Digital Readout Compact Design Lab Stand Bulkhead Specifications Sensor Type Sen-775i-NPT-OEM Accuracy +/- 2 Torr Units Torr, mbar Total Range 1 – 775 Torr The Vapor Pressure Controller is DigiVac’s newest product release. This instrument has the ability to help those working in the botanical market easily process plant material through automated distillations. It both measures and maintains the pressure within rotovaps, or any type of vacuum system, following the profile created on the Vapor Pressure Profile Manager - a free, downloadable software that comes with the purchase of a VPC. The front of the gauge is similar in terms of being straightforward. It has displays of both your current vacuum and chosen setpoint, as well as a numerical up/down control, regulation button, and power switch. Just hook your vacuum pump to one side, the rotovap to the other side and plug it in. If you’d like specific ramp rates and time duration, then install the free software, hook up the USB to connect the unit to the computer hosting the software and you can set up your process profile. The vacuum system is what you are going to regulate, an example being your rotovap, vessel, flask or vacuum oven. Once the unit is set up and regulating, the process can also be observed within the software, thus telling you how your system and pump are performing. Resources: DigiVac VPC Blog DigiVac Vapor Pressure Controller Data Sheet DigiVac Vapor Pressure Controller Quick Start Guide

    $1,880.00

  • J-KEM® Temperature Controller Model 210

    J-KEM® Temperature Controller Model 210

    J-KEM® Temperature Controller Model 210   J-KEM’s most compact, research-grade controller, yet packed with 1200 watts of power. Sufficient for heating mantles up to 5L in size and most laboratory ovens, hot plates, reaction blocks and other heaters. Contains J-KEM’s patented power control computer which provides 0.1° regulation of anything Specifications: 120vac, 10 amps, 1200 watts.Warranty: 2 Years The temperature range desired determines the probe/thermocouple type:   J [black] (0 – 800° C) K [yellow] (-50 – 1200° C) T [blue]  (-200 – 250° C) RTD: (-200 – 400° C)   Specifications: 120vac, 10 amps, 1200 watts Weight: 5 Lbs Dimensions: 7.4 x 5.2 x 3.25 in

    $949.00 - $1,130.00

  • J-KEM® Temperature Controller Model 260/Timer Complete

    J-KEM® Temperature Controller Model 260/Timer Complete

    J-KEM® Temperature Controller Model 260/Timer Complete   Designed for processes requiring an extra measure of safety. The Model 260/Timer disconnects outlet power if the process temperature exceeds the set point by a user-specified amount, or following recovery from a power failure. Power remains off until the controller is manually reset. Over temperature is signaled by both an indicator lamp and an audible alarm. Contains a 100-hour digital timer to turn heating OFF (or ON) when the time expires. The Model 260 has two power outlets (1800 watts) for large equipment or heating mantles up to 22L. Contains J-KEM’s patented power control computer which provides 0.1° regulation of anything.   SPECIFICATIONS: Power: 15 amps @ 120 VAC, 1800 Watts Weight: 6 Lbs Dimensions: 9.25 × 7.75 × 3.5 in .

    $1,295.00 - $1,465.00

  • J-Kem Gemini-2 Dual Temperature Controller

    J-Kem Gemini-2 Dual Temperature Controller

    J-Kem Gemini-2 Dual Temperature Controller  Gemini-2 Dual Temperature Controller displays two temperature controllers in a single cabinet to regulate two independent reactions. Each channel is 1200 Watts MAX (1800 Watts total), 15 Amps @ 120VAC, The Gemini is one of J-KEM’s most versatile controllers featuring high power outlets and a 100 hour digital timer (on channel 1) to turn heating OFF (or ON) at a user entered time. Features Included: Over-temperature protection circuits with audible alarms, dual temperature displays, selectable operating modes, double fused, and 100% solid state design. The USB port on the back panel of the controller is an interface to J-KEM’s KEM-Net software.  Safety features include: 100% solid state, double fused, audible error alarm, and over temperature circuitry that disconnects power if an over temperature condition occurs. Specifications: Dimensions: 3.5" H x 7.75" W x 8.75" D Power: 15 Amps @ 120VAC, 1200 Watts MAX/Channel, 1800 Watts (Total) Weight: 7 lbs Complete System Includes: One controller Two Teflon thermocouples (12″ long, 1/8″ diameter) Two connecting cords Two 14/20 joint adapters

    $1,569.00 - $1,921.00

  • J-KEM® Temperature Controller Model 270

    J-KEM® Temperature Controller Model 270

    J-KEM® Temperature Controller Model 270   The Temperature Controller Model 270 was design  for processes requiring uncompromising safety. The only temperature controller available with a built-in independent backup controller to guard against heating accidents from equipment failure. Features: The desired temperature is entered into the digital display of the setpoint controller which regulates heating. A high temperature limit is then entered into the second digital back-up. If the reaction reaches the setpoint of the second controller, power is shut off from the output circuit until the unit is manually reset. Both controllers independently monior the reaction temperature and in the event that one controller fails, the other takes over to prevent a accident. The USB port on the back panel of the controller is an interface to J-KEM’s KEM-Net software.   Specifications: Dimensions: 9.25 × 7.75 × 3.4 in Power: 15 Amps @ 120VAC, 1800 Watts Weight: 7 lbs

    $1,728.00 - $1,893.00

  • Stainless Steel Tri-Clamp x Female Joint Adapter

    Stainless Steel Tri-Clamp x Female Joint Adapter

    This unique adapter allows the user to adapt a Tri-Clamp fitting to a male ground joint glass fitting and it is made out of 304 stainless steel.

    $30.00 - $35.00

  • GL-14 Cap

    GL-14 Cap

    GL-14 Cap This GL-14 cap is used for sealing off GL-14 connections or venting vacuum in a system without the use of a valve. Gasket not included. (Note: Only 1 cap included. Increase quantity to order more caps.)

    $5.00

  • Chemglass PTFE Thermocouple Adapters

    Chemglass PTFE Thermocouple Adapters

    PTFE Thermocouple Adapters CG-1048-A Chemglass PTFE adapters are for use with either 1/8” or 1/4” thermocouples. The adapter has an outer Viton® o-ring to form a grease-free, airtight seal between the adapter and the listed size of the outer joint. The compression nut works in conjunction with the upper Viton® to provide an airtight seal between the adapter and thermocouple. Adapter design permits use with CG-145 Keck clips.

    $55.00

  • KF High Vacuum Stainless Steel Flange x Female Joint Adapter

    KF High Vacuum Stainless Steel Flange x Female Joint Adapter

    This unique adapter allows the user to adapt a KF25 or KF40 High Vacuum Flange fitting to a male ground joint glass fitting and it is made out of 304 stainless steel.

  • J-Kem The Quad

    J-Kem The Quad

    J-Kem The Quad  Because we’ve never met a chemist with too much bench space! The Quad packs four independent temperature controllers into a single, compact unit. Each of the four controller channels has 1200 watts of power, an independent display, and an over-temperature protection circuit. Contains J-KEM’s patented power control computer which provides 0.1° regulation of anything. Specifications: 120vac, 15 amps, 1800 watts total, 1200 watts maximum per channel.Warranty: 2 Years   The temperature range desired determines the probe/thermocouple type: J [black] (0 – 800° C)K [yellow] (-50 – 1200° C)T [blue]  (-200 – 250° C)RTD: (-200 – 400° C)   PURCHASE WITH OR WITHOUT SYSTEM ACCESSORIES Complete system includes: one controller, four Teflon thermocouples (12″ long, 1/8″ diameter), four connecting cords, and four 14/20 joint adapters.

    $2,897.00 - $3,539.00

  • J-KEM DVM-100

    J-KEM DVM-100

    J-kem DVM-100  The DVM-100 continuously displays the pressure in a connected piece of equipment on a large digital display. The vapor path of the DVM-100 is 100% stainles steel to provide long life and chemical compatibility. Comes with J-KEM’s KEM-Net software to provide data logging and a real time graphical display of system pressure. The DVM-100 provides vacuum monitoring but not vacuum regulation.  

    $1,162.00 - $1,173.00

  • J-KEM Model 150

    J-KEM Model 150

    J-KEM Model 150  An ideal controller for applications that don’t require the precise regulation of J-KEM’s 200-Series controllers. This compact unit packs 1200 watts of power, sufficient for 5 L heating mantles, many ovens, and other devices. Built with J-KEM’s state-of-the-art PID process controller, but does not contain J-KEM’s power control computer. Specifications: 120vac, 10 amps, 1200 wattsWarranty: 2 Years The temperature range desired determines the probe/thermocouple type:   J [black] (0 – 800° C) K [yellow] (-50 – 1200° C) T [blue]  (-200 – 250° C)   Weight: 4 Dimensions: 5.4 x 3.75 x 2.5 in PURCHASE WITH OR WITHOUT SYSTEM ACCESSORIES Complete system includes: one controller, one Teflon thermocouple (12″ long, 1/8″ diameter), one connecting cord, and one 14/20 joint adapter.

    $608.17 - $764.00

  • BVV PTFE Thermocouple Adapters

    BVV PTFE Thermocouple Adapters

    BVV PTFE Thermocouple Adapters BVV PTFE adapters are for use with either 1/8” or 1/4” thermocouples on 24/40 ground glass joints. The adapter has an outer Viton O-ring to form a grease-free, airtight seal between the adapter and the listed size of the outer joint. The compression nut works in conjunction with the upper Viton® to provide an airtight seal between the adapter and thermocouple. (Compare to Chemglass CG-1048-A Thermocouple Adapters.)  

  • DigiVac SNAP Vacuum Controller | Simple, Nimble, Automatic Process Control | Up to 8 Recipes

    DigiVac SNAP Vacuum Controller | Simple, Nimble, Automatic Process Control | Up to 8 Recipes

      DigiVac SNAP Vacuum Controller | Simple, Nimble, Automatic Process Control | Up to 8 Recipes   Description SNAP Vacuum Controller | Simple, Nimble, Automatic Process Controller with up to 8 Recipes SNAP: Automatic Vacuum Process Controller | Vacuum control and venting with the touch of a button or twist of a dial Vent your vacuum chamber or equalize your system with the touch of a button instead of pulling hoses or turning valves Treat material in chamber more gently by implementing kinder ramp rate controls which is ideal for freeze drying, vacuum drying or lyophilization applications Vacuum Controller with onboard ramp rate recipe control. Set up to 8 recipes based on time and pressure setpoints. Dashboard pushbutton control for START, STOP functionality for each channel allows you to automatically vent or isolate your system with a push of a button Ideal for automating and simplifying vacuum chamber pressure control. SIMPLE – SIMPLIFY YOUR LAB & CONTROL MORE WITH LESS Applications: vacuum chamber (from 1 liter to 1000 liters) research, vacuum ovens/vacuum drying, vacuum furnaces, large scale food processing, microwave drying, composites, rotary evaporators, falling film systems Fine control of target vacuum pressure for more precise processing and research Enables using reliable and long lasting rotary vane pumps & dry scroll pumps in applications where diaphragmpumps were previously required Keeps vacuum pumps near their base pressure resulting in greater longevity NIMBLE – MAXIMIZES THROUGHPUT & PUMPDOWN SPEED Largest flow paths available to insure maximum flow for faster evaporation Maximize throughput and pump down speed with a 20 mm vacuum path (almost full KF25 orifice) AUTOMATIC PROCESS – PRECISION CONTROL & INTUITIVE DESIGN Automatic Vacuum Process Controller | precise automated control with programmable recipes and graphing of vacuum levels Innovative valve control performs both proportional throttle and bleed vacuum control (vent to atmosphere) The integrated bleed design allows you to quickly vent to atmosphere to stop bumping during processing Numerical readings right on the LCD screen and one touch buttons: VENT, CLOSE (isolate, close all valves) and FULL VAC (fully opens the valve for vacuum pump and closes the vent valve) SNAP Vacuum Controller Wetted Material Options Aluminum (6061) wetted surfaces Stainless steel (304) wetted surfaces Measurement and Control Range: 1 Torr to 775 Torr (standard) Need millitorr range?: SNAP has a RJ45 Port for adding an additional sensor to extend the measurement range. We recommend the addition of the DCP Quantum to be able to monitor and control from 0.01 Torr to 1000 Torr.   DigiVac SNAP Data Sheet  DigiVac SNAP Operational Manual  DigiVac SNAP Quick Start Guide 

    $4,650.00

  • Vacuubrand VARIO® chemistry pumping unit PC 3001 VARIOpro

    Vacuubrand VARIO® chemistry pumping unit PC 3001 VARIOpro

    Vacuubrand VARIO® chemistry pumping unit PC 3001 VARIOpro   The PC 3001 VARIO select pumping unit precisely controls the vacuum level in order to achieve unparalleled process control. This pump is suitable for even high boiling point solvents. The integrated VACUU·SELECT controller provides an easy-to-use, application based interface that covers all common lab applications. The VACUU·SELECT controller has you covered. Use manual set-point-control for simple processes, run fully automated distillations, or create your own application with simple drag-and-drop editing. For solvent evaporation, the VACUU·SELECT controller detects solvent boiling and automatically adjusts the pump's motor speed to maintain process control. The VARIO motor speed control also makes the pump whisper quiet and provides for exceptionally long maintenance intervals. The inlet separator, made of glass with a robust protective coating, prevents particles and liquid droplets from entering the pump, preventing damage and extending pump life. And the exhaust vapor condenser allows for nearly complete recovery of solvents when used with a chilled water line or recirculating chiller for economical recycling and environmental protection.   Performance features simplify lab work with the VACUU·SELECT vacuum controller with graphic user interface and predefined applications automatic boiling point detection and continuous optimization of vacuum levels for quick process times compact and powerful; superior performance even with continuous condensate purge whisper quiet and ultra low vibration eco-friendly: extremely low power consumption and efficient solvent recovery. Oil-free!     CE Approval  Safety Information Manual Controller Manual  Manual interfaces       Technical data Unit PC 3001 VARIO select Vacuum controller VACUU·SELECT Number of heads / stages 4 / 3 Max. pumping speed m3/h 2.0 Max. pumping speed cfm 1.2 Ultimate vacuum (abs.) mbar/torr 2.0 / 1.5 Ultim. vac. (abs.) with gas ballast mbar/torr 4 / 3 Ambient temperature range (operation) °C 10 - 40 Ambient temperature range (storage) °C -10 - 60 Max. back pressure (abs.) bar 1.1 Inlet connection Hose nozzle DN 6-10 mm Outlet connection Hose nozzle DN 8-10 mm Coolant connection 2 x hose nozzle DN 6-8 mm Rated motor power kW 0.16 Motor speed range min-1 200 - 3000 Protection class IP 20 Dimensions (L x W x H) mm 303 x 306 x 400 Weight kg 8.2 Noise level at 50 Hz, typ. dBA 42 ATEX conformity (only 230V) II 3/- G IIC T3 X Internal Atm. only Items supplied Pumping unit completely mounted, ready for use, with manual. Accessories Rubber vacuum tubing DN 6 mm (20686000) Rubber vacuum tubing DN 8 mm (20686001) Coolant valve VKW-B (20674220) Vent valve VB M-B (20674217) Liquid level sensor (20699908) VACUU·BUS® Y-Adapter mit Kabel 2m (20683240)

    $9,700.00

  • GL-18 Cap with Aperture, High Temperature

    GL-18 Cap with Aperture, High Temperature

    GL-18 Cap with Aperture, High Temperature   Open top cap for use with GL screw threads. The cap combined with the CG-197 sealing ring will accommodate tubing of the listed diameter. Cap is made from PPS (polyphenylsiloxan) and will withstand temperatures up to 250°C.

  • Chemglass #45 Rodaviss Joint Cap w/ Hole

    Chemglass #45 Rodaviss Joint Cap w/ Hole

    Chemglass #45 Rodaviss Joint Cap w/ Hole   Threaded cap fits CG-172 outer joint, Rodaviss®. When used with CG-305 Viton o-rings, provides for greaseless high vacuum seal.

    $18.00

  • Glas-Col Thermocouple Type "J" Mini Plug

    Glas-Col Thermocouple Type "J" Mini Plug

    Glas-Col Thermocouple Type "J" Mini Plug   D x L :  1/4" x 4" Lead Length: 72"

    $70.00

  • Glas-Col Vapor Monitor

    Glas-Col Vapor Monitor

    Glas-Col Vapor Monitor   motor vapor temperature or other processes  audible alarm - high, low, t/c break  digital display      Specifications TC Type "J" MUST BE ORDERED SEPARATELY Range 0 - 999 C Dimensions 4" W x 4" D x 4" H Volts 120 Includes: 6' attached power cord and grid support bracket

    $280.00

  • J-KEM DVR-200-EV Digital Vacuum Regulator

    J-KEM DVR-200-EV Digital Vacuum Regulator

    J-KEM DVR-200-EV Digital Vacuum Regulator The DVR-200-EV has the same stainless steel pressure transducer inside, but the vacuum valve is outside of the controller. The value of this design is that the vacuum valve can be cleaned or replaced much easier than the valve in the classic DVR-200. Some applications, like distillations or stripping large volumes of solvent, can leave residues inside the valve which causes it to fail. Replacing the vacuum valve is the most frequent repair that J-KEM performs on the DVR-200. Replacing the valve in the classic DVR-200 is difficult and must be returned to J-KEM for repair. With the EV version, the user can disassembled the valve and wash it out, or even replace it in under 5 minutes. For large distillations or botanical applications, J-KEM recommends the DVR-200-EV. No Mercury 100% digital pressure entry and control Wetted parts are 100% stainless steel and Teflon Vacuum ramping feature eliminates bumping Resists: All organic solvents Acids Bases Water   Specifications: 100 watts. Vacuum fittings: 1/8″ NPTM. Warranty: Electronics 2 Years, Vacuum Valve 6 months (void if damaged by chemical buildup)

    $1,638.00

  • FYRA for End of Primary Drying Detection | Vacuum Drying Monitoring | for Lyophilization| CE, UL, CSA

    FYRA for End of Primary Drying Detection | Vacuum Drying Monitoring | for Lyophilization| CE, UL, CSA

    FYRA for End of Primary Drying Detection.  This bundle is set up to allow for vacuum drying applications like freeze-drying and vacuum ovens to help determine the end of drying. Will help you detect when most of the water or residual solvent from a product has been removed or the end of primary drying has been reached in a vacuum drying application. Background on How this FYRA End of Primary Drying package works: When a freeze dryer is equipped with both a thermal and direct measurement, these sensors can be utilized to indicate the end of primary drying (Source). Step One: Clean process documentation | Get a baseline Characterize the convection-enhanced Pirani and the capacitance manometer (in this case the DCP Quantum) against each other in a dry, empty and refrigerated system. The freeze dryer is turned on, as per the manufacturer’s operator manual, with nothing on the shelf. The shelf temperature can be left at room temperature, and if so the cold trap, the condenser, and the vacuum pump should be on and running for a period of time The vacuum oven or freeze dryer is allowed a period of time to become stable in this condition and the Pirani and capacitance manometers are read. The difference in their pressure readings in a dry, empty and refrigerated freeze dryer will be relatively small (mT to 10’s of mT) when the system is working properly. DigiVac will NOT calibrate these two gauges against each other. There may always be slight differences in their readings due to their difference in design. The difference in pressure (ΔP) between these two gauges, when dry, empty, and refrigerated, indicates how close they come together when there is little to no water vapor in the gas mix over the product. Step 2: Drying with Product The intent of primary drying is to maximize the sublimation rate within the product. As such the gases in the chamber have a high water vapor content. The Pirani sensor will read a higher pressure than the capacitance manometer. As freeze drying progresses the amount of ice converting to vapor through the sublimation process will decrease as the product becomes lyophilized from the top through the bottom of the product. Eventually, the Pirani and capacitance manometers will approach the ΔP that was established in a dry, empty and refrigerated system. Approaching this ΔP value indicates that the end of primary drying has occurred. The DigiVac FYRA controller has a rich remote command-line interface which enables the user a high degree of remote control and monitoring from any computer when communicating through the USB port. Calibrated—Every FYRA is calibrated and pretested under actual vacuum against a NIST standard (Need NIST traceable documentation? Add this option to your order) Applications—Ideal for End of Drying Detection, Freeze Drying Primary Drying Monitoring, and Vacuum Oven Drying Monitoring and Detection DCP Quantum DuoSense Measurement Range: .05 mT to 1000 Torr 275 Convection-enhanced Pirani Measurement Range: 0.1mT to 1000 Torr FYRA Bleed Vacuum Controller Components: FYRA controller Convection-enhance Pirani KF25  gauge sensor | Lesker 275, driver card, and Pirani sensor cable Quantum DCP Gauge and driver card | DuoSENS Capacitive Piezo Vacuum Sensor 0.01 to 1000 Torr, Gas Independent 3 Simple Steps for Vacuum Process Set-up with FYRA Vacuum Controller: Plumb the vacuum gauge(s) and valve into your vessel Connect the sensor, power, and I/O cables into FRYA Measure and control vacuum

    $3,456.00

  • Wireless Digital Vacuum Gauge 1~19,000 Microns

    Wireless Digital Vacuum Gauge 1~19,000 Microns

      VGW-mini Wireless micron vacuum gauge measures vacuum via just one service port and with no loss of refrigerant. Its compact, robust and smart design support HVAC technicians with numerous intelligent features like the graphic display of measurement data in the Elitech Tools App. Its smart Bluetooth integration allows for data to be stored and evaluated reliably and efficiently, thus saving precious time and resources. Product Features High Accuracy The digital vacuum gauge achieves precise deep vacuum measurements down to single digit resolutions and provides notifications when the evacuation target is met. Smart APP Control Control your micron tester remotely and navigate through all measurement data via Smartphone or Tablet. Quickly and conveniently document your job, finalize your report and export - directly from the job site. Intelligent Judgement of H2O Status The vacuum meter automatically judges physical state of H2O by comparing ambient temperature and water saturation temperature corresponding to the vacuum in the system. Large, Easy-to-Read Display Continual digital readout of evacuation process can be viewed easily on the large, full-view LCD screen. Rechargeable Lithium Battery Built-in rechargeable lithium battery can work up to 20 hours per single full charge, saving troubles of frequent battery change.     Product Specifications Measuring Range: 0-19000 micron Operating Temperature: -4℉~140℉ (-20°C~60°C) Interface: 1/4 SAE Accuracy: 1~10,000 microns: ±10% of readings ±10 microns10,000~19,000 microns: ±20% of readings Resolution: 0-400 1 Micron400-3000 10 Micron3000-10000 100 Micron10000-19000 250 Micron Vacuum Units microns, mTorr, in/hg, Pa, Torr, KPa, mbar and psia Battery rechargeable lithium battery (1,000mAh) Overload 27.5 bar Certification CE

    $170.00

  • Solid Cap, PTFE Seal, GL-14 Thread

    Solid Cap, PTFE Seal, GL-14 Thread

    Cap is made from PBT (thermoplastic polyester) and will withstand temperatures from -45 to 200º C. The seal is PTFE

    $6.00

Login

Forgot your password?

Don't have an account yet?
Create account