New Products

1746 products


  • CVO-10 PRO Vacuum Package

    CVO-10 PRO Vacuum Package

    CVO-10 PRO Vacuum Package  (With MAXTRAP105) A complete vacuum drying system designed for temperature sensitive, high-thru-put for vacuum purging large production quantities.  Cascade’s MAXTRAP105 is a -105°C cold trap integrated in the system to keep the Agilent IDP15 vacuum pump operating with minimum downtime and maximum efficiency.   Cascade’s Model CVO-10 offers incredible temperature stability for vacuum drying and purging of pharmaceuticals, botanicals, slurries, isolates – especially temperature sensitive material. This vacuum oven will liberate solvents, pentane, water or other unwanted compounds in large batch production environments. The cold trap MAXTRAP105 (-105°C) will keep the vacuum pump running optimal and allow for capture of outgassed material in the steel trap. The entire system is set on an industrial mobile cart for easy mobility and to help keep the lab clean. NRTL Certified.  Cascade Vacuum Ovens and cold trap are Made in USA.   CVO-10 PRO Package with MAXTRAP105 Includes Cascade Sciences CVO-10 Vacuum Oven Heavy-Duty Industrial Mobile Carts for oven, vacuum pump and cold trap 9 Shelves, Aluminum, full extension, slide and stay in place Copper shelf bracket insert facilitates fast, stable heat transfer to shelves under vacuum MAXEVAP Connection Kit MAXTRAP105 Vacuum Cold Trap (-105°C) Agilent IDP15 Oil-Free Vacuum Pump, 9cfm All connections, hoses CVO-10 Vacuum Oven Features: Temperature Range:  Ambient +26°F to 302°F / Ambient +14.4°F to 150°C Temperature Uniformity:@ 105°F  +/- 2°F@ 200°F +/-5.5°F@ 300°F +/- 8°F NRTL Certified by TUV Stable temperature control. Touchscreen temperature readout with temp sensor INSIDE the oven VITON door gasket Bright LED lights in window for visibility of sensitive material Digital vacuum gauge reads in inches of mercury or torr Smooth, quarter-turn vent valve Rear KF-25 port includes MAXEVAP Connection Kit for rapid vacuum drying or running feedthroughs inside oven for monitoring 220V / 1ph  / 10AMPS  NEMA 6-15R Plug Quality Tempered Rated Glass NGI-US to ANSI Z97.1.2007 156CFR/201 11  SGCC -2577 ½ UA Fast venting with larger ½” diameter vent line also allows for nitrogen or other inert gas connection Touch Panel LED control screen with user settable features, easy updates Mobile cart on heavy duty casters   Agilent IDP15 Oil-Free Scroll Vacuum Pump Features: 9 CFM pumping speed Quiet.  Less noisy that diaphragm or oil-rotary vane pumps Oil-Free. Eliminates contamination risk. No Inlet / Exhaust Filters Required Hour meter tracks service intervals 1 Year Warranty NRTL Certified Maintenance is the replacement of a single interior tip seal. Order our IDP15 Tip Seal Replacement Kit or ask us about our maintenance service. Pull Deeper Vacuum / Better Vapor Tolerance With Gas Ballast Positions. The IDP15 has two gas ballast ports that assist the pump in handling condensing gases such as water vapor, or other gaseous products that become liquids or solvents when reaching atmospheric pressure.   MAXTRAP105 105°C Cold Trap Inlcudes: Cascade’s COLDWELL 304 Stainless Steel Trap – patent pending baffle system. 3 Quart Capacity (2839ml) Viton Gasket Labconco -105°C Refrigerated Base Green CFC / HFC Free Refrigerants KF-25 Inlet/Outlet, Connection Line & Hardware Power Cord 3mm Neoprene Insulator Cap Requires ~800ml (~ 3.5 cups) of a transfer fluid such as ethanol. Not Included. Cascade recommends: ethanol, glycol, cryo-cool fluids Quality Made in USA NRTL Certified

    $38,642.00

  • Neutral Activated Alumina Chromatographic Grade (50-200um) *Compare to Alumicel™N

    Neutral Activated Alumina Chromatographic Grade (50-200um) *Compare to Alumicel™N

    Neutral Activated Alumina pH: 6.8 | 50-200 Micron Made in USA *Compare to Alumicel™ N This activated alumina is a neutral pH adsorbent used to remove excess moisture from your extraction and CRC process.  The addition of this media is used as the last layer in the typical BVV™ CRC setups.  This grabs any excess moisture from the previous CRC layers and the Biomass.  The activated alumina will produce a sugary finish almost immediately after you start your purge.  This rapid crystallization is because the process has stripped out additional phospholipoids and fats. This produces an overall extract that is less prone to oxidation and has a longer shelf life.  Chromatographic Grade Manufactured in the USA since 1937 Manufactured to the highest quality standards ISO 9001:2015 BVV™ Neutral Activated Alumina Technical Data Sheet BVV™ Neutral Activated Alumina Safety Data Sheet BVV™ Neutral Activated Alumina Quality Certificate

    $54.00 - $9,500.00

  • Sale -6% Welch BTpro100

    Welch BTpro100

    Welch BTpro100 Welch’s BTpro vacuum pump series has a flow and vacuum level to provide fast performance for your size of rotary evaporator, glass reactor, purge oven, or winterization filtration apparatus.These chemical duty PTFE diaphragm pumps are oil-free. The pumping action and deep vacuum comes from the movement of PTFE diaphragms within PTFE heads. All wetted services in the flow path are made of fluoroplastic making the BTpro pump highly chemically resistant. As a result, the BTpro vacuum pump series is near-zero maintenance. A cold trap placed in-line with BTpro pump is needed if terpenes are part of the flow path.   Model BTpro100 Free Air Displacement@60Hz,lpm(CFM) 100(3.5) Ultimate Vacuum Pressure, Torr 6 Maximum Vacuum, in. Hg 29.7 Horsepower, HP (watts) 0.5(390) Built-in adjustable vacuum - Gas Ballast Yes Head Material PTFE Diaphragm PTFE Inlet/outlet Connection NW16 flange1 Agency (National Recognized Lab) cUL Weight, lbs (kg) 40.3(18.3) Overall DimensionsLxWxH in.(cm) 9x15x7(23x38x18) Shipping Weight, lbs(kg) 48.5 (22) Shipping Carton DimensionsLxWxH in.(cm) 18.9x12.6x11.8(48x32x30)

    $4,850.00$4,575.00

  • 1LB EVO Closed Loop Extraction Kit

    1LB EVO Closed Loop Extraction Kit

    1LB Evo Closed Loop Extraction Kit (System comes with 1 yr. limited warranty) The EVO series of 1LB closed-loop extractors was designed with the evolution of stand-up extractors in mind. The aim of the EVO series of extractors is to provide unparalleled utility and ease of use within a traditional stand-up design.  The EVO series was designed to tackle the two most common plights with stand-up extractors, difficulty in extract harvesting, and integration of adsorbent filtration. The Evo series accomplishes both through the use of its elevated extract pour spout and its optional inline color remediation column. Beyond the elevated pour spout and optional inline color remediation column. The EVO series aims to provide unbridled safety and solvent recovery speed through the integration of ASME pressure relief valves on both the material column and collection base standard and full bore 1/2" recovery lines found on the professional, elite, and active explorer models. The 1lb EVO Closed Loop Extraction kit comes complete with a top fill injection manifold including a compound gauge, a 125 psi ASME pressure relief valve, and two full bore ball valves complete with 2x 1/4" Male JIC connections on the explorer and both 1/4" & 1/2" Male JIC connections on the professional and elite models. Just below the injection manifold, all 1lb EVO models have a solvent dispersion plate that evenly disperses solvent into the 3"x 24" 1lb material column which is enclosed by 2x 100 micron Buna-N mesh gaskets.  Both the Professional and Elite models come complete with an inline 3" x 6" color remediation column just below the material column with a 300-gram media capacity and a filter stack utilizing both a 5 micron & 1 micron sintered disk. Professional and Elite models also include 25-micron filter paper and a 500-gram sample of Pure-Flo B80   Below the 1lb material column and optional inline color remediation column the 1lb Evo includes the jacketed and elevated pour spout collection base that allows for easy extract harvesting and speedy solvent recovery.  The elevated base can accommodate up to a 5:1 solvent to biomass ratio and accept a standard round pyrex dish or a small parchment paper boat below the pour spout.  Upon completion of the run, extract removal is made easy by simply draining the extract from the elevated extract pour spout. Both the professional, elite, and active explorer models have increased solvent recovery capability from the jacketed collection base through full bore 1/2" recovery MJIC connections and stainless steel recover hoses.  Beyond the larger recovery lines and inline color remediation column the 1lb EVO Elite options come paired with our ETL listed 5 liters Neocision heated circulator and the sleeved EVO recovery tank that allows for the pre-chilling of solvent and speedy solvent recovery, reaching sub 20 minute recovery times on high heat. All varients of the EVO Extraction Kits come equipped with a 1.9CFT vacuum oven, a 7CFM single-stage vacuum pump, a 5' HVAC hose, and an 8"x8" silicone pad. The Explorer & Professional models come with the ECO model vacuum ovens and the Elite versions equipped with the ETL list Neocision 1.9CFT vacuum oven.  All EVO closed-loop extraction kits come available with an active recovery option including: BVV 2 Cylinder Butane Recovery Pump ITS/ETL to ANSI/ISA Certified BVV Large Condensing Coil 1/2" x 24" SS JIC Braided Hose (2) 1/2" x 48" SS JIC Braided Hose (2) 1/2" x 60" SS JIC Braided Hose Molecular Sieve Filter Drier BVV 5' HVAC Hose BVV  Vacuum Tee ***Note: Solvent not included with systems unless ordered separately. Any order with butane WILL NOT SHIP EXPEDITED.*** ***DISCLAIMER: This unit is intended for LEGAL purposes only, to be used in accordance with local laws and ordinances. Use only in extremely well-ventilated areas. Check with your local fire marshal for guidance when operating indoors. KEY BENEFITS Meets or exceeds all industry listed standards Versatile in running butane, propane, and other blended solvents Perfect for mid to large-scale extraction/production facilities  Faster run times and less degradation in the process Easy extract harvesting using the elevated pour spout Inline color remediation Extractor Configuration: Explorer: Our standard, most economical setup, perfect for the entry-level extractor on a budget. Comes with the jacketed and elevated collection base and 1/4" Male JIC connections on the injection manifold and collection base. The explorer options include a 1.9CFT ECO Vacuum Oven, a 5' HVAC hose, and a 7CFM single-stage vacuum pump. This model does not include the inline color remediation column or 1/2" Male JIC recovery/ injection connections. The Explorer model is forward compatible and can be easily upgraded to include 1/2" lines and the inline color remediation column. *This model does not come with a heated circulator* Professional: This model includes all the features of the explore model with the increased functionality of an inline color remediation column Just under the material column that comes with 25micron filter paper and a 500-gram sample of b80, an upgraded stainless steel recovery tank, and a full bore 1/2" Male JIC connection included on the injection manifold and collection base.  The Professional extraction kit options include a 1.9CFT ECO Vacuum Oven, a 5' HVAC hose, and a 7CFM single-stage vacuum pump.*This model does not come with a heated circulator* Elite: The Elite series is the premium version of the Professional. It features the same 1/2" Male JIC, and inline color remediation column upgrades. But also includes the EVO recovery tank and 5 liter ETL listed Neocision heated circulator that allows for pre-chilling and speedy recovery of solvent.  The Elite options include a 1.9CFT ETL Listed Neocision Vacuum Oven, a 5' HVAC hose, and a 7CFM single-stage vacuum pump. Passive: Passive recovery is the standard option on the extraction kit with the explorer model coming with 1/4" recovery lines and the professional and elite models coming equipped with 1/2" recovery lines. Active: The Active Recovery Upgrade Kit will increase recovery times by condensing the vapor a lot faster than just a hot/cold differential. All active models come equipped with 1/2" recovery lines and the inclusion of our BVV 2 Cylinder Butane recovery pump, BVV Large Condensing Coil, Molecular Sieve Filter Drier, and all the associated hosing to perform active recovery.   Explorer Professional Elite Jacketed & Elevated pour spout collection base Jacketed & Elevated pour spout collection base Inline Color remediation column 25-micron filter paper 500 gram B80 sample 1/2" recovery lines 30# Stainless steel Recovery Tank Jacketed & Elevated pour spout collection base Inline Color remediation column 25-micron filter paper 500 gram B80 sample 1/2" recovery & Injection lines EVO Recovery Tank 5 liter ETL listed Neocision heated circulator with insulated hoses     Unit Includes: Full bore injection Manifold complete with a compound gauge,125 PSI ASME pressure relief valve, and 2x 1/4" MJIC connections (1x1/2" MJIC connection on professional & elite models) 3"x24" 1lb Material column with solvent dispersal plate. 3"x6" Color remediation column 300g gram media capacity complete with a filter stack including 5 micron and 1 micron sintered disks (Professional & Elite model) 25-micron ashless filter paper (Professional & Elite) Jacketed & elevated collection base with extract pour spout 6" hemispherical collection base lid complete with borosilicate sight glasses, a compound gauge, 125 PSI ASME pressure relief valve, and full bore ball valves with MJIC Connections. 30# LP storage and recovery tank (Explorer) 30# stainless steel LP tank (Professional) & EVO Recovery tank (Elite) (1) 1/4" 72" FJIC Stainless Steel Injection hose (Explorer & Professional) 1/2" 96" FJIC Stainless Steel Injection Hose (Elite) (1) 1/4" 60" FJIC Stainless Steel Recovery Hose (Explorer) 1/2" 60" FJIC Stainless Steel Recovery Hose (Professional & Elite) High-pressure clamps Specifications: 3"x 24" 304 Stainless Steel Material Column-1lb capacity (450g) 316 Stainless Steel Fully Encapsulated Miniature Ball Valves System Rated to 150PSI Multiple 37 degree FJIC port connections 304 Stainless jacketed & elevated collection base Tri-Clamps at all interfaces make for a high pressure/standard pressure, easy-clean unit BUNA-N Gaskets are designed for Oil Processing Temp range -40-200F, and have superior solvent resistance Construction: All components are made of 304 Stainless Steel. Max Vacuum -29.9inHg High Polish Interior   *Note: Column capacity may vary depending on the density of packed material and packing density. Capacity is calculated using the industry standard of 4.2g/in3. This is the upper limit for column capacity. Low density, uncut, and/or lightly packed material can reduce capacity by 50%. For best results, we recommend to tightly pack coarse ground material.

    $4,275.00 - $10,979.00

  • BVV Recovery Pump Top Dead Center Piston Calibration Plate

    BVV Recovery Pump Top Dead Center Piston Calibration Plate

    BVV Butane Recovery Pumps Top Dead Center Calibration Plate & Bolts Use with the Top Dead Center Clearance (TDCC) instructions Use this plate and a depth gauge to measure the Top Dead Center Clearance of the piston/cylinder/head assembly.  Shims that come with the piston cylinders are stacked to create an area of displacement between the top of the cylinder and the compressor head. BVV's Recommended depth is 0.012" for the BVV 4 & 2 Cylinder Butane Recovery pumps. This gap is recommended for optimum recovery performance.  Top Dead Center Clearance Instructions *Depth Gauge Not included, Any simple depth gauge will work, and you will also need the shims that come in the BVV-6 kit. 

    $28.00

  • CPS TRS21 Top Dead Center Piston Depth Calibration Plate

    CPS TRS21 Top Dead Center Piston Depth Calibration Plate

    CPS TRS21 Top Dead Center Calibration Plate & Bolts Use with the Top Dead Center Clearance (TDCC) instructions Use this plate and a depth gauge to measure the Top Dead Center Clearance of the piston/cylinder/head assembly.  Shims that come with the piston cylinders are stacked to create an area of displacement between the top of the cylinder and the compressor head. BVV's Recommended depth is between 0.008" and 0.012" for the CPS TRS21 for optimum performance.  Top Dead Center Clearance Instructions *Depth Gauge Not included, its only used for reference in the photo. Any type of simple digital depth gauge will work to check the piston displacement. 

    $20.00

  • Upgraded TRS21 Compressor Head Complete, Stainless Fittings, Viton

    Upgraded TRS21 Compressor Head

    Upgraded TRS21 Compressor Head Complete, Stainless Fittings, Viton   Upgrade your TRS21 by purchasing a new Compressor Head with Viton O-rings for butane and propane gas compatibly and stainless steel fittings to meet FDA guidelines on handling of consumable products.  This head is assembled here in the USA and is a direct replacement for any TRS21 Compressor Head. 

    $180.00

  • TRS21 & BVV Butane Recovery Pump Valve Rebuild Kit

    TRS21 & BVV Butane Recovery Pump Valve Rebuild Kit

    This is the complete valve rebuild kit for the cylinder head on the BVV Recovery pumps or the TRS21.  This is only for 2 pistons.  So if you have the BVV 4 Cylinder pump you would need two kits.  These gaskets are upgraded and are compatible with butane and propane gasses, all the O-ring seals in this kit are Viton

    $80.00

  • CPS TRS21 Compressor Head Complete Stainless Rebuild Kit

    CPS TRS21 Compressor Head Complete Stainless Rebuild Kit

    CPS TRS21 Compressor Head Rebuild Stainless Kit Upgrade the compressor head on the TRS21 to be compatible with CBD oils by replacing all the existing O-ring seals with Viton.  Replace all brass fittings with Stainless Steel to by inline with FDA on consumable products.  Replace springs and valves. Compressor Head Rebuild Instructions

    $80.00

  • TRS21 Valve Head Complete Viton O-ring Kit

    TRS21 Valve Head Complete Viton O-ring Kit

    Replacement kit with Viton O-rings for the TRS21 head. Compatible for use with the Oil Extraction Market, Butane and Propane Extraction solvents. 

    $25.00

  • BVV 5.75" Glass Chamber Lid

    5.75" Glass Chamber Lid

    BVV 5.75" Glass Chamber Lid This tempered soda lime glass lid is available with or without holes. Both feature 5.75" outer diameter and a thickness off 12mm or .472". 

    $32.00 - $52.00

  • Huber adapter M16x1f-1/2"m

    Huber adapter M16x1f-1/2"m

    Huber adapter M16x1f-1/2"m Adapter M16x1 f - R1/2 m Adapter M16x1 f - R1/2 m M16x1 female thread to R1/2 male thread

    $135.00

  • Packing Rod Extension Screws

    Packing Rod Extension Screws

    Packing Rod Extension Screw   This packing rod extension screw allows you to combine our 24" Packing Rod Extension to our standard Stainless Steel Packing Rods making it easier to pack material columns greater than 36" in length.

    $2.00

  • Sale -9% DigiVac SNAP Vacuum Controller | Simple, Nimble, Automatic Process Control | Up to 8 Recipes

    DigiVac SNAP Vacuum Controller | Simple, Nimble, Automatic Process Control | Up to 8 Recipes

      DigiVac SNAP Vacuum Controller | Simple, Nimble, Automatic Process Control | Up to 8 Recipes   Description SNAP Vacuum Controller | Simple, Nimble, Automatic Process Controller with up to 8 Recipes SNAP: Automatic Vacuum Process Controller | Vacuum control and venting with the touch of a button or twist of a dial Vent your vacuum chamber or equalize your system with the touch of a button instead of pulling hoses or turning valves Treat material in chamber more gently by implementing kinder ramp rate controls which is ideal for freeze drying, vacuum drying or lyophilization applications Vacuum Controller with onboard ramp rate recipe control. Set up to 8 recipes based on time and pressure setpoints. Dashboard pushbutton control for START, STOP functionality for each channel allows you to automatically vent or isolate your system with a push of a button Ideal for automating and simplifying vacuum chamber pressure control. SIMPLE – SIMPLIFY YOUR LAB & CONTROL MORE WITH LESS Applications: vacuum chamber (from 1 liter to 1000 liters) research, vacuum ovens/vacuum drying, vacuum furnaces, large scale food processing, microwave drying, composites, rotary evaporators, falling film systems Fine control of target vacuum pressure for more precise processing and research Enables using reliable and long lasting rotary vane pumps & dry scroll pumps in applications where diaphragmpumps were previously required Keeps vacuum pumps near their base pressure resulting in greater longevity NIMBLE – MAXIMIZES THROUGHPUT & PUMPDOWN SPEED Largest flow paths available to insure maximum flow for faster evaporation Maximize throughput and pump down speed with a 20 mm vacuum path (almost full KF25 orifice) AUTOMATIC PROCESS – PRECISION CONTROL & INTUITIVE DESIGN Automatic Vacuum Process Controller | precise automated control with programmable recipes and graphing of vacuum levels Innovative valve control performs both proportional throttle and bleed vacuum control (vent to atmosphere) The integrated bleed design allows you to quickly vent to atmosphere to stop bumping during processing Numerical readings right on the LCD screen and one touch buttons: VENT, CLOSE (isolate, close all valves) and FULL VAC (fully opens the valve for vacuum pump and closes the vent valve) SNAP Vacuum Controller Wetted Material Options Aluminum (6061) wetted surfaces Stainless steel (304) wetted surfaces Measurement and Control Range: 1 Torr to 775 Torr (standard) Need millitorr range?: SNAP has a RJ45 Port for adding an additional sensor to extend the measurement range. We recommend the addition of the DCP Quantum to be able to monitor and control from 0.01 Torr to 1000 Torr.   DigiVac SNAP Data Sheet  DigiVac SNAP Operational Manual  DigiVac SNAP Quick Start Guide 

    $5,100.00$4,650.00

  • CHEMTEK W5 Neutral Bleaching Clay

    CHEMTEK W5 Neutral Bleaching Clay

    CHEMTEK W5 Neutral Bleaching Clay W5 is a neutral bleaching clay specialized for the removal of heavy metals. While most sorbents will remove heavy metals, the acids involved in the activation process could cause desorption. By neutralizing the clay processors can take advantage of the increased surface area without any risk of desorption. W5 SDS W5 Technical Data Sheet  

    $40.00 - $1,800.00

  • CHEMTEK W4 Pesticide Remdiation Bleaching Clay

    CHEMTEK W4 Pesticide Remediation Bleaching Clay

    CHEMTEK W4 Pesticide Remediation Bleaching Clay W4 is an alkaline bleaching clay specialized for the removal of pesticides, chlorophyll, free fatty acids, and oxidized compounds. It removes pesticides through adsorption and hydrolysis. Pesticides undergo alkaline hydrolysis, in which a pH greater than 7 causes chemical degradation of certain pesticides in the presence of ions. W4 SDS W4 Technical Data Sheet  

    $50.00 - $2,250.00

  • CHEMTEK W3 Acid Activated Bleaching Clay

    CHEMTEK W3 Acid Activated Bleaching Clay

    CHEMTEK W3 Acid Activated Bleaching Clay W3 is a highly active adsorptive clay designed for difficult to bleach oils. It has a high cation exchange capacity paired with high moisture content making it ideal for adsorption of impurities such as chlorophyll, carotenes, heavy metals, phospholipids, soaps, and other impurities. W3 SDS W3 Technical Data Sheet

    $50.00 - $2,250.00

  • CHEMTEK W2 Heat Activated Natural Bleaching Clay

    W2 Heat Activated Natural Bleaching Clay

    CHEMTEK W2 Heat Activated Natural Bleaching Clay W2 is a natural bleaching clay offering mild yet efficient results. It is heat activated to increase its adsorptive power without the use of any acids. The lack of acid prevents terpene isomerization and keeps the terpene profile the same while also slowing the oxidation rate of the oil thus increasing its shelf life. W2 is heavier in bulk density giving it lower oil retention. W2 SDS W2 Technical Data Sheet

    $50.00 - $2,250.00

  • CHEMTEK W1 Acid Activated Refinement Clay

    CHEMTEK W1 Acid Activated Refinement Clay

    Chemtek W1  W1 (TM) is an acid activated bentonite clay adsorbent specific for the removal of chlorophyll, heavy metals, and fats. W1 is very effective at bleaching and refining while preserving the terpenes present in the oil. Unlike other clays, the ability to remove soaps and free fatty acids which are produced during the bleaching process reduces the amount of clay needed to bleach. W1 SDS W1 Technical Data Sheet 

    $50.00 - $2,250.00

  • NEOCISION Cold Trap with Pump - ETL Rated - (-40c)

    NEOCISION Cold Trap with Pump - ETL Rated - (-40c)

    NEOCISION Cold Trap with Pump - ETL Rated - (-40c) Looking for a cold trap and small application chiller? The BVV™ CT40 features a 2-in-1 use with a cold trap function and built in circulating system for small batch temperature control.  Cold Trap Function Use the BVV™ CT40 to condense vapors down to -40°C before they reach your vacuum pump. This prolongs the life of the vacuum system, reduces the need to change oil frequently, and efficiently traps vapors otherwise lost to evaporation such as terpenes. Common applications include short path distillation, rotary evaporation, reactor setups, or any other application where volatile vapors can damage your vacuum pump. Chiller Function Use the BVV™ CT40 for small batch temperature control down to -40°C. Switch out the cold trap configuration with solid lid to turn your cold trap into a chiller. Common applications include condensing coils, small vessel setups, heat exchangers. Operating 2-in-1 Simultaneously Use the BVV™ CT40 as a cold trap and chiller. The unit can be used with the cold trap configuration and circulating function simultaneously. Commonly used as for chilling applications with no additional heat load.     BVV™-CTC40-WP Power Requirement AC 110V +/- 10% / 60Hz Relative Humidity < 85% Cooling Capacity 400W Refrigerant R404A Cold Trap Capacity 3 x 300ml Cold Trap Barb Dia. 10mm Reservoir Capacity 6.8L External Dimensions 305 x 485 x 635mm Weight 149 lbs     Call in to see how we can pair this unit with your setup Please Note: This device is designed for operation on its own independent circuit breaker. For best results, do not use this device on a breaker shared with other equipment. ***Notice to Customers: All units are inspected for broken glass or parts before the unit is shipped. If unit arrives damaged or glass is broken (this does not include minor imperfections or scuffs in glassware), Customer MUST contact BVV™ within 3 days of delivery to file a claim and receive a replacement part. If customer DOES NOT contact BVV™ within 3 days of delivery responsibility for replacement parts falls on the customer and they must pay for replacement pieces.*** ***Glassware Safety Disclaimer: BVV™ is not responsible for failure of glassware which must be inspected before and after every use because it may eventually develop imperfections or damage through normal usage, mishandling, and stress caused by temperature variations. If an imperfection or damage is noted while inspecting the glassware DO NOT use the glassware because it can fail causing bodily harm or damage to the surrounding area.***

    $3,100.00

  • 1LB EVO Closed Loop Extractor

    1LB EVO Closed Loop Extractor

    1LB EVO Closed Loop Extraction System (System comes with 1 yr. limited warranty) The EVO series of 1LB closed-loop extractors was designed with the evolution of stand-up extractors in mind. The aim of the EVO series of extractors is to provide unparalleled utility and ease of use within a traditional stand-up design.  The EVO series was designed to tackle the two most common plights with stand-up extractors, difficulty in extract harvesting, and integration of adsorbent filtration. The Evo series accomplishes both through the use of its elevated extract pour spout and its optional inline color remediation column. Beyond the elevated pour spout and optional inline color remediation column. The EVO series aims to provide unbridled safety and solvent recovery speed through the integration of ASME pressure relief valves on both the material column and collection base standard and full bore 1/2" recovery lines found on the professional and elite models. The 1lb EVO comes complete with a top fill injection manifold including a compound gauge, a 125 psi ASME pressure relief valve, and two full bore ball valves complete with 2x 1/4" Male JIC connections on the explorer and both 1/4" & 1/2" Male JIC connections on the professional and elite models. Just below the injection manifold, all 1lb EVO models have a solvent dispersion plate that evenly disperses solvent into the 3"x 24" 1lb material column which is enclosed by 2x 100 micron Buna-N mesh gaskets.  Both the Professional and Elite models come complete with an inline 3" x 6" color remediation column just below the material column with a 300-gram media capacity and a filter stack utilizing both a 5 micron & 1 micron sintered disk. Professional and Elite models also include 25-micron filter paper and a 500-gram sample of Pure-Flo B80   Below the 1lb material column, and optional inline color remediation column the 1lb Evo includes the jacketed and elevated pour spout collection base that allows for easy extract harvesting and speedy solvent recovery.  The elevated base can accommodate up to a 5:1 solvent-to-biomass ratio and accept a standard round pyrex dish or a small parchment paper boat below the pour spout.  Upon completion of the run, extract removal is made easy by simply draining the extract from the elevated extract pour spout. Both the professional and elite models have increased solvent recovery capability from the jacketed collection base through full-bore 1/2" recovery MJIC connections and stainless steel recovery hoses.  ***Note: Solvent not included with systems unless ordered separately. Any order with butane WILL NOT SHIP EXPEDITED.*** ***DISCLAIMER: This unit is intended for LEGAL purposes only, to be used in accordance with local laws and ordinances. Use only in extremely well-ventilated areas. Check with your local fire marshal for guidance when operating indoors. KEY BENEFITS Meets or exceeds all industry-listed standards Versatile in running butane, propane, and other blended solvents Perfect for mid to large-scale extraction/production facilities  Faster run times and less degradation in the process Easy extract harvesting using the elevated pour spout Inline color remediation Extractor Configuration: Explorer: Our standard, most economical setup, perfect for the entry-level extractor on a budget. Comes with the jacketed and elevated collection base and 1/4" Male JIC connections on the injection manifold and collection base. This model does not include the inline color remediation column or 1/2" Male JIC recovery/ injection connections. The Explorer model is forward compatible and can be easily upgrad*This model does not come with a heated circulator*ed to include 1/2" lines and the inline color remediation column.  Professional: This model includes all the features of the explore model with the increased functionality of an inline color remediation column Just under the material column that comes with 25micron filter paper and a 500-gram sample of b80, an upgraded stainless steel recovery tank, and a full bore 1/2" Male JIC connection included on the injection manifold and collection base. *This model does not come with a heated circulator* Elite: The Elite series is the premium version of the Professional. It features the same 1/2" Male JIC, and inline color remediation column upgrades. But also includes the EVO recovery tank that allows for pre-chilling and speedy recovery of solvent.  *This model does not come with a heated circulator* Certified: The Certified series is the certified version of the elite. It features the same 1/2" Male JIC, and inline color remediation column upgrades. But also includes the EVO recovery tank that allows for pre-chilling and speedy recovery of solvent. This Model is 22 State certified and includes an Infield Verification by PRV Engineers within the purchase price. States include but are not limited to: Alabama, Arizona, Arkansas, California, Colorado, Connecticut, Florida, Illinois, Kansas, Louisiana, Maine, Massachusetts, Missouri, Nevada, North Carolina, Oklahoma, Oregon, Texas, Vermont, Washington, West Virginia, and Wyoming *This model does not come with a heated circulator*   Explorer Professional Elite Jacketed & Elevated pour spout collection base Jacketed & Elevated pour spout collection base Inline Color remediation column 25-micron filter paper 500 gram B80 sample 1/2" recovery lines 30# Stainless steel Recovery Tank Jacketed & Elevated pour spout collection base Inline Color remediation column 25-micron filter paper 500 gram B80 sample 1/2" recovery & Injection lines EVO Recovery Tank     Unit Includes: Full bore injection Manifold complete with a compound gauge,125 PSI ASME pressure relief valve, and 2x 1/4" MJIC connections (1x1/2" MJIC connection on professional & elite models) 3"x24" 1lb Material column with solvent dispersal plate. 3"x6" Color remediation column 300g gram media capacity complete with a filter stack including 5 micron and 1 micron sintered disks (Professional & Elite model) 25-micron ashless filter paper (Professional & Elite) Jacketed & elevated collection base with extract pour spout 6" hemispherical collection base lid complete with borosilicate sight glasses, a compound gauge, 125 PSI ASME pressure relief valve, and full bore ball valves with MJIC Connections. 30# LP storage and recovery tank (Explorer) 30# stainless steel LP tank (Professional) & EVO Recovery tank (Elite) (1) 1/4" 72" FJIC Stainless Steel Injection hose (Explorer & Professional) 1/2" 96" FJIC Stainless Steel Injection Hose (Elite) (1) 1/4" 60" FJIC Stainless Steel Recovery Hose (Explorer) 1/2" 60" FJIC Stainless Steel Recovery Hose (Professional & Elite) High-pressure clamps Specifications: 3"x 24" 304 Stainless Steel Material Column-1lb capacity (450g) 316 Stainless Steel Fully Encapsulated Miniature Ball Valves System Rated to 150PSI Multiple 37 degree FJIC port connections 304 Stainless jacketed & elevated collection base Tri-Clamps at all interfaces make for a high pressure/standard pressure, easy-clean unit BUNA-N Gaskets are designed for Oil Processing Temp range -40-200F, and have superior solvent resistance Construction: All components are made of 304 Stainless Steel. Max Vacuum -29.9inHg High Polish Interior   *Note: Column capacity may vary depending on the density of packed material and packing density. Capacity is calculated using the industry standard of 4.2g/in3. This is the upper limit for column capacity. Low density, uncut, and/or lightly packed material can reduce capacity by 50%. For best results, we recommend to tightly pack coarse ground material.

    $1,650.00 - $6,850.00

  • Sale -45% Jacketed Collection Spool

    Jacketed Collection Spool

    8"x 52" Jacketed Collection Spool   This spool is 8" in diameter x 52" in length with 4" Tri-Clamp ports on either end. The top has 1/4" and 1/2" NPT ports to add a gauge and pressure relief directly to the vessel. The spool has a closed jacket with 1/2" NPT ports that make this spool ideal to use as a collection tank on a rack-mounted system.

    $1,100.00$600.00

  • PTFE WFE Wipers - 3 Pack

    PTFE WFE Wipers - 3 Pack

    PTFE WFE Wipers   These wipers are designed for wiped film evaporators spinning counterclockwise. Pack of 3 Dimensions: 15.375L x .38W x .42D

    $350.00

  • Sale -44% Glas-Col 22L Stir Mantle

    Glas-Col 22L Stir Mantle

    Glas-Col 22L Stir Mantle Safely and accurately heat solutions used in various distillations in laboratory and scientific applications Apply heat directly and uniformly to containers, such as round bottom flasks More accurate than hot plates and safer than Bunsen burners Controllers can be purchased individually Accommodates 22L spherical flasks     Specifications & Description Max Flask Size (mL) 22000 Min Stirrer Speed (rpm) 100 Max Stirrer Speed (rpm) 1850 Max temperature (° F) 752 Max temperature (° C) 400 Power (VAC) 115 Power (watts) 1540 Height (in) 14 Diameter (in) 6.875 Outside Diameter (OD) (in) 19 Description Stirring/Heating Mantle, 22L Spherical Flask; 115V

    $1,600.00$900.00

  • SSP - Union Elbow - 3/8" Duolok

    SSP - Union Elbow - 3/8" Duolok

    Stainless Steel SSP -Union Elbow 3/8" Duolok

    $42.00

  • Sale -60% Safety Tools - The Extractor's Kit (AlCu)

    Safety Tools - The Extractor's Kit (AlCu)

    The Extractor’s Safety Tool Kit These tools are forged out of 100% Aluminum Bronze (GB EX IIB). The material hardness is 20-30 HRC, which is still very durable for normal day to day work. They will not generate a spark when knocked against or dropped on steel parts. We have optimized the kit to only include what you will need on our equipment. This kit includes: -Combination Wrenches: 5/8” ¾” -Double End Wrenches: 19/17 mm 17/14 mm 14/10 mm -200mm Adjustable Wrench -250mm Adjustable Wrench -3/8” Drive Socket Wrench -Sockets:  ½ 14mm 5/8 11/16 ¾ -Allen Keys: 3/16  ¼ -Phillips #2 Screwdriver-6mm Flathead Screwdriver-500g Cross-Peen Hammer

    $500.00$200.00

  • Sale -30% 22L Glas-Col Mantle and Controller

    22L Glas-Col Mantle and Controller

    22L Glas-Col Mantle and Controller   Specifications Material Aluminum Housed Max Temperature C 400 Height (in) 10 Outside Diameter (od)(in) 13.66 Capacity 22L Volts 115 Watts 2 @ 770 Includes: Separable 4-2ft., 2-wire cord and locking connector

    $1,500.00$1,050.00

  • Julabo Thermal C10

    Julabo Thermal C10

    Julabo Thermal C10  JULABO Thermal bath fluids are ideally suited for all of your temperature control applications and guarantee safe and reliable operation. Choosing the proper bath fluid is critical for the best temperature control results. Viscosity, oxidation characteristics and heat transfer of Thermal fluids are matched specifically with each JULABO temperature control unit. JULABO Thermal bath fluids have been carefully selected and optimized for maximum performance with JULABO instruments. Thermal C10 is a clear 10 cSt silicone fluid rated for use in open bath JULABO units with a working temperature range of -20…+160 °C. Care should be taken to observe atmospheric moisture condensation in the bath fluid with prolonged sub-ambient operation in humid environments. Water and silicone fluids are not miscible. Operation at the maximum temperature for heating applications will result in vapor formation. Vapor formation at elevated temperatures is a normal occurrence for silicone fluids. The upper temperature limit of the fluid is lower than the fluid flashpoint.    

    $1,596.00 - $3,170.00

  • Julabo Adapter 8891609 M16x1 f to NPT 1/2″ f

    Julabo Adapter 8891609 M16x1 f to NPT 1/2″ f

    Julabo Adapter 8891609 M16x1 f to NPT 1/2″ f 2 Adapters M16x1 f. to NPT 1/2″ f.

    $256.00

  • Tef-Flex PTFE / EPDM Unitized Sanitary Tri-Clamp Gasket

    Tef-Flex PTFE / EPDM Unitized Sanitary Tri-Clamp Gasket

    Tef-Flex Sanitary Tri-Clamp Gasket Tef-Flex: A Tef-Flex sanitary gasket’s contact surface is a layer of PTFE grafted to an EPDM rubber inner core. This totally bonded construction provides an exceptionally pure and incredibly flexible seal. By grafting the elastomer with a layer of PTFE, Tef-Flex will behave like an elastomer but will prevent product contamination, service interruptions and clean-up costs associated with traditional elastomer seals. The PTFE grafted elastomer in a Tef-Flex sanitary gasket will maintain I.D. without re-torquing or leaking. Key Features: Excellent resistance to almost all chemicals Excellent Temperature Range Excellent Cleanability due to PTFE (Teflon)  Excellent Flexibility Sizes Available: 1.5" 2" 2.5" 3" 4" Chemical Compatibility: Butane A - Excellent Propane (liquified) A - Excellent Alcohols: Amyl A - Excellent Benzyl A - Excellent Butyl A - Excellent Diacetone A - Excellent Ethyl A - Excellent Hexyl A - Excellent Isobutyl A - Excellent Isopropyl A - Excellent Methyl A - Excellent Octyl A - Excellent Propyl A - Excellent Disclaimer: BVV Recommends no more than a -40F Operating Temperature and is not responsible for the user running their system with incompatible chemicals.

    $19.00 - $46.00

  • Tef-Steel 316LStainless Steel /  PTFE Sanitary Tri-Clamp Gasket

    Tef-Steel 316LStainless Steel / PTFE Sanitary Tri-Clamp Gasket

    Tef-Steel 316L Stainless Steel / PTFE Sanitary Tri-Clamp Gasket Tef-Steel: a 50/50 blend of modified PTFE and 316L atomized and passivated stainless steel, Tef-Steel delivers leak-proof, perfect surface performance with outstanding durability in SIP (steam in place), CIP (clean in place), WFI (water for injection) and hot oil applications. Tef-Steel is ideal for sanitary steam pipe connections in extreme temperatures ranging from -300°F to 500°F. The superior strength of Tef-Steel provides extended uptime because it eliminates cold flow and creep preventing maintenance problems and downtime. Key Features: Excellent resistance to almost all chemicals Excellent Temperature Range (-300°F to 500°F) Excellent Cleanability due to PTFE (Teflon) and Stainless Steel Sizes Available: 1" 1.5" 2" 2.5" 3" 4" 6" 8" 10" 12" Chemical Compatibility: Butane A - Excellent Propane (liquified) A - Excellent Alcohols: Amyl A - Excellent Benzyl A - Excellent Butyl A - Excellent Diacetone A - Excellent Ethyl A - Excellent Hexyl A - Excellent Isobutyl A - Excellent Isopropyl A - Excellent Methyl A - Excellent Octyl A - Excellent Propyl A - Excellent

    $7.00 - $245.00

  • Carbon Chemistry ZeoClear™ Y

    Carbon Chemistry APG Granular (ZeoClear Y)

    Carbon Chemistry APG Granular (ZeoClear Y) A selective zeolitic clay adsorbent designed for precise separation control. This thermally activated attapulgite-zeolite composite features a unique alkaline surface chemistry that provides measured adsorption rates, making it ideal for gentle refinement processes. Its carefully engineered pore structure and granular stability allow for controlled removal of specific compounds while preserving desired characteristics of the process stream. Key Features: Micron Size 250-595um Attapulgite granular media, alkaline medium Easy handling, fast flow, color improvement General product improvement with high contaminant absorptivity Color Remediation In-Line Filtration Hot Scrub Recirculate Granular Media FAQ: How do I use granular media? Zeolite adsorbents can be used inline during extraction with LPG solvents or in a hot scrub with non-polar solvents of higher BP like Heptane Is this a replacement for powders? The answer depends on what your processing goals are e.g. color removal, pesticide remediation, etc. Each adsorbent for filtration media will have its own unique set of properties including pH, pore size, polarity, surface area that make certain adsorbents more suitable to certain uses. Can I mix granular media and powders? Yes, you can either mix powders with granular media or place the granular media on top a bed of powdered media. This will however result in a more restricted flow which will require additional pressure to pass your solution through your filter cake. Do I need to bake the media? Media does not need to be baked prior to use but can be only superficial water will be removed which may improve performance. To remove superficial moisture, bake for 8hrs at 200C (392F) How do I know how much media to use? This will depend on a few variables such as the amount of your starting material, the age of your starting material, and desired color of your final product.  How does the media need to be stored? before and after use. Before use; Keep container tightly closed and dry; store in a cool place. After use; Store in a well-ventilated area, this media is saturated with flammable/explosive solvent and can self-ignite if not not handled properly. Is the media safe to handle without PPE (Personal Protective Equipment)? Breathing must be protected when large quantities are decanted without local exhaust ventilation. When workers face exposure to dust exceeding the occupational exposure limits they must use appropriate certified respirators. Wear a NIOSH-certified (or equivalent) particulate respirator. What micron size filters are required? / The media is larger but are there fines? The media might be large but there are fine dust particles (about 5 million per lb.) that can get carried away in your solution and require separation. We suggest stacking a 5-micron filter on top of a 1-micron filter which will help keep your flow slow as well as filtering out any fine dust particles. The media didn't work, what did I do wrong? There is an exceptionally good chance you did not restrict your solvent flow enough. Try again with a much slower flow through your filter. Another variable you might consider adjusting is solvent temperature. Colder solvent will pull less lipids and waxes which can impede the efficiency of the adsorbent.   Note:  Bulk Bags and Bulk sizes are non-stocked items and will be ordered as needed and carry a several week lead time and require a forklift or pallet jack

    $40.00 - $8,000.00

  • CANA-SIL60™ Silica Gel 60A Chromatographic Grade 40-63 micron (230-400 Mesh)

    CANA-SIL60™ Silica Gel 60A Chromatographic Grade 40-63 micron (230-400 Mesh)

    CANA-SIL60™ Silica Gel Silicon Dioxide 60A Chromatographic, Extraction CRC Grade Cana-Sil™ is an Optimized silica gel for extractions.  This powdered silica gel (silicon dioxide) for use in chromatography batch extractions and decolorizations. Cana-Sil60 can also be used as a general adsorbent for impurities. Optimized particle size, surface area, pH, and purity make it a particularly useful material for the separation of small molecules, peptides, lipids, alkaloids, and a variety of other compounds.  Silica Gel is particularly useful to use layered on top of your bentonite to remove plant gums and waxes.  CANA-SIL60 Technical Data Sheet CANA-SIL60 Safety Data Sheet CANA-SIL60 Certificate of Analysis Key Specs: Particle Size: 40-63 Micron (230-400 Mesh) Pore Volume: 0.6-0.8 mL/g Loss on Drying: ≤ 2.0 wt% pH: 6.5-7.5 Empirical Formula: SiO2 Use: Chromatography Purification Hazard Statement: No ingredients are hazardous according to OSHA criteria CAS# 112926-00-8

    $28.00 - $8,100.00

  • Extend Protection Plan - Best Value Vacs

    $0.49 - $229.00

  • Extend Protection Plan - Best Value Vacs

    $1.29 - $699.00

  • Extend Protection Plan - Best Value Vacs

    $0.89 - $439.00

  • Sale -44% Neocision Spectra Explorer LED Grow Light

    Neocision Spectra Explorer LED Grow Light

    Neocision Spectra Explorer LED Grow Light Explorer Our Explorer grow light fixture is designed for a full grow cycle with maximized red for increased photosynthesis. Ideal for 2’ x 4’ tent environments for increased consistency and yield. Neocision Spectra Explorer Cutsheet Performance, Specs, Ranking FEATURES: Efficacy up to 2.56 Micromoles / J @120 VAC Industry Leading Horticulture LEDs RJ Port for Plug and Play Control Systems Fast and Easy Installation 7 Year Limited Warranty on Fixture 8 Year Limited Warranty on Driver Looking for bulk purchases? We offer volume discounts and other value adding services with our partners at RSX Enterprises. Call (331-281-0154) and speak with a rep for more information.   SPECTRUM AND EFFICACY PPF Efficacy: 2.56 at 120VAC Photon Flux (µmol/s) (400-700nm): 870 Photon Flux Blue (µmol/s) (400-500nm): 161 Photon Flux Green (µmol/s) (500-600nm): 355 Photon Flux Red (µmol/s) (600-700nm): 355 Total Blue/Red - Energy Bands: 516 % Blue: 18.51% % Green: 40.76% % Red: 40.73% POWER Power Consumption: 340W AC Driver: Sosen Power Factor: >0.95 Surge Protection: 6 KV 120V: 2.90 A 208V: 1.75 A 240V: 1.51 A 277V: 1.31 A DIMENSIONS Fixture Size (driver mounted on the fixture): (L) 43.7” x (W) 22” x (H) 4.1” Fixture Size (without driver): (L) 43.7” x (W) 22” x (H) 1.6” Power Supply Dimension: (L)18.7” X (W) 4.4” X (H) 2.4” Driver Net Weight: 6 lb. Fixture Net Weight: 6 lb. OTHER Mounting Height >6” above canopy Beam Angle 120 Degree Input Voltage 100 - 277 VAC Manual Dimming Knob Yes Built In Control Ports Yes Standard Power Cord (Extensions available) AWG 18, 6 Foot Standard Plug 120 VAC - NEMA 5-15P Substitute Plugs (Upon request at order for bulk purchases) 240 VAC, 277 VAC, Pigtails Adjustable Height Hanging Kit Included Yes Fixture Warranty 7 Years Limited Driver Warranty 8 Years Limited ETL Safety Certified Conforms to UL 1598:2018 Ed.4Certified to CSA C22.2#250.0:2018 Ed.4*ETL Safety Certified No. 5020070

    $375.00$210.00

  • BVV™ SF6S 6CFM Single Stage Spark Free Vacuum Pump

    SF6S 6CFM Single Stage Spark Free Vacuum Pump

    BVV™ SF6S 6CFM Two Stage Spark Free Vacuum Pump This is the BVV™ SF6S 6CFM Two Stage Spark Free Vacuum Pump Please Refer to these charts for vacuum specifications at altitude and conversions: Vacuum at Altitude Chart Vacuum Conversion Chart Key Features: Internal Check Valve Spark Free Construction Oil Mist Filter Cap Larger Oil Reservoir for longer Oil life Lightweight Rubber Feet for noise dampening Reliable, Economical and Efficient.   Models BVVSF6S BVVSF6D BVVSF12D Stage 1 2 2 Ultimate Vacuum (Microns) 75 15 15 Refrigerant Classes A1 Non-Toxic, Non Flammable A2 Non-Toxic, Low Flammability A3 Non-Toxic, High Flammability Dimensions (in) 12.4 x 4.8 x 10.16 13 x 5.5 x 10.7 15 x 6.3 x 11.22 Weight (lbs) 16.5 24.3 33.6 Free Air Displacement 6.4 CFM 6.4 CFM 12.8 CFM Motor Size (HP) RPM 1 HP 3440 RPM Oil Capacity 14.5oz / 410ml 19oz / 410ml 20.6oz / 680ml Voltage 110V 60 Hz Power Cord Hard Wired 3m / 9.8' Power Cord Power Switch Ignition Proof On / Off Switch Operating Temperature Range 32F to 125 F (0C to 52C) Gas Ballast Valve No Yes Yes Intake Fittings Stainless Steel Inlet Fitting with 1/4" SAE & 3/8" JIC Male Ports Pump Warranty Information • Customers using solvents such as stabilization resins (MinWax™, Gator Venom™ etc.), alcohol and other polar solvents must use the vacuum pumps in conjunction with a cold trap for evacuations in excess of 5 minutes. (Excludes Cactus Juice™)• If the consumer is using the pump for prolonged periods of time exceeding 5 minutes we require that a cold trap is used or the pump warranty is void.• These stabilization resins have the ability to break down the internal components of the pump that are plastic resulting in a seized motor voiding all warranties. • When evacuation exceeds 5 minutes these solvents begin to vaporize and then re-condense in the vacuum pump reservoir. Once enough solvent re-condenses in the pump displacing the oil the plastic internal components may begin to warp, melt or seize. The use of a cold trap will condense the vapors prior to making their way to the vacuum pump preventing pump damage due to excessive use. Furthermore, Minwax Wood Hardener™ is not to be used with any vacuum pumps, EVER. (A seized motor will result within the first use.)• To prevent these issues from happening to your process, change the Oil after each vacuum pump use, Even if the use time is only 5min.

    $210.00

  • BVV™ SF12D 12CFM Two Stage Spark Free Vacuum Pump

    SF12D 12CFM Two Stage Spark Free Vacuum Pump

    BVV™ SF12D 12CFM Two Stage Spark Free Vacuum Pump This is the BVV™ SF12D 12CFM Two Stage Spark Free Vacuum Pump. Please Refer to these charts for vacuum specifications at altitude and conversions: Vacuum at Altitude Chart Vacuum Conversion Chart Key Features: Internal Check Valve Spark Free Construction Oil Mist Filter Cap Larger Oil Reservoir for longer Oil life Lightweight Rubber Feet for noise dampening Reliable, Economical and Efficient. Models BVVSF6S BVVSF6D BVVSF12D Stage 1 2 2 Ultimate Vacuum (Microns) 75 15 15 Refrigerant Classes A1 Non-Toxic, Non Flammable A2 Non-Toxic, Low Flammability A3 Non-Toxic, High Flammability Dimensions (in) 12.4 x 4.8 x 10.16 13 x 5.5 x 10.7 15 x 6.3 x 11.22 Weight (lbs) 16.5 24.3 33.6 Free Air Displacement 6.4 CFM 6.4 CFM 12.8 CFM Motor Size (HP) RPM 1 HP 3440 RPM Oil Capacity 14.5oz / 410ml 19oz / 410ml 20.6oz / 680ml Voltage 110V 60 Hz Power Cord Hard Wired 3m / 9.8' Power Cord Power Switch Ignition Proof On / Off Switch Operating Temperature Range 32F to 125 F (0C to 52C) Gas Ballast Valve No Yes Yes Intake Fittings Stainless Steel Inlet Fitting with 1/4" SAE & 3/8" JIC Male Ports Pump Warranty Information • Customers using solvents such as stabilization resins (MinWax™, Gator Venom™ etc.), alcohol and other polar solvents must use the vacuum pumps in conjunction with a cold trap for evacuations in excess of 5 minutes. (Excludes Cactus Juice™)• If the consumer is using the pump for prolonged periods of time exceeding 5 minutes we require that a cold trap is used or the pump warranty is void.• These stabilization resins have the ability to break down the internal components of the pump that are plastic resulting in a seized motor voiding all warranties. • When evacuation exceeds 5 minutes these solvents begin to vaporize and then re-condense in the vacuum pump reservoir. Once enough solvent re-condenses in the pump displacing the oil the plastic internal components may begin to warp, melt or seize. The use of a cold trap will condense the vapors prior to making their way to the vacuum pump preventing pump damage due to excessive use. Furthermore, Minwax Wood Hardener™ is not to be used with any vacuum pumps, EVER. (A seized motor will result within the first use.)• To prevent these issues from happening to your process, change the Oil after each vacuum pump use, Even if the use time is only 5min.

    $495.00

  • BVV™ V9D 9CFM Two Stage Vacuum Pump

    V9D 9CFM Two Stage Vacuum Pump

    BVV™ V9D 9CFM Two Stage Vacuum Pump This is the BVV™ V9D 9CFM Two Stage Vacuum Pump. Please Refer to these charts for vacuum specifications at altitude and conversions: Vacuum at Altitude Chart Vacuum Conversion Chart Key Features: Internal Check Valve Oil Mist Filter Cap Larger Oil Reservoir for longer Oil life Lightweight Rubber Feet for noise dampening Reliable, Economical and Efficient.   Models BVV4D BVV7S BVV9D Stage 2 1 2 Ultimate Vacuum (Microns) 15 75 15 Refrigerant Classes A1 Non-Toxic, Non Flammable Dimensions (in) 12.4 x 4.8 x 10.16 12.4 x 4.8 x 10.16 15 x 6.3 x 11.22 Weight (lbs) 19.4 16.5 32 Free Air Displacement 4.3 CFM 6.4 CFM 8.5 CFM Motor Size (HP) RPM 1 HP 3440 RPM Oil Capacity 10oz / 300ml 14.5oz / 410ml 24oz / 680ml Voltage 110V 60 Hz Power Cord Hard Wired 3m / 9.8' Power Cord Power Switch Standard On / Off Operating Temperature Range 32F to 125 F (0C to 52C) Gas Ballast Valve Yes No Yes Intake Fittings Stainless Steel Inlet Fitting with 1/4" SAE & 3/8" JIC Male Ports Pump Warranty Information Customers using solvents such as stabilization resins (MinWax™, Gator Venom™ etc.), alcohol and other polar solvents must use the vacuum pumps in conjunction with a cold trap for evacuations in excess of 5 minutes. (Excludes Cactus Juice™) If the consumer is using the pump for prolonged periods of time exceeding 5 minutes we require that a cold trap is used or the pump warranty is void. These stabilization resins have the ability to break down the internal components of the pump that are plastic resulting in a seized motor voiding all warranties. When evacuation exceeds 5 minutes these solvents begin to vaporize and then re-condense in the vacuum pump reservoir. Once enough solvent re-condenses in the pump displacing the oil the plastic internal components may begin to warp, melt or seize. The use of a cold trap will condense the vapors prior to making their way to the vacuum pump preventing pump damage due to excessive use. Furthermore, Minwax Wood Hardener™ is not to be used with any vacuum pumps, EVER. (A seized motor will result within the first use.) To prevent these issues from happening to your process, change the Oil after each vacuum pump use, Even if the use time is only 5min.

    $430.00

  • BVV™ V7S 7CFM Single Stage Vacuum Pump

    V7S 7CFM Single Stage Vacuum Pump

    V7S 7CFM Single Stage Vacuum Pump This is the BVV™ V7S 7CFM Single Stage Vacuum Pump. Please Refer to these charts for vacuum specifications at altitude and conversions: Vacuum at Altitude Chart Vacuum Conversion Chart Key Features: Internal Check Valve Oil Mist Filter Cap Larger Oil Reservoir for longer Oil life Lightweight Rubber Feet for noise dampening Reliable, Economical and Efficient. Models BVV4D BVV7S BVV9D Stage 2 1 2 Ultimate Vacuum (Microns) 15 75 15 Refrigerant Classes A1 Non-Toxic, Non Flammable Dimensions (in) 12.4 x 4.8 x 10.16 12.4 x 4.8 x 10.16 15 x 6.3 x 11.22 Weight (lbs) 19.4 16.5 32 Free Air Displacement 4.3 CFM 6.4 CFM 8.5 CFM Motor Size (HP) RPM 1 HP 3440 RPM Oil Capacity 10oz / 300ml 14.5oz / 410ml 24oz / 680ml Voltage 110V 60 Hz Power Cord Hard Wired 3m / 9.8' Power Cord Power Switch Standard On / Off Operating Temperature Range 32F to 125 F (0C to 52C) Gas Ballast Valve Yes No Yes Intake Fittings Stainless Steel Inlet Fitting with 1/4" SAE & 3/8" JIC Male Ports Pump Warranty Information Customers using solvents such as stabilization resins (MinWax™, Gator Venom™ etc.), alcohol and other polar solvents must use the vacuum pumps in conjunction with a cold trap for evacuations in excess of 5 minutes. (Excludes Cactus Juice™) If the consumer is using the pump for prolonged periods of time exceeding 5 minutes we require that a cold trap is used or the pump warranty is void. These stabilization resins have the ability to break down the internal components of the pump that are plastic resulting in a seized motor voiding all warranties. When evacuation exceeds 5 minutes these solvents begin to vaporize and then re-condense in the vacuum pump reservoir. Once enough solvent re-condenses in the pump displacing the oil the plastic internal components may begin to warp, melt or seize. The use of a cold trap will condense the vapors prior to making their way to the vacuum pump preventing pump damage due to excessive use. Furthermore, Minwax Wood Hardener™ is not to be used with any vacuum pumps, EVER. (A seized motor will result within the first use.) To prevent these issues from happening to your process, change the Oil after each vacuum pump use, Even if the use time is only 5min.

    $250.00

  • BVV™ V4D 4CFM Two Stage Vacuum Pump

    V4D 4CFM Two Stage Vacuum Pump

    BVV™ V4D 4CFM Two Stage Vacuum Pump This is the BVV™ V4D 4CFM Two Stage Vacuum Pump used in botanical extraction. Please refer to these charts for vacuum specifications at altitude and conversions: Vacuum at Altitude Chart Vacuum Conversion Chart Key Feature  Internal Check Valve Oil Mist Filter Cap Larger Oil Reservoir for longer oil life Lightweight Rubber Feet for noise dampening Reliable, economical, and efficient Models BVV4D BVV7S BVV9D Stage 2 1 2 Ultimate Vacuum (Microns) 15 75 15 Refrigerant Classes A1 Non-Toxic, Non Flammable Dimensions (in) 12.4 x 4.8 x 10.16 12.4 x 4.8 x 10.16 15 x 6.3 x 11.22 Weight (lbs) 19.4 16.5 32 Free Air Displacement 4.3 CFM 6.4 CFM 8.5 CFM Motor Size (HP) RPM 1 HP 3440 RPM Oil Capacity 10oz / 300ml 14.5oz / 410ml 24oz / 680ml Voltage 110V 60 Hz Power Cord Hard Wired 3m / 9.8' Power Cord Power Switch Standard On / Off Operating Temperature Range 32F to 125 F (0C to 52C) Gas Ballast Valve Yes No Yes Intake Fittings Stainless Steel Inlet Fitting with 1/4" SAE & 3/8" JIC Male Ports   Pump Warranty Information Customers using solvents such as stabilization resin, rotaries (MinWax™, Gator Venom™ etc.), alcohol and other polar solvents must use the vacuum pumps in conjunction with a cold trap for evacuations in excess of 5 minutes. (Excludes Cactus Juice™) If the consumer is using the pump for prolonged periods of time exceeding 5 minutes we require that a cold trap is used or the pump warranty is void. These stabilization resins have the ability to break down the internal components of the pump that are plastic resulting in a seized motor voiding all warranties. When evacuation exceeds 5 minutes these solvents begin to vaporize and then re-condense in the vacuum pump reservoir. Once enough solvent re-condenses in the pump displacing the oil the plastic internal components may begin to warp, melt or seize. The use of a cold trap will condense the vapors prior to making their way to the vacuum pump preventing pump damage due to excessive use. Furthermore, Minwax Wood Hardener™ is not to be used with any vacuum pumps, EVER. (A seized motor will result within the first use.) To prevent these issues from happening to your process, change the Oil after each vacuum pump use, Even if the use time is only 5min.

    $340.00

  • 1" FNPT X 1.5" Tri-Clamp Top Cap

    1" FNPT X 1.5" Tri-Clamp Top Cap

    1" FNPT X 1.5" Tri-Clamp Top Cap     These tri-clamp end caps: Have a 1" Female NPT connection Are made of 304 stainless steel

    $20.00

  • TRS21 Upgraded Cylinder Replacement Kit, w/Shims Fits BVV4CYL & BVV2CYL

    TRS21 Upgraded Cylinder Replacement Kit, w/Shims Fits BVV4CYL & BVV2CYL

    BVV-6     Included in this kit: (2x) Anodized Aluminum Cylinders and Viton Gaskets, Plus 6 shims (2x .004" and 2x .002") use for top dead center adjustment of the cylinders to dial in the displacement (recommended displacement .008").  This upgrade kit can be used for the following recovery pumps: CPS TRS21 Anti-spark/explosion pump (including the SS model from BVV) BVV 2 Cylinder Butane Recovery Pump ITS/ETL to ANSI/ISA Certified BVV 4 Cylinder Butane Recovery Pump ITS/ETL to ANSI/ISA Certified - Requires 2 kits because this unit has 4 cylinders. BVV 4 Cyl & 2 Cyl Pump Seal Rebuild Instructions  

  • Sale -41% Glas-Col 2 L Stir Mantle

    Glas-Col 2 L Stir Mantle

    Glas-Col 2 L Stir Mantle   Specifications Material aluminum housed Max temperature C 400 Height (in) 6 Outside Diameter (od)(in) 12 Capacity 2 L Volts 115 Watts 500 Includes: Separable 4-ft., 2-wire cord and locking connector.

    $1,100.00$650.00

  • Glas-Col Thermocouple Type "J" Mini Plug

    Glas-Col Thermocouple Type "J" Mini Plug

    Glas-Col Thermocouple Type "J" Mini Plug   D x L :  1/4" x 4" Lead Length: 72"

    $70.00

  • Glas-Col Thermocouple Type "J"

    Glas-Col Thermocouple Type "J"

    1/4" x 12" 72" leads, mini plug

    $135.00

  • Sale -50% Glas-Col Vapor Monitor

    Glas-Col Vapor Monitor

    Glas-Col Vapor Monitor   motor vapor temperature or other processes  audible alarm - high, low, t/c break  digital display      Specifications TC Type "J" MUST BE ORDERED SEPARATELY Range 0 - 999 C Dimensions 4" W x 4" D x 4" H Volts 120 Includes: 6' attached power cord and grid support bracket

    $300.00$150.00


You have seen 672 out of 1746 products

Login

Forgot your password?

Don't have an account yet?
Create account