The EVO series of 1LB closed-loop extractors was designed with the evolution of stand-up extractors in mind. The aim of the EVO series of extractors is to provide unparalleled utility and ease of use within a traditional stand-up design. The EVO series was designed to tackle the two most common plights with stand-up extractors, difficulty in extract harvesting, and integration of adsorbent filtration. The Evo series accomplishes both through the use of its elevated extract pour spout and its optional inline color remediation column. Beyond the elevated pour spout and optional inline color remediation column. The EVO series aims to provide unbridled safety and solvent recovery speed through the integration of ASME pressure relief valves on both the material column and collection base standard and full bore 1/2" recovery lines found on the professional and elite models.
The 1lb EVO comes complete with a top fill injection manifold including a compound gauge, a 125 psi ASME pressure relief valve, and two full bore ball valves complete with 2x 1/4" Male JIC connections on the explorer and both 1/4" & 1/2" Male JIC connections on the professional and elite models.
Just below the injection manifold, all 1lb EVO models have a solvent dispersion plate that evenly disperses solvent into the 3"x 24" 1lb material column which is enclosed by 2x 100 micron Buna-N mesh gaskets.
Both the Professional and Elite models come complete with an inline 3" x 6" color remediation column just below the material column with a 300-gram media capacity and a filter stack utilizing both a 5 micron & 1 micron sintered disk. Professional and Elite models also include 25-micron filter paper and a 500-gram sample of Pure-Flo B80
Below the 1lb material column, and optional inline color remediation column the 1lb Evo includes the jacketed and elevated pour spout collection base that allows for easy extract harvesting and speedy solvent recovery.
The elevated base can accommodate up to a 5:1 solvent-to-biomass ratio and accept a standard round pyrex dish or a small parchment paper boat below the pour spout. Upon completion of the run, extract removal is made easy by simply draining the extract from the elevated extract pour spout.
Both the professional and elite models have increased solvent recovery capability from the jacketed collection base through full-bore 1/2" recovery MJIC connections and stainless steel recovery hoses.
***Note: Solvent not included with systems unless ordered separately. Any order with butane WILL NOT SHIP EXPEDITED.***
***DISCLAIMER: This unit is intended for LEGAL purposes only, to be used in accordance with local laws and ordinances. Use only in extremely well-ventilated areas. Check with your local fire marshal for guidance when operating indoors.
KEY BENEFITS
Meets or exceeds all industry-listed standards
Versatile in running butane, propane, and other blended solvents
Faster run times and less degradation in the process
Easy extract harvesting using the elevated pour spout
Inline color remediation
Extractor Configuration:
Explorer:Our standard, most economical setup, perfect for the entry-level extractor on a budget. Comes with the jacketed and elevated collection base and 1/4" Male JIC connections on the injection manifold and collection base. This model does not include the inline color remediation column or 1/2" Male JIC recovery/ injection connections. The Explorer model is forward compatible and can be easily upgrad*This model does not come with a heated circulator*ed to include 1/2" lines and the inline color remediation column.
Professional:This model includes all the features of the explore model with the increased functionality of an inline color remediation column Just under the material column that comes with 25micron filter paper and a 500-gram sample of b80, an upgraded stainless steel recovery tank, and a full bore 1/2" Male JIC connection included on the injection manifold and collection base. *This model does not come with a heated circulator*
Elite: The Elite series is the premium version of the Professional. It features the same 1/2" Male JIC, and inline color remediation column upgrades. But also includes the EVO recovery tank that allows for pre-chilling and speedy recovery of solvent. *This model does not come with a heated circulator*
Certified:The Certified series is the certified version of the elite. It features the same 1/2" Male JIC, and inline color remediation column upgrades. But also includes the EVO recovery tank that allows for pre-chilling and speedy recovery of solvent. This Model is 22 State certified and includes an Infield Verification by PRV Engineers within the purchase price. States include but are not limited to: Alabama, Arizona, Arkansas, California, Colorado, Connecticut, Florida, Illinois, Kansas, Louisiana, Maine, Massachusetts, Missouri, Nevada, North Carolina, Oklahoma, Oregon, Texas, Vermont, Washington, West Virginia, and Wyoming*This model does not come with a heated circulator*
Explorer
Professional
Elite
Jacketed & Elevated pour spout collection base
Jacketed & Elevated pour spout collection base
Inline Color remediation column
25-micron filter paper
500 gram B80 sample
1/2" recovery lines
30# Stainless steel Recovery Tank
Jacketed & Elevated pour spout collection base
Inline Color remediation column
25-micron filter paper
500 gram B80 sample
1/2" recovery & Injection lines
EVO Recovery Tank
Unit Includes:
Full bore injection Manifold complete with a compound gauge,125 PSI ASME pressure relief valve, and2x1/4" MJIC connections (1x1/2" MJIC connection on professional & elite models)
3"x24" 1lb Material column with solvent dispersal plate.
3"x6" Color remediation column 300g gram media capacity complete with a filter stack including 5 micron and 1 micron sintered disks (Professional & Elite model)
25-micron ashless filter paper (Professional & Elite)
Jacketed & elevated collection base with extract pour spout
6" hemispherical collection base lid complete with borosilicate sight glasses, a compound gauge, 125 PSI ASME pressure relief valve, and full bore ball valves with MJIC Connections.
30# LP storage and recovery tank (Explorer) 30# stainless steel LP tank (Professional) & EVO Recovery tank (Elite)
Tri-Clamps at all interfaces make for a high pressure/standard pressure, easy-clean unit
BUNA-N Gaskets are designed for Oil Processing Temp range -40-200F, and have superior solvent resistance
Construction: All components are made of 304 Stainless Steel.
Max Vacuum -29.9inHg
High Polish Interior
*Note: Column capacity may vary depending on the density of packed material and packing density. Capacity is calculated using the industry standard of 4.2g/in3. This is the upper limit for column capacity. Low density, uncut, and/or lightly packed material can reduce capacity by 50%. For best results, we recommend to tightly pack coarse ground material.
The EVO series of 1LB closed-loop extractors was designed with the evolution of stand-up extractors in mind. The aim of the EVO series of extractors is to provide unparalleled utility and ease of use within a traditional stand-up design. The EVO series was designed to tackle the two most common plights with stand-up extractors, difficulty in extract harvesting, and integration of adsorbent filtration. The Evo series accomplishes both through the use of its elevated extract pour spout and its optional inline color remediation column. Beyond the elevated pour spout and optional inline color remediation column. The EVO series aims to provide unbridled safety and solvent recovery speed through the integration of ASME pressure relief valves on both the material column and collection base standard and full bore 1/2" recovery lines found on the professional and elite models.
The 1lb EVO comes complete with a top fill injection manifold including a compound gauge, a 125 psi ASME pressure relief valve, and two full bore ball valves complete with 2x 1/4" Male JIC connections on the explorer and both 1/4" & 1/2" Male JIC connections on the professional and elite models.
Just below the injection manifold, all 1lb EVO models have a solvent dispersion plate that evenly disperses solvent into the 3"x 24" 1lb material column which is enclosed by 2x 100 micron Buna-N mesh gaskets.
Both the Professional and Elite models come complete with an inline 3" x 6" color remediation column just below the material column with a 300-gram media capacity and a filter stack utilizing both a 5 micron & 1 micron sintered disk. Professional and Elite models also include 25-micron filter paper and a 500-gram sample of Pure-Flo B80
Below the 1lb material column, and optional inline color remediation column the 1lb Evo includes the jacketed and elevated pour spout collection base that allows for easy extract harvesting and speedy solvent recovery.
The elevated base can accommodate up to a 5:1 solvent-to-biomass ratio and accept a standard round pyrex dish or a small parchment paper boat below the pour spout. Upon completion of the run, extract removal is made easy by simply draining the extract from the elevated extract pour spout.
Both the professional and elite models have increased solvent recovery capability from the jacketed collection base through full-bore 1/2" recovery MJIC connections and stainless steel recovery hoses.
***Note: Solvent not included with systems unless ordered separately. Any order with butane WILL NOT SHIP EXPEDITED.***
***DISCLAIMER: This unit is intended for LEGAL purposes only, to be used in accordance with local laws and ordinances. Use only in extremely well-ventilated areas. Check with your local fire marshal for guidance when operating indoors.
KEY BENEFITS
Meets or exceeds all industry-listed standards
Versatile in running butane, propane, and other blended solvents
Faster run times and less degradation in the process
Easy extract harvesting using the elevated pour spout
Inline color remediation
Extractor Configuration:
Explorer:Our standard, most economical setup, perfect for the entry-level extractor on a budget. Comes with the jacketed and elevated collection base and 1/4" Male JIC connections on the injection manifold and collection base. This model does not include the inline color remediation column or 1/2" Male JIC recovery/ injection connections. The Explorer model is forward compatible and can be easily upgrad*This model does not come with a heated circulator*ed to include 1/2" lines and the inline color remediation column.
Professional:This model includes all the features of the explore model with the increased functionality of an inline color remediation column Just under the material column that comes with 25micron filter paper and a 500-gram sample of b80, an upgraded stainless steel recovery tank, and a full bore 1/2" Male JIC connection included on the injection manifold and collection base. *This model does not come with a heated circulator*
Elite: The Elite series is the premium version of the Professional. It features the same 1/2" Male JIC, and inline color remediation column upgrades. But also includes the EVO recovery tank that allows for pre-chilling and speedy recovery of solvent. *This model does not come with a heated circulator*
Certified:The Certified series is the certified version of the elite. It features the same 1/2" Male JIC, and inline color remediation column upgrades. But also includes the EVO recovery tank that allows for pre-chilling and speedy recovery of solvent. This Model is 22 State certified and includes an Infield Verification by PRV Engineers within the purchase price. States include but are not limited to: Alabama, Arizona, Arkansas, California, Colorado, Connecticut, Florida, Illinois, Kansas, Louisiana, Maine, Massachusetts, Missouri, Nevada, North Carolina, Oklahoma, Oregon, Texas, Vermont, Washington, West Virginia, and Wyoming*This model does not come with a heated circulator*
Explorer
Professional
Elite
Jacketed & Elevated pour spout collection base
Jacketed & Elevated pour spout collection base
Inline Color remediation column
25-micron filter paper
500 gram B80 sample
1/2" recovery lines
30# Stainless steel Recovery Tank
Jacketed & Elevated pour spout collection base
Inline Color remediation column
25-micron filter paper
500 gram B80 sample
1/2" recovery & Injection lines
EVO Recovery Tank
Unit Includes:
Full bore injection Manifold complete with a compound gauge,125 PSI ASME pressure relief valve, and2x1/4" MJIC connections (1x1/2" MJIC connection on professional & elite models)
3"x24" 1lb Material column with solvent dispersal plate.
3"x6" Color remediation column 300g gram media capacity complete with a filter stack including 5 micron and 1 micron sintered disks (Professional & Elite model)
25-micron ashless filter paper (Professional & Elite)
Jacketed & elevated collection base with extract pour spout
6" hemispherical collection base lid complete with borosilicate sight glasses, a compound gauge, 125 PSI ASME pressure relief valve, and full bore ball valves with MJIC Connections.
30# LP storage and recovery tank (Explorer) 30# stainless steel LP tank (Professional) & EVO Recovery tank (Elite)
Tri-Clamps at all interfaces make for a high pressure/standard pressure, easy-clean unit
BUNA-N Gaskets are designed for Oil Processing Temp range -40-200F, and have superior solvent resistance
Construction: All components are made of 304 Stainless Steel.
Max Vacuum -29.9inHg
High Polish Interior
*Note: Column capacity may vary depending on the density of packed material and packing density. Capacity is calculated using the industry standard of 4.2g/in3. This is the upper limit for column capacity. Low density, uncut, and/or lightly packed material can reduce capacity by 50%. For best results, we recommend to tightly pack coarse ground material.