END OF YEAR SUPER SALE UP TO 20% OFF STORE WIDE (12/22-1/5)

Solvent Recovery Kit - 2 Gallon (Compares to ExtractCraft Source Turbo)

Description

Solvent Recovery Kit - 2 Gallon

The BVV Solvent Recovery Kit makes it easy for anyone to recover and reuse their extraction solvent. The kit uses a vacuum pump to lower the boiling point of the solvent, then will use a cooling source such as ice or dry ice to turn the vaporized solvent back into liquid form. This kit has a few different seals, be sure that all materials are compatible with your solvent. These materials include:

  • Viton (FKM)
  • Silicone
  • EPDM / Butyl

Please verify before using that all these materials are compatible with your solvent. For an easy resistance chart please visit the Cole Parmer link below:

https://www.coleparmer.com/chemical-resistance

What's included:

No Pump   BVV-2G

  • Condensing Coil
  • Hosing
  • Glass Vacuum Chamber Lids/hardware
  • Receiving Vessel Chamber
  • Air Inlet Filter
  • Evaporating Vessel
  • Induction Heating Plate

With Pump   BVV-2G-V40  

  • Condensing Coil
  • Hosing
  • Glass Vacuum Chamber Lids/hardware
  • Receiving Vessel Chamber
  • Air Inlet Filter
  • Evaporating Vessel
  • Induction Heating Plate
  • Chemically Resistant Vacuum Pump

No Evap/ Pump   BVV-2G-NEV

  • Condensing Coil
  • Hosing
  • Glass Vacuum Chamber Lids/hardware
  • Receiving Vessel Chamber
  • Air Inlet Filter
  • Evaporating Vessel LID with Universal Gasket

      *NOTE: This option will fit any pot with an outer diameter of 6.5" - 10.5" 

 

Not included in the kit, you will need:

  • Ice Tray
  • Ice Bucket
  • Ice or dry ice

A 5 gallon bucket and disposable aluminum catering tray will suffice, however a container with a drain plug or valve would be ideal to easily drain the water produced throughout the process.

This kit requires a vacuum pump to operate, we would recommend a chemically resistant diaphragm vacuum pump. We include a 1/4" JIC and 1/4" barb connection to connect to your vacuum pump. The included hosing is 1/4" ID Tygon tubing to easily attach to a barbed vacuum pump.

 

Running the Unit

Caution: Unit uses flammable solvents. Use caution while operating unit. ALWAYS OPERATE IN EXTREMELY WELL VENTILATED AREAS

  1. Place your solution into the Evaporating Vessel. This can be done by:
    1. removing the lid and pouring the solution into the vessel
    2. Using the vacuum pump to suck the liquid mixture through the Liquid Inlet Port. Using this method, you can use a Micro-Cap filter in-line to remove solid particulate.
  2. Close the Liquid Inlet Port valve and Air Inlet valve
  3. Add ice to the bucket and tray. A drain valve built in to the ice bucket and tray would help to drain water later in the test.
  4. Open the Vacuum Pump valve and turn on the Vacuum Pump
  5. Turn on the Heat Plate. An induction heating plate is recommended
  6. Replace ice as needed throughout the run
  7. When recovery is completed, close the Vacuum Pump valve and turn off the Vacuum Pump.
  8. Open the Air Inlet valve and release the vacuum pressure from the chamber. Use the included micron filter to prevent contaminants from entering the vessel.
  9. Turn off the Heat Plate and allow the solute in the Evaporating Vessel to come down to a safe temperature. Removing the solute is easiest when it is still warm.
  10. Remove the solvent from the Receiving Vessel.
  11. Once the kit is cooled down, use clean ethanol to wipe down the sealing surfaces for the next run.

For a more detailed operating procedure please be sure to check out this website: HOME EXTRACTION BY ICHIBANCRAFTER : https://extractcrafter.com/2022/05/10/diy-vacuum-still-part-2-putting-together-and-operation/

Solvent Recovery Kit - 2 Gallon (Compares to ExtractCraft Source Turbo)

Product form

SKU: SRK-2G-NEV

$642.00

    • Want it cheaper? Call us for a wholesale or processor discount. 331-281-0154
    Financing Available

    Use one of partners to pay over time.

    Description

    Solvent Recovery Kit - 2 Gallon

    The BVV Solvent Recovery Kit makes it easy for anyone to recover and reuse their extraction solvent. The kit uses a vacuum pump to lower the boiling point of the solvent, then will use a cooling source such as ice or dry ice to turn the vaporized solvent back into liquid form. This kit has a few different seals, be sure that all materials are compatible with your solvent. These materials include:

    • Viton (FKM)
    • Silicone
    • EPDM / Butyl

    Please verify before using that all these materials are compatible with your solvent. For an easy resistance chart please visit the Cole Parmer link below:

    https://www.coleparmer.com/chemical-resistance

    What's included:

    No Pump   BVV-2G

    • Condensing Coil
    • Hosing
    • Glass Vacuum Chamber Lids/hardware
    • Receiving Vessel Chamber
    • Air Inlet Filter
    • Evaporating Vessel
    • Induction Heating Plate

    With Pump   BVV-2G-V40  

    • Condensing Coil
    • Hosing
    • Glass Vacuum Chamber Lids/hardware
    • Receiving Vessel Chamber
    • Air Inlet Filter
    • Evaporating Vessel
    • Induction Heating Plate
    • Chemically Resistant Vacuum Pump

    No Evap/ Pump   BVV-2G-NEV

    • Condensing Coil
    • Hosing
    • Glass Vacuum Chamber Lids/hardware
    • Receiving Vessel Chamber
    • Air Inlet Filter
    • Evaporating Vessel LID with Universal Gasket

          *NOTE: This option will fit any pot with an outer diameter of 6.5" - 10.5" 

     

    Not included in the kit, you will need:

    • Ice Tray
    • Ice Bucket
    • Ice or dry ice

    A 5 gallon bucket and disposable aluminum catering tray will suffice, however a container with a drain plug or valve would be ideal to easily drain the water produced throughout the process.

    This kit requires a vacuum pump to operate, we would recommend a chemically resistant diaphragm vacuum pump. We include a 1/4" JIC and 1/4" barb connection to connect to your vacuum pump. The included hosing is 1/4" ID Tygon tubing to easily attach to a barbed vacuum pump.

     

    Running the Unit

    Caution: Unit uses flammable solvents. Use caution while operating unit. ALWAYS OPERATE IN EXTREMELY WELL VENTILATED AREAS

    1. Place your solution into the Evaporating Vessel. This can be done by:
      1. removing the lid and pouring the solution into the vessel
      2. Using the vacuum pump to suck the liquid mixture through the Liquid Inlet Port. Using this method, you can use a Micro-Cap filter in-line to remove solid particulate.
    2. Close the Liquid Inlet Port valve and Air Inlet valve
    3. Add ice to the bucket and tray. A drain valve built in to the ice bucket and tray would help to drain water later in the test.
    4. Open the Vacuum Pump valve and turn on the Vacuum Pump
    5. Turn on the Heat Plate. An induction heating plate is recommended
    6. Replace ice as needed throughout the run
    7. When recovery is completed, close the Vacuum Pump valve and turn off the Vacuum Pump.
    8. Open the Air Inlet valve and release the vacuum pressure from the chamber. Use the included micron filter to prevent contaminants from entering the vessel.
    9. Turn off the Heat Plate and allow the solute in the Evaporating Vessel to come down to a safe temperature. Removing the solute is easiest when it is still warm.
    10. Remove the solvent from the Receiving Vessel.
    11. Once the kit is cooled down, use clean ethanol to wipe down the sealing surfaces for the next run.

    For a more detailed operating procedure please be sure to check out this website: HOME EXTRACTION BY ICHIBANCRAFTER : https://extractcrafter.com/2022/05/10/diy-vacuum-still-part-2-putting-together-and-operation/

    Returns & Delivery

    When will my order be delivered?

    We ship worldwide. Your order will be packaged really carefully and delivered wherever you want. Delivery takes between 2-4 business days. You will receive an e-mail after ordering with more information about the delivery.

    Can I return my product?

    Orders can be returned or exchanged within 30 days of receiving the parcel, providing they are in original resalable condition.

    What can I do if my item (or part of it) is damaged?

    We work hard to deliver your items without damage. Orders can be returned or exchanged within 30 days of receiving the parcel, providing they are in original resalable condition.

    Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?
      Create account