All products
J-KEM DVR-200-EV Digital Vacuum Regulator
J-KEM DVR-200-EV Digital Vacuum Regulator The DVR-200-EV has the same stainless steel pressure transducer inside, but the vacuum valve is outside of the controller. The value of this design is that the vacuum valve can be cleaned or replaced much easier than the valve in the classic DVR-200. Some applications, like distillations or stripping large volumes of solvent, can leave residues inside the valve which causes it to fail. Replacing the vacuum valve is the most frequent repair that J-KEM performs on the DVR-200. Replacing the valve in the classic DVR-200 is difficult and must be returned to J-KEM for repair. With the EV version, the user can disassembled the valve and wash it out, or even replace it in under 5 minutes. For large distillations or botanical applications, J-KEM recommends the DVR-200-EV. No Mercury 100% digital pressure entry and control Wetted parts are 100% stainless steel and Teflon Vacuum ramping feature eliminates bumping Resists: All organic solvents Acids Bases Water Specifications: 100 watts. Vacuum fittings: 1/8″ NPTM. Warranty: Electronics 2 Years, Vacuum Valve 6 months (void if damaged by chemical buildup)
$1,638.00
SSP 1/2" Compression Fitting Parts
SSP 1/2" Compression Fitting Parts ISSD8N: Duolok Tube Fittings, 1/2 in. Nut ISSD8FF: SSP® Duolok® Front Ferrule, FF Series, Nominal Size: 1/2 in, 316 Stainless Steel ISSD8BF: SSP® Duolok® Back Ferrule, BF Series, Nominal Size: 1/2 in, 1/2 in ID, 316 Stainless Steel
$3.00 - $9.00
Harvest Right Premier Vacuum Pump
Harvest Right Premier Vacuum Pump Technical Specifications Oil: Robinair Premium High Vacuum Pump Oil or JB Industries Black Gold Vacuum Pump Oil Only DC Motor Energy Efficient Voltage: Standard, 110v, 60Hz Dimensions: 16.3″ x 6″ x 12.1″ Weight: 32lbs Noise: 52 decibels Product Comparison: Premier Oil Pump vs Standard Oil Pump Oil Changes: This new Premier Pump rarely needs to have the oil changed or filtered. The pump has a gas ballast feature that makes it so water does not stay in the oil. Because of this, the oil in the pump will be pristine and clear, even after 30 or more batches. You simply won’t need to change the oil until you have run 20 or more batches. Whereas, the oil in the Standard Vacuum Pump needs to be changed and filtered every 4 or 5 batches (when using the new 3/8 inch vacuum hose). You should only replace the oil in this pump with Robinair Premium High Vacuum Pump Oil (or with JB Industries Black Gold Vacuum Pump Oil). These may be purchased from Harvest Right, Amazon, and other locations. Do not use Dairyland vacuum pump oil in the Premier pump. Vacuum Pressure: Under cold and hot conditions the Premier Pump will pull a deeper vacuum than the Standard Pump. Under cold conditions the difference is .05 Pascal for the Premier Pump and .08 Pascal for the Standard Pump. Whereas, under warm conditions the difference is much greater: .05 Pascal for the Premier Pump and 2.05 Pascal for the Standard Pump.Hence, the Premier Pump is especially not affected by warm, ambient conditions. When temperatures rise, it will pull a vacuum far better than the Standard Pump. The Premier Pump is just not affected by outside heat. It pulls the same deep vacuum even when it is in a warm environment. Noise: The Premier Pump is substantially quieter than the Standard Pump, 52 decibels versus 64 decibels. The Industrial Pump at 52 decibels is about the same as a refrigerator. Oil Mist Filter: Both pumps come with an oil mist filter. However, the Premier Pump’s oil mist filter allows for no oil spray at all and it will last much longer. Power Use: The Premier Pump uses less power than the Standard Pump (187 watts versus 218 watts). Amperage: Under hot conditions at ultimate vacuum pressure the Standard Pump pulls 2.1 amps while the Premier Pump only pulls 1.7 amps. Hence, the Premier Pump is more efficient. Weight: The Premier Pump is easier to move around as it weighs 5 pounds less than the Standard Pump (32 lbs. versus 37 lbs.) Life: The Premier Pump is more durable and will last longer than the Standard Pump.
$795.00
Replacement O-ring for Chemglass 1/4" Thermometer Adapters
Black circular replacement op-ring for chemglass 1/4" thermometer adapters.
$1.25
475L Jacketed Stainless Steel Centrifuge with Explosion Proof Motor and Siemens Controller - 150Lbs Max Capacity
475L Ethanol Wash/Dry Centrifuge with Explosion Proof Motor and Controller Notice to Customer: This unit has 4 lift points (one in each corner) and requires a forklift with a 6000lb+ rating to lift it. Due to the size and weight of this item a custom freight quote will be required. If purchased, BVV will contact the customer to provide shipping options and their price. Confirming logistics will require a 2-3 week lead time. Industrial Centrifuges are used to separating liquids from solids and this style of centrifuge excels at alcohol extraction by forcefully separating the alcohol from the biomass. Key Features: Siemens Touch Screen Controller Explosion Proof Controller Housing and Motor Agitation and Spin Dry Modes Max 800 RPM with Gradual Speed Stepping 430 Separation Factor Multiple Connection Ports/Sizes. High Polish Stainless Steel Components Shock absorbing legs Vacuum Jacket with Two 1.5" Tri-Clamp Fittings Pre-wired and Tested for Easy Installation Specifications Capacity 475L Drum Dimensions 47.24" (1200mm) Diameter x 16-3/4" (425mm) Deep Max Capacity 440lbs (200Kg) Speed 800 rpm Separation Factor 430 Electrical 240V 3Ø Weight 5600lbs (2540Kg) Exterior Dimensions 85" x 65" x 49" (2150mm x 1650mm x 1250mm) Viewport Diameter Dual 9" Viewing Ports Connection Size(s): 4" Tri-Clamp Drain Port 1.5" Tri-clamp Jacket Port x 2 1.5" / 2.5" Tri-Clamp Top Ports 1/4" FNPT Top Port KF25 Top Port
$39,500.00
MAXTRAP105 -105°C Vacuum Cold Trap, 120V
MAXTRAP105 -105°C Vacuum Cold Trap, 120V Cascade’s MAXTRAP105 is not an ordinary lab-grade cold trap. Cascade has integrated features necessary for time-sensitive, high-throughput, production-focused vacuum purging or drying applications. MAXTRAP105 Cold Trap Includes: Cascade’s COLDWELL 304 Stainless Steel Trap Insert (Patent pending baffle system) 3 Quart Capacity (2839 ml) Viton Gasket for Vacuum Integrity Labconco -105°C Refrigerated Base Green CFC / HFC Free Refrigerants Power Cord 3mm Neoprene Insulator Cap Requires 800ml (~ 3.5 cups) of a transfer fluid such as ethanol. Not Included. Cascade recommends: ethanol, glycol, cryo-cool fluids Quality Made in USA 1 Year Warranty Connection Lines and hardware: 4′ of 1″ Diameter Vacuum Tubing with KF-25 Flanges on each side. KF-25 clamps, centering rings for the connection tube MAXTRAP Tips: Safety At very cold temperatures, solvents and even oxygen can re-condense back into liquid. This is potentially explosive. Liquid oxygen is a light blue color and can condense into a cold trap if a pump has sucked air through the trap when the trap is very cold. Always follow your standard operating procedures and safety guidelines. Don’t Stop: Keep Processing while trap is being reclaimed, cleaned, refreshed Cold traps can become full or the captured material freezes and blocks flow. For high moisture, outgassing, 24 hour processing/vacuum purging consider adding a second, spare COLDWELL trap. The secondary COLDWELL can be dropped into place so processing continues while the full trap is cleaned, defrosted. Quick Start Up Tips: Remove shipping foam from reservoir bottom prior to use Fill reservoir with 800ml (+/-3.5 cups) ethanol to marked line Monitor ethanol levels inside reservoir Allow at least 30 mins for trap to cool Keep side vents clear. Allow at least 4″ for airflow Monitor interior of stainless trap for clogging Short tube – attach to vacuum pump Tall tube – attach to vacuum oven MAXTRAP105 Differences: The key to quality cold trap performance is: time, surface area, and temperature. Time: Most cold traps have very narrow inlets and outlets, slowing down your process. Not Cascade’s MAXTRAP105! Full KF25 inlet and outlet connections never reduce flow. Surface Area: Most cold traps have glass or a smaller surface area to collect the matter your vacuum pump would otherwise ingest. Cascade’s MAXTRAP105 surface area is a patent pending series of filter baffles inside the COLDWELL stainless trap. Specifications Coldwell Stainless Trap KF25 Inlet & Outlet 3 Quart Capacity (2839 mliters) Viton Gasket Neoprene Insulator Cap Labconco -105°C Mechanical Base 115V / 1ph / 3 AMP (60Hz) Cord Included CFC / HCFC Free Refrigerants Dimensions inches 24.1 W x 23.9 D x 12.6 H cm 34.3 x 59.7 x 30.5 *Requires approximately 800ml (~ 3.5 cups) of transfer fluid(ethanol, glycol, cryo-cool fluids) Connections 1 each 4′ KF-25 flanged vacuum rated line 1 each KF-25 Centering Ring 1 each KF-25 Clamp Weight COLDWELL Stainless Trap: 14 lbs Mechanical Base: 139 lbs Shipping Weight: 190 lbs Additional Resources: Download Specs Download Supplemental Manual NTRL Certifications -105C Refrigerated Base Safety Certification
$9,950.00
Half Ton - High Purity USA 70/30% N-Butane/Propane Blend - 99.5% Guaranteed
Half Ton - High Purity USA 70/30% N-Butane/Propane Blend - 99.5% Guaranteed DISCLAIMER(S): This unit is intended for LEGAL purposes only, to be used in accordance with local laws and ordinances. Use only in WELL VENTILATED AREAS! Notice: This item will ship via Freight ONLY. This tank requires a CGA 510 fitting - Sold Separately BVV™ always recommends distillation of every solvent before use. *Actual liquid weight is 483LB California now prohibits the retail sale of any Non-Odorized butane in quantities larger than 150ml. If you are not a retail purchaser you can call in to place an order. Permitted Sales Include the Following: Medical Collectives or Cooperatives operating under CA Health & Safety Code Section 11362.775 Persons licensed to perform volatile solvent extraction activity under CA Bus & Prof Code Division 10 Manufacturers, wholesalers, resellers, or retailers solely for the purpose of resale High purity 70/30% N-Butane/Propane is USA sourced, and guaranteed to be 99.5% pure. This instrument grade solvent helps to produce a higher quality extract by reducing mystery oils and contaminants. Solvent comes in a DOT refillable LP tank with liquid withdrawal valve (Diptube). This product is clean, colorless and odorless. *Actual liquid weight is 483LB BVV™ Dual Blend SDS Due to FAA regulations, solvent tanks cannot be safely transported via means other than ground. Any order that has solvent will not be shipped in an expedited fashion. If an order with solvent is combined with any other items and chosen to be expedited, that entire order will ship via UPS Ground/Freight. We will not split up any orders and ship them separately. If a customer is wanting to expedite specific items and order solvent, 2 separate orders (1 for the solvent and 1 for the expedited items) will need to be placed in order to do so. Solvents do not ship to Hawaii, Puerto Rico, or any other US Territory outside of the contiguous 48 States. Shipping Solvent to Alaska may ONLY ship via freight and will be required to travel through Canada. We have this policy in place to ensure safety when transporting solvents, and to prevent any issue with shipping times for our customers.
$2,940.00
True Terpenes Gelato
True Terpenes Gelato Fragrance: Sweet Pungent Berry-like Creamy Effects: Soothing Euphoric Happy Giggly This hybrid is named for its dessert-like aroma. A blend of Sunset Sherbet and Thin Mint Girl Scout Cookies, Gelato is a potent deliverer of restfulness and euphoria. Sweet, pungent, flowery scents bring creativity. Also known as “Larry Bird.” Storage Requirements: Keep in original container, lid securely tightened and away from heat, open flames, sunlight, combustible materials and hot surfaces. No Smoking. Store in a cool dry place. Improper storage can cause terpenes to degrade. Dilution: Terpene Strain & Flavor-Infused Strain Profiles, Effects-Based Terpene Profiles & Terpene Flavors:The Terpene products above must be diluted prior to use. (1-5% by total volume). Terpenes are oil soluble and mix well with plant extracts, coconut oil, and more. Viscosity Extract Modifier: The Terpene product above must be diluted prior to use. (1-3% by total volume). Terpenes are oil soluble and mix well with plant extracts, coconut oil, and more. Handle With Care: Can cause skin irritation, do not use PRIOR to dilution. -Specific Certificates: Product Specification Certificate of Analysis Safety Data Sheet Food Safety Company-Specific Certificates: ISO 9001:2015 GMP Certification FSSC 22000
$121.50 - $2,250.00
5L Neocision Short Path Distillation Turnkey Kit
5L Neocision Short Path Distillation Turnkey Kit This unit carries a 2 day lead time. The 5L Premium Distillation Turnkey Setup features our 5L Distillation Kit with P5 Distillation Head and USA made glass. Every component in this turnkey is made for precision, throughput, and repeatable results. Also included is our Pro Series Corrosion Resistant Two Stage Vacuum Pump giving you extreme power and depth with a long lifespan, the Bullseye Precision Vacuum Gauge from Digivac which is the most rugged and dependable vacuum gauge on the market, and a BVV 19L Heated Circulator for maximum condensation of vapors. You will also receive a Dewar Style Glass Cold Trap to keep all volatiles and solvents out of your vacuum system. This Turnkey Setup gives you everything needed to perform distillation at the highest level. The Premium Turnkey Kit Includes: 5L Neocision Kit with P5 Distillation Head KF-25 x 1/4" Barb Adapter Dewar Style Glass Cold Trap Bullseye Precision Vacuum Gauge BVV 19L MX Heated Circulator Pro Series 21.2CFM Corrosion Resistant Two Stage Vacuum Pump Distillation Quick Start Guide This guide gives basic quick start instructions for distillation systems. It is intended to provide a starting point for learning the process. Parameters should be adjusted to suit specific needs, Before beginning distillation, ensure the following steps have been taken: Vacuum Pump is in good working order. Pump should be run against dry load to allow internals to warm up. Oil should be clear. Cloudy or dark oil should be changed. All glass components are in good working order and ready to be assembled A winterization and degassing procedure has been done to prepare oil for distillation Once all three of these steps have been completed, you are ready to begin distilling. Begin by placing stir bar in boiling flask and then load your material. This should be done using a funnel. A small amount of alcohol in the oil will give it a thinner consistency making it easier to transfer. Assemble all glassware and ensure each joint is properly greased. Do not use too much, as the vacuum pressure might pull some grease into the system. To ensure a full seal, spread grease in a circular motion by rotating glassware Attach circulator to condenser and set temperature to 50C. Allow circulator to reach temperature before beginning distillation. Connect vacuum pump to manifold. The manifold will allow you to isolate each individual component as well as let atmosphere into and out of the system. Connect receiving cow to cold trap. Connect cold trap to manifold. Connect vacuum gauge to manifold. At this point, ensure all connections are correct. Also ensure receiving cow is positioned to collect the first fraction in the far-left receiving flask. Circulator should be at its set temperature. Turn on vacuum pump to begin process. Turn on heat and set to 60C. Vacuum pump will begin to pull down and temperature will begin to rise. Watch the gauge to monitor vacuum pressure and stability. Start stir slower and increase speed with temperature. Once you are close to 60C, increase the temperature 20 degrees. Continue to raise the heat incrementally in 20-degree steps, increasing the set temperature as you near your set point. Increase temperatures incrementally until you reach 220C. You will see your first fraction somewhere between 180C and 190C or slightly before. This is the “heads” fraction. You will move to your second fraction when you see an increased reaction in the head, a slight color change toward golden, as well as a thickening of distillate. When this fraction hits, allow the distillate to “self-clean” the head for a minute or two then, rotate the cow to the middle receiving flask. Collect your “main body” fraction. You will see temps between 190-220C during this fraction. Continue to increase stirring speed as necessary. Reaction in the head may vary but it should never stop. As fluid level in the boiling flask decreases, increase stir speed. The final “tails” fraction is a mixture of the first and second fractions and should be saved for re-distillation later. Ideally, you want to turn the cow to the final flask before the tails fraction hits. The “tails” fraction has an obvious color change and will be darker than the “main body” fraction. You will see temps between 200-250C during this fraction. As fluid level in the boiling flask decreases even more, set stirring RPM higher (1000+ RPM). You may need to compensate with a bit more heat to finish of the final fraction as well. Once process is complete, stop heat, stop stir, and stop vacuum. Let atmosphere into the system. Be sure to properly store your distillate as exposure to air and light can cause oxidation. ***Note: This entire setup will ship via motor freight.*** ***Note: All units are inspected for broken glass or parts before unit is shipped. If unit arrives damaged or glass is broken (this does not include minor imperfections or scuffs in glassware), Customer MUST contact BVV™ within 3 days of delivery to file a claim and receive a replacement part. If customer DOES NOT contact BVV™ within 3 days of delivery responsibility for replacement parts falls on the customer and they must pay for replacement pieces.*** ***Glassware Safety Disclaimer: BVV™ is not responsible for failure of glassware which must be inspected before and after every use because it may eventually develop imperfections or damage through normal usage, mishandling, and stress caused by temperature variations. If an imperfection or damage is noted while inspecting the glassware DO NOT use the glassware because it can fail causing bodily harm or damage to the surrounding area.***
$10,500.00 - $14,750.00
Valved Vacuum Adapter - USA Made
Valved Vacuum Adapter This Valved Vacuum Adapter allows the user to isolate the vacuum in a short path distillation system from the cow or receiving flasks of the system to allow the easy swap of the flasks. This adapter has 24/40 Joints with the male joint having a grease-less Viton O-ring seal which reduces contamination and mess for each fraction. It also includes (2) 8mm GL-14 Hose Barb fittings with a PTFE threaded valve with Viton Seals. *Notice to customers: All units are inspected for broken glassware or parts before leaving BVV™. If the unit arrives damaged (this does not include minor imperfections or scuffs in glassware), the customer MUST contact BVV™ within 72 hours from carrier delivery to file a claim. If the customer DOES NOT contact BVV™ within 72 hours from carrier delivery, then BVV™ cannot issue any replacement(s) or compensation for the item; a new purchase will need to be made for a replacement. **Glassware Safety Disclaimer: BVV™ is not responsible for failure of glassware which must be inspected before and after every use because it may eventually develop imperfections or damage through normal usage, mishandling, and stress caused by temperature variations. If an imperfection or damage is noted while inspecting the glassware DO NOT use the glassware because it can fail causing bodily harm or damage to the surrounding area.**
$520.00
10L & 20L Injection Valve
10L & 20L Injection Valve *Notice to customers: All units are inspected for broken glassware or parts before leaving BVV™. If the unit arrives damaged (this does not include minor imperfections or scuffs in glassware), the customer MUST contact BVV™ within 72 hours from carrier delivery to file a claim. If the customer DOES NOT contact BVV™ within 72 hours from carrier delivery, then BVV™ cannot issue any replacement(s) or compensation for the item; a new purchase will need to be made for a replacement.
$45.00
Dk-Lok V63 Series 1/4" 10-250PSI Adjustable Pressure Relief Valve 316SS
V63 Series 1/4" 10-250PSI Adjustable Pressure Relief Valve 316SS DK-LOK® V63/66 series proportional relief valves provide a wide range of set pressures in order to protect your systems against over pressurization resulting in damage to system components. These proportional relief valves open in direct relation to how quickly the system inlet pressure overcomes the set pressure of the spring. They close in direct relation to how quickly the system inlet pressure drops below the spring set pressure. We offer a variety of connection configurations and seal materials to match your system requirements. DK-LOK V63/66 Series Pressure Relief Valve Data Sheet
$225.00
35/15 Metal Flask Clamp for 2L and 5L Eco Rotary Evaporators
35/15 Metal Flask Clamp for 2L and 5L Eco Rotary Evaporators This is a replacement clamp for 2L and 5L Eco Rotary Evaporator receiving flask.
$14.00
True Terpenes Cherry Pie
True Terpenes Cherry Pie Fragrance: Sweet Dank Earthy Sour Effects: Happy Creative Uplifting A hybrid of Durban Poison and Granddaddy Purple, this earthy berry blend is sweet and sour. Within minutes, it gives feelings of happiness, creativity and is uplifting. Storage Requirements: Keep in original container, lid securely tightened and away from heat, open flames, sunlight, combustible materials and hot surfaces. No Smoking. Store in a cool dry place. Improper storage can cause terpenes to degrade. Dilution: Terpene Strain & Flavor-Infused Strain Profiles, Effects-Based Terpene Profiles & Terpene Flavors:The Terpene products above must be diluted prior to use. (1-5% by total volume). Terpenes are oil soluble and mix well with plant extracts, coconut oil, and more. Viscosity Extract Modifier: The Terpene product above must be diluted prior to use. (1-3% by total volume). Terpenes are oil soluble and mix well with plant extracts, coconut oil, and more. Handle With Care: Can cause skin irritation, do not use PRIOR to dilution. Cherry Pie-Specific Certificates: Product Specification Certificate of Analysis Safety Data Sheet Food Safety Company-Specific Certificates: ISO 9001:2015 GMP Certification FSSC 22000
$121.50 - $2,250.00
Harvest Right PHARMACEUTICAL PRO Freeze Dryer - Medium
Harvest Right™ PHARMACEUTICAL PRO Freeze Dryer - Medium 7 TRAYS 6.5 sq ft tray space 4 LITERS OF ICE CAPACITY Key Features & Benefits - The freeze dryer has built in intelligence. It automatically and perfectly manages the freeze drying process - The ideal vacuum pressure and drying temperature is maintained for each material – preserves freshness and potency - 6.5 square feet of tray space - Shelving unit holds 7 trays (each tray 7.5″ W x 18″ L x 0.75″ H) - 4 liters of ice capacity - Weight: 127 lbs. Warranty 3 year limited warranty Dimensions Overall product dimensions: 18″ W x 21.25″ D x 28.5″ H Perfect for a counter top, cart or table. Power 110 volt outlet. Shipping Info - The medium freeze dryer ships in one package with a total weight of 216 lbs. - Item will be delivered to physical addresses, no PO boxes. - One freeze dryer package: 26″W x 36″D x 45″H. Maintenance Simply filter and replace oil. Takes one or two minutes. Industrial Grade Design High quality, super high vacuum High evacuation performance Light, fast, energy efficient Technical Specifications Oil: Harvest Right Oil, Robinair Premium High Vacuum Pump Oil or JB Industries Black Gold Vacuum Pump Oil Only DC Motor Energy Efficient Voltage: Standard, 115v, 60Hz Dimensions: 16.3″ x 6″ x 12.1″ Weight: 32 lbs Noise: 52 decibels Product ComparisonIndustrial Oil Pump vs Standard Oil Pump Oil ChangesThis new Industrial Pump rarely needs to have the oil changed or filtered. The pump has a gas ballast feature that makes it so water does not stay in the oil. Because of this, the oil in the pump will be pristine and clear, even after 30 or more batches. You simply won’t need to change the oil until you have run 25 to 40 batches. Whereas, the oil in the standard vacuum pump needs to be changed and filtered every 4 or 5 batches (when using the new 3/8 inch vacuum hose). Vacuum PressureUnder cold and hot conditions the Industrial Pump will pull a deeper vacuum than the Standard Pump. Under cold conditions the difference is .05 Pascal for the Industrial Pump and .08 Pascal for the Standard Pump. Whereas, under warm conditions the difference is much greater: .05 Pascal for the Industrial Pump and 2.05 Pascal for the Standard Pump.Hence, the Industrial Pump is especially not affected by warm, ambient conditions. When temperatures rise, it will pull a vacuum far better than the Standard Pump. The Industrial Pump is just not affected by outside heat. It pulls the same deep vacuum even when it is in a warm environment. NoiseThe Industrial Pump is substantially quieter than the Standard Pump, 52 decibels versus 64 decibels. The Industrial Pump at 52 decibels is about the same as a refrigerator. Oil Mist FilterBoth pumps come with an oil mist filter. However, the Industrial Pump’s oil mist filter allows for no oil spray at all and it will last much longer. Power UseThe Industrial Pump uses less power than the Standard Pump (187 watts versus 218 watts). AmperageUnder hot conditions at ultimate vacuum pressure the Standard Pump pulls 2.1 amps while the Industrial Pump only pulls 1.7 amps. Hence, the Industrial Pump is more efficient. WeightThe Industrial Pump is easier to move around as it weighs 5 pounds less than the Standard Pump (32 lbs. versus 37 lbs.) LifeThe Industrial Pump is more durable and will last longer than the Standard Pump.
$3,295.00 - $4,790.00
Hydrofarm - Trellis For Tents
This modular design trellis can be used in grow tents from 25" x 25" (2' x 2') to 60" x 60" (5' x 5') or 2' (60 cm) to 4' (120 cm). Made from soft elastic rubber netting, it has 36 six-inch square mesh openings that will gently yet firmly maintain your plants in proper upright position as they become heavy through the flowering process. It includes four hooks that will secure it to the support rods in your tent. Can also be used vertically. Modular design is ideal for grow tents 25" x 25" (2' x 2') to 60" x 60" (5' x 5') or 2' (60 cm) to 4' (120 cm) 36 mesh openings Soft elastic rubber net Can be used horizontally as well as vertically Durable and long-lasting Helps guide and support flowering plants Includes 4 hooks
$8.13$8.03
PRO-MIX HP Growing Medium with Mycorrhizae, 3.8 cu ft
******Minimum order quantity of 30 units****** PRO-MIX ® HP MYCORRHIZAE™ is a high porosity peat-based growing medium containing, beneficial mycorrhizal inoculum (Glomus intraradices). This formula ensures optimum growth, especially when high air capacity and extra drainage are required. It is ideal for water sensitive crops, rooting cutting and/or low-light growing conditions. Ingredients: Canadian Sphagnum peat moss (65-75% by volume) Perlite - horticultural grade Dolomitic and Calcitic limestone (pH adjuster) Wetting Agent Mycorrhizae - endomycorrhizal fungi (Glomus intraradices)
$75.95$70.04
Oasis 102-Cell Tray & Medium, case of 10
OASIS® WEDGE® growing media tapers in shape from top to bottom. This unique feature aids in directing root growth downward for rapid development, resulting in greater crop turnover and overall productivity for the grower. Each cell is singulated, thus no tangling of the fibrous root systems. Product comes preloaded with media in the tray and is immediately ready to use upon receipt. An improved, star-shaped dibble hole accommodates a variety of stem sizes making WEDGE® ideal for cloning most crops. Features:• Sterile medium• Ready-to-use right out of the box• Singulated cells; pre-assembled media in tray• Unique star-shaped hole accommodates most stem sizes for cloning• Patented WEDGE® shape encourages root growth downward Benefits:• Reduces disease and insect problems• Engineered for optimal cell-to-cell performance assuring proper drainage and water holding• Singulated cells prevent root tangling, eliminating plant shock at transplant• Low cation exchange capacity for rapid nutrient availability One case includes 10 pre-filled trays
$107.67
FoxFarm - Dirty Dozen Starter Kit
DUE TO SHIPPING RESTRICTIONS WE ARE UNABLE TO SEND PRODUCT TO THESE FOLLOWING STATES - HAWAII, ILLINOIS, MINNESOTA, PUERTO RICO, SOUTH DAKOTA AND WISCONSIN The Dirty Dozen® is a force to be reckoned with! Twelve of these fiercest warriors will get your garden into the spotlight. The Dirty Dozen® Starter Pack contains 9 PT liquids: Kangaroots®, Microbe Brew®, Bembé®, Sledgehammer®, Flowers Kiss®, Boomerang®, Big Bloom®, Tiger Bloom®, & Grow Big® and three 6-Ounce solubles: Open Sesame®, Beastie Bloomz®, & Cha Ching®.
$151.95$138.55
Jacketed Sucker Pot with Ring Stand
Jacketed Sucker Pot with Ring Stand This jacketed sucker pot works perfectly as a collection base for extracted oil and easy discharge or as a storage vessel for distillate dispensing. Both of these applications are made easier with the use of a heater running through the jacket. Connections: -Top: 6" Tri-Clamp -Bottom: 1/4" FNPT -Jacket: 1/4" FNPT (2x ports)
$600.00
1/2" Fractional Tube Fitting Hose
1/2" Fractional Tube Fitting Hose These chemically resistant PTFE braided hoses are a necessity when dealing with harsh chemicals or solvents and high-pressure applications. They provide a uniquely rugged, durable, and chemically resistant combination of Stainless Steel and PTFE by having an inner core of PTFE and protecting that with a braided stainless steel outer sleeve. These hoses have a tube stub on each end that fits a standard compression fitting. ***Note: Do not exceed the specified hose bend radius or the inner PTFE liner will kink and the hose integrity will become compromised and should not be used. Specifications: Connection Type(s): 1/2" Tube Stub Liner Material PTFE (Teflon) Braid Material 304 Stainless Steel Swivel Material 304 Stainless Steel Temperature Rating -94°F to 500°F (-70°C - 260°C) Pressure Rating 1500 PSI Chemical Resistance Excellent Max Bend Radius 5 1/2"
$47.50 - $88.00
Hydrochloric Acid 37% ACS Reagent Grade (HCL)
Hydrochloric Acid 37% ACS Reagent Grade HCL pH: 1.1 Hydrochloric acid, solution is a colorless watery liquid with a sharp, irritating odor. Consists of hydrogen chloride, a gas, dissolved in water. Sinks and mixes with water. HCL vapors are heavier than air. It is classified as a Strong Acid and is used in many types of laboratory preparations. Chemical Formula: HCl Molecular Weight: 36.46 CAS Registry Number: 7647-01-0 Appearance Colorless, transparent liquid, fumes in air if concentrated Odor: Pungent characteristic Density 0.81 g/cm3 Boiling Point: 61C @ 36% Concentration GHS Pictograms: GHS Signal Word: Danger GHS Hazard Statements: H290, H314, H335 GHS Precautionary Statements P210, P233, P240, P305+P351+P338, P403+P23 P260, P280, P303+P361+P353, P305+P351+P338 UN Identification Number: 1789 Proper Shipping Name: Hydrochloric acid solution Transport Hazard Class: 8 Packing Group: II DOT Placard: What Is Hydrochloric Acid? Hydrochloric acid (HCl) is a strong, highly corrosive acid that is widely used in various industrial, commercial, and laboratory applications. It is a solution of hydrogen chloride gas dissolved in water, forming a clear, colorless liquid with a sharp, pungent odor. Chemically, hydrochloric acid is composed of hydrogen (H) and chlorine (Cl) atoms, with a chemical formula of HCl. In aqueous solution, hydrochloric acid dissociates into hydrogen ions (H⁺) and chloride ions (Cl⁻), making it a strong acid. How Is Hydrochloric Acid Produced? Hydrochloric acid (HCl) is typically produced on an industrial scale through the chemical reaction between hydrogen gas (H2) and chlorine gas (Cl2). This reaction is exothermic and requires the presence of a suitable catalyst to proceed efficiently. The primary method for producing hydrochloric acid involves the following steps: Preparation of Hydrogen: Hydrogen gas (H2) is produced through various methods, such as steam reforming of natural gas (methane), electrolysis of water, or as a byproduct of certain chemical processes. Steam reforming is the most common method for large-scale hydrogen production, where methane is reacted with steam in the presence of a nickel-based catalyst to produce hydrogen gas and carbon monoxide: CH4 + H2O → CO + 3H2 The produced hydrogen gas is then purified to remove impurities before use in the hydrochloric acid production process. Preparation of Chlorine: Chlorine gas (Cl2) is typically produced by the electrolysis of sodium chloride (table salt) solution, known as the chlor-alkali process. In this process, an electric current is passed through a brine solution (sodium chloride dissolved in water), resulting in the decomposition of water and the formation of chlorine gas at the anode: 2Cl⁻ → Cl2 + 2e⁻ The chlorine gas is then purified and dried to remove any water vapor before use in the hydrochloric acid production process. Hydrogen-Chlorine Reaction: Once hydrogen and chlorine gases are prepared, they are combined and reacted in a controlled manner. The reaction typically occurs in a reactor vessel equipped with a suitable catalyst, such as platinum or rhodium, to facilitate the reaction: H2 + Cl2 → 2HCl This reaction produces hydrochloric acid gas (HCl), which is then cooled and condensed to form a liquid solution of hydrochloric acid. Dissolution in Water: The hydrochloric acid gas is dissolved in water to produce a concentrated solution of hydrochloric acid. This solution can be further diluted to the desired concentration for various industrial, commercial, or laboratory applications. Overall, the production of hydrochloric acid involves the controlled reaction of hydrogen and chlorine gases in the presence of a catalyst, followed by the dissolution of the resulting hydrochloric acid gas in water. The process is typically carried out in specialized chemical plants equipped with the necessary infrastructure and safety measures to handle corrosive and hazardous materials. What Is Hydrochloric Acid Used for? Hydrochloric acid (HCl) is a versatile and widely used chemical with numerous industrial, commercial, and laboratory applications. Some common uses of hydrochloric acid include: Chemical Manufacturing: Hydrochloric acid is used in the production of a wide range of chemicals, including chlorine, vinyl chloride (used to make PVC), and various pharmaceuticals, dyes, and pigments. Steel Pickling: Hydrochloric acid is commonly used for pickling or cleaning steel surfaces to remove rust, scale, and other impurities before further processing, such as galvanizing or coating. pH Control: Hydrochloric acid is used as a pH adjuster or neutralizer in various industrial processes, wastewater treatment, and swimming pool maintenance. Food Processing: Hydrochloric acid is used in the food industry for various purposes, including adjusting acidity, flavor enhancement, and food preservation (in accordance with regulatory guidelines). Laboratory Applications: Hydrochloric acid is commonly used in laboratories for chemical analysis, titrations, and as a reagent in various chemical reactions. Household Cleaning Products: Dilute hydrochloric acid solutions are used in household cleaning products, such as toilet bowl cleaners and descaling agents. Oil and Gas Production: Hydrochloric acid is used in the oil and gas industry for various applications, including well acidization to enhance the productivity of oil and gas wells. Water Treatment: Hydrochloric acid is used in water treatment processes to control pH, remove mineral scale deposits, and neutralize alkaline substances. Textile and Leather Processing: Hydrochloric acid is used in textile and leather processing industries for desizing, bleaching, and pH adjustment. Metal Cleaning and Etching: Hydrochloric acid is used for cleaning and etching metals, such as aluminum, copper, and brass, in various manufacturing processes. Chemical Synthesis: Hydrochloric acid is used as a reactant or catalyst in various chemical synthesis processes, including the production of pharmaceuticals, plastics, and synthetic rubber. These are just a few examples of the diverse range of applications for hydrochloric acid. Its versatility, corrosive properties, and ability to adjust pH make it an essential chemical in many industries and processes. However, it's important to handle hydrochloric acid with care due to its corrosive nature and potential health hazards. Proper safety precautions, such as wearing protective equipment and following appropriate handling and storage procedures, should be observed when working with hydrochloric acid. What Are The Hazards of Hydrochloric Acid? Hydrochloric acid (HCl) is a highly corrosive and hazardous chemical that can pose several risks to human health, safety, and the environment. Some of the main hazards associated with hydrochloric acid include: Corrosive Properties: Hydrochloric acid is highly corrosive to skin, eyes, respiratory tract, and mucous membranes. Contact with concentrated hydrochloric acid can cause severe chemical burns, irritation, and tissue damage. Inhalation of hydrochloric acid vapors or mists can also cause irritation and damage to the respiratory system. Acute Toxicity: Exposure to high concentrations of hydrochloric acid vapor or mist can cause acute toxicity, leading to symptoms such as coughing, difficulty breathing, chest pain, and throat irritation. Severe exposure may result in pulmonary edema (fluid buildup in the lungs) and respiratory distress. Environmental Hazards: Spills or releases of hydrochloric acid can have adverse effects on the environment, including contamination of soil, water bodies, and aquatic ecosystems. Hydrochloric acid can be corrosive to metals and may cause damage to infrastructure and equipment if not properly contained and managed. Reactivity: Hydrochloric acid is reactive with a wide range of substances, including metals, alkalis, and organic materials. It can release hazardous gases (such as hydrogen gas) when reacting with certain metals, posing fire and explosion hazards in confined spaces. Storage and Handling Risks: Hydrochloric acid must be stored and handled with care due to its corrosive and reactive nature. Improper storage, handling, or mixing with incompatible substances can lead to accidents, spills, and exposure incidents. Health Effects: Prolonged or repeated exposure to hydrochloric acid vapor or mist may cause chronic respiratory effects, such as bronchitis, asthma, or chronic obstructive pulmonary disease (COPD). Individuals with pre-existing respiratory conditions or sensitivities may be more susceptible to the effects of hydrochloric acid exposure. Skin and Eye Damage: Contact with hydrochloric acid can cause severe chemical burns and damage to the skin and eyes. Eye contact may result in irritation, redness, and blurred vision, while skin contact may cause pain, redness, and blistering. Ingestion Hazards: Ingestion of hydrochloric acid can cause severe burns to the mouth, throat, esophagus, and stomach, leading to tissue damage, perforation, and internal bleeding. Ingestion of even small amounts of concentrated hydrochloric acid can be life-threatening and requires immediate medical attention. Overall, the hazards associated with hydrochloric acid underscore the importance of proper handling, storage, and use of this chemical in industrial, commercial, and laboratory settings. Employers and workers should be trained on the safe handling procedures, use of personal protective equipment, and emergency response protocols to minimize the risks associated with hydrochloric acid exposure. Additionally, regulatory guidelines and safety standards should be followed to ensure compliance and protect human health and the environment. Hydrochloric Acid SDS
$25.00 - $1,450.00
Cannabis QTest
Cannabis QTest Know Your Dose with the Cannabis QTest The Cannabis QTest is a single-use cannabis test kit that can quickly and easily tell you the percentage of THC and CBD in cannabis flower or buds. You can test as much cannabis as you like, but you need to finely chop and mix it first (or grind it up in a coffee grinder). After you homogenize your material this way, the result of your test will then apply to the all rest of your cannabis. Simply follow the instructions and compare the color of the detection vial to the enclosed color chart. It’s that simple. Instructions Note: A paper version of these instructions comes with your order. IMPORTANT INFORMATION! – READ THIS FIRST • Use this kit at room temperature. (If stored in a refrigerator, let it warm up for one hour first.)• Perform the test on a flat surface during the daytime.• Evaluate the result in daylight immediately after the 10-minute development time. (The color can change if you wait too long.)• Use a white, letter-sized sheet of paper as a background when evaluating the color. (See section four for evaluation details.)• Read all the instructions at least once through before beginning the test. 1. IMPORTANT BACKGROUND INFORMATION This test kit can be used to detect the concentration of active ingredients THC and CBD in cannabis flower. The kit will not work with concentrated extracts, gummies, chocolates, brownies or other edibles. 2. PREPARING FOR THE TEST Take out all the items from your kit. Along with these instructions, you should have: • protective gloves• plastic dropper bottle with green cap (for determining CBD concentration)• glass vial with red lid containing dry crystals (for determining THC concentration)• plastic blister with twist-and-tear-off tip containing developer solution You will also need a milligram scale and either a small funnel or a creased piece of paper to carefully pour the flower material into the plastic extraction bottle. (You can make your own paper funnel. Google it!) Note: If you are testing cannabis flower (buds), you need to homogenize the material before you perform the test. A coffee grinder works best. If you do not have a coffee grinder then you can chop your material finely on a cutting board using a sharp knife. Then mix the chopped material thoroughly. You will be using 20 milligrams (mg) of material for the test. The result will tell you the percentage of THC and CBD in all the remaining cannabis that you honogenized. 3. PERFORMING THE TEST 3.1 First put on the enclosed nitrile gloves and wear appropriate protective clothing and safety glasses. If you wear contact lenses, remove them. The ingredients contain acids which may cause skin irritation or severe eye damage. In the event you come in contact with the ingredients (liquid or dry), remove the affected clothing immediately and rinse the affected skin area with water for several minutes. In case of eye contact, rinse the affected eye with running water for several minutes. (Keep pets, especially cats, away from the testing area.) 3.2 Carefully weigh 20 mg (0.20 g) of your homogenized cannabis using a milligram scale. 3.3 To determine the concentration of CBD in your sample, open the plastic dropper bottle with the green cap (by turning the white part of the cap). Carefully pour the 20 mg of homogenized cannabis flower (or the proportionally lesser amount of concentrated extract) into the bottle using a funnel or a creased piece of paper, then put the lid back on and close it tightly. Next, shake the bottle well for about 12 to 20 seconds, then set it down to rest for 10 minutes. During the resting period, repeat the shaking process two more times; once at about the 3-minute mark, and again at about the 7-minute mark. Each time you set the bottle down to rest, make sure the cannabis material remains inside the liquid. (If you see material stuck in the upper section of the bottle, one or two quick shakes with the bottle in a vertical position will usually rinse it all back down.) After 10 minutes, evaluate the results immediately. If CBD is present, the detection liquid will be a shade of purple. Use the left side of the enclosed color chart to determine the CBD content. For details, see section 4 below, “EVALUATING THE RESULT.” Then come back to this section to perform the THC part of the test. IMPORTANT! – Evaluate the CBD content immediately after the 10-minute mark. You have about three minutes. The liquid will continue to change color after this time and falsify the result. 3.4 To determine the concentration of THC in your sample, open the small glass vial with the red lid. Then remove the green cap from the plastic dropper bottle you just used (not the white part this time, just the green tip) and add 10 drops to the vial. Next you are going to twist and tear off the top of the plastic blister (to open it) and add 5 drops of the liquid into the vial also. IMPORTANT – Before you open the blister, make sure the liquid inside is congregated at the bottom. Otherwise it can spill out when you tear it open. If you see liquid near the top (near the tear point), just shake it a little or tap it on a table so the liquid drops down to the bottom. Then it is safe to twist and tear off the top. After adding five drops of liquid from the blister, put the red lid back on the glass vial and close it tightly, then gently move the vial from side to side to mix the ingredients. 3.5 The liquid in the glass vial will change color almost immediately (within 10 seconds). Use the right side of the enclosed color chart to determine the THC content of your material. See section 4 below for details. 4. EVALUATING THE RESULT Follow the instructions above before evaluating the result. EVALUATING THE CBD CONTENT (THE PLASTIC BOTTLE WITH THE GREEN LID) The detection reagent in the plastic dropper bottle will not change color in the presence of THC, but only in the presence of CBD. Use the left side of the color chart and the “SPECIFIC EVALUATION INSTRUCTIONS” below to determine the concentration. EVALUATING THE THC CONTENT (THE SMALL GLASS VIAL WITH THE RED LID) If there is THC in the material, the liquid in the small vial will turn purple. Use the right side of the color chart and the “SPECIFIC EVALUATION INSTRUCTIONS” below to determine the concentration. If there is no THC but there is CBD, the liquid in the small vial will turn orange. If there is neither THC nor CBD, the liquid in the small vial won’t change color (or will turn slightly gray). SPECIFIC EVALUATION INSTRUCTIONS By comparing the intensity or saturation of the liquid in the vial with the enclosed color chart, you can determine the result visually. Daytime sunlight is best suited for optimal evaluation. If using artificial light, the influence of different color temperatures may slightly change the hue. You can still perform the evaluation, but you should take this into account (e.g. high blue content in energy-saving lamps, green discoloration when using LED light from cell phones, etc). • Use a white, letter-sized sheet of paper as a background.• In daylight or under bright light, hold the glass vial next to the color chart about six to eight inches in front of the white sheet of paper and look through the glass vial head on. For best results, your eyes should be fairly close to the vial, but no closer than about six to eight inches.• Now compare the color of the liquid in the vial to the color chart. The corresponding concentration of THC and CBD is listed as a percentage. • This concentration applies to your remaining homogenized cannabis. • Do not evaluate the liquid after four hours. At this time the color may no longer be reliable. 5. STORAGE AND SHELF LIFE Store the reagents in the refrigerator (35° – 46° F) and out of direct sunlight for a shelf life of at least 18 months. 6. WARNINGS • Keep the kit away from children and animals.• When performing the test, wear suitable protective gloves, clothing and face/eye protection. If you wear contact lenses, remove them before using the test kit.• The liquids contained in the test kit consist of various acids which may cause a corrosive/irritating effect on the skin or severe eye damage/irritation. Avoid contact with the skin, eyes, mouth or clothing.• Should contact with the above listed areas occur, remove the relevant clothing immediately. Instantly rinse the affected skin areas with water for several minutes. In case of contact with the eyes, immediately rinse them with water for several minutes using both hands to keep the upper and lower eyelids open.• Substances processed with the test kit are not to be consumed! 7. DISCLAIMERS • QTests are only to be used for the detection and quantification of unknown substances.• The result may not be 100% accurate. Your sample could be adulterated with one or more unknown substances that cross-react with the reagents, affecting the quantitative result.• The result does not mean your sample is safe to consume. It could still contain unwanted substances and impurities that can be harmful or even deadly.• The Cannabis QTest is not a substitute for laboratory analysis.• miraculix and/or Qtests.org assume no responsibility for the use or misuse of the test kit or the results. 7. DISPOSAL OF MATERIALS Check your local regulations for proper disposal of acids.
$24.95
32 Gallon All-Mesh Bubble Wash Bags
32 Gallon All-Mesh Bubble Wash Bags The Press Club Wash Bags are the last set of bubble wash bags you'll ever own! Made from premium, food-grade material specifically for washing you can stop second guessing whether you have the right or best bags in the industry. All The Press Club bubble wash bags are hand sewn with our proprietary pink stitching, making them 2x stronger than competitors. You can be confident their bags will perform the same no matter if it's your 1st or 1000th wash. The Press Club Is so confident that their bubble wash bags will stand the test of time, every bag comes with a Lifetime Warranty. If you have any manufacturer issues, they will be more than happy to replace the bag for you! KEY FEATURES Fits All Standard 32 Gallon Buckets Hand Sewn With Our Proprietary Pink Stitch w/ Food-Grade Materials Military-Grade Waterproof & No Flaking Bag Liner Premium Drawstring & Cord Locks To Secure Bags Lifetime Warranty On All Wash Bags Includes Meshed Carrying Case For 2-Way Drying & Storage Made In USA AVAILABLE MICRONS 220 Micron (Work Bag), 190 Micron, 160 Micron, 120 Micron, 90 Micron, 73 Micron, 45 Micron, 25 Micron
$59.95
BVV™ Terpenes WIFI
BVV™ Terpenes WIFI All sales are final. Orders can be refunded prior to fulfillment and shipping but once the order has been fulfilled and/or shipped, no refunds will be issued. Due to the hazardous nature of our product, we are unable to accept returns. BVV™ Terpenes are botanically derived terpenes enhanced with "nature-identical" artificial flavors. These flavors boost the natural flavor profile of the terpenes, providing the user with a more pleasant vaping experience. In order to provide complete transparency and elicit customer confidence, all ingredients are disclosed in the technical data sheet. BVV WIFI Safety Data Sheet BVV WIFI Technical Data Sheet WIFI: The aroma is earthy, pungent, and sweet. White Fire (Wifi) is great for increasing focus, creativity, happiness, and peacefulness. Euphoric and uplifting blend. FRAGRANCE: Pungent, earthy, sweet, sour EFFECT: Uplifted, focused, energetic, soothing Storage Requirements: Keep in the original container, lid securely tightened and away from heat, open flames, sunlight, combustible materials, and hot surfaces. Store below 15℃ (60℉). Improper storage can cause terpenes to degrade. Dilution: Terpenes must be diluted prior to use for flavor and effect (1-5% by total volume). Terpenes are oil soluble and mix well with plant extracts, coconut oil, and more. Handle With Care: Can cause skin irritation, do not ingest PRIOR to dilution.
$10.00 - $150.00
Stainless Steel Laboratory Scissor Jacks
Stainless Steel Scissor Jacks Adjustable height laboratory scissor jack. The platform is 4"/6"/8" & the durable 304 stainless steel heavy-duty lab lifts with very little effort necessary! Specifications: 304 Stainless Steel Platform size: 4" x 4" / 6" x 6" / 8" x 8"
$29.00 - $49.00
2L Electric Receiving Flask with PTFE Valve
2L Electric Receiving Flask with PTFE Valve This receiving flask fits Best Value Vacs 2L Electric Rotary Evaporators and is made out of GG-17 glass with a PTFE dispensing valve. This Flask has a 35/15 round joint with a 1/2" Hose Barb and Viton gaskets on the Teflon Valve.
$150.00
KF-40 Stainless Steel FNPT End Cap
KF-40 Stainless Steel FNPT End Cap This is a FNPT KF-40 (NW40) Endcap to adapt a KF40 fitting to Female NPT Threads for 1/4", 3/8", and 1/2" NPT.
$34.00 - $39.00
Huber SilOil M60.115/200.05, Heat transfer fluid -60 to 200 °C
Huber SilOil M60.115/200.05, Heat transfer fluid -60 to 200 °C SilOil M60.115/200.05 is a low-viscosity silicone fluid which, as a result of its special property profile, is particularly suitable for use as a cold and heat transfer medium in cryostats, thermostats and heat transfer installations. SilOil M60.115/200.05 can be used in the range from -60 °C to 115 °C (for open systems) and to 200 °C in externally sealed systems (Unistats). It should be borne in mind that, at high temperatures, SilOil M60.115/200.05 can be chemically altered by oxidising media, such as air, or substances with a catalytic effect, such as acids, lyes and various metal compounds. An increase in viscosity, and possibly even gelling of the fluid owing to crosslinking reactions, must be expected in the presence of oxidising agents, while contact with products having a catalytic effect usually induces a process of depolymerisation, resulting in a drop in viscosity Advantages: virtually insolubile in water non-corrosive low setting points and vapour pressures high flash points low toxicit odourless no coking tendency under thermal stress high thermal stability resistance to ageing chlorine free Safety Data Sheet Heat transfer fluid M60.115/200.05 Working temperature °C 60 to 115/200 open/closed systems: -60°C…115°C Unistats (only closed): -60°C…200°C Material: silicon oil Viscosity at 25°C: 5 mm²/s Colour colourless, clear Material incompatibility Silicone rubber
$870.00 - $1,560.00
5 Gallon Aluminum SIDEMOUNT - POT ONLY
5 Gallon Aluminum SIDEMOUNT - POT ONLY ***Note: 'with Hardware' Option only includes the side-mount manifold with gauge pre-installed. (Does Not Include Lid or Gasket) This is a replacement part for the following Vacuum Chambers: Best Value Vacs 5 Gallon Aluminum Side Mount Vacuum and Degassing Chamber Glass Vac 5 Gallon Aluminum Vacuum Chamber Dimensions: 10" Tall x 12" Diameter Hole Size: 21/64 Material: 3004 Aluminum
$48.00 - $60.00
Union Cross
SSP - Union Cross SSP Instrumentation Duolok® tube fittings are designed, manufactured and quality controlled to be totally “interchangeable” with the Swagelok® brand of tube fittings. Component by component examination plainly shows the two brands as completely “componentintermixable.” The precision manufacturing of both products to stringent tolerances under rigid quality control procedures ensures the safety, performance, and reliability of service whenever Duolok® and Swagelok® component parts are mixed and used in accordance with published installation and service recommendations. Specifications Connection Type 1 Duolok Tube Fitting Connection Size 1 Specified by User Material 316 Stainless Steel ASTM A-276 and A-479 bar stock, A-182 forgings. Duolok Pressure Rating = Tubing Rating SSP proudly makes Duolok®, TruFit®, FloLok® and hundreds of other products 100% in the USA!
$29.00 - $35.00
3 Way Ball Valve - Fractional Tube Fitting
SSP - 3 Way Ball Valve - Fractional Tube Fitting SSP Instrumentation Flolok® manually operated three-way ball valves accept media through the bottom port and allow selection of flow through a selected port. Features: Directional handle indicates flow direction Panel Mountable 180-degree actuation Directional flow path Micro-finished ball provides positive seal Free-floating ball design provides compensation for seat wear for repetitive sealing Blow-out proof ball & stem Standard Product Testing - Every ball valve is assembled and tested @ 1000 psi (68.9 bar) with Nitrogen Specifications Body Material 316 Stainless Steel Pressure Rating @ 100F 3000 PSIG @37C 208 BAR @300F 2500 PSIG @148C 172 BAR Connection Type 1 Duolok Tube Fitting Connection Size 1 Specified by User Connection Type 2 Duolok Tube Fitting Connection Size 2 Specified by User Connection Type 3 Duolok Tube Fitting Connection Size 3 Specified by User Handle Type Nylon-Stainless Steel Insert Handle Color Black Packing Material PTFE SSP proudly makes Duolok®, TruFit®, FloLok® and hundreds of other products 100% in the USA!
$150.00 - $230.00
3.2CF BVV™ Neocision Lab Certified Vacuum Oven and V9D 9CFM Two Stage Vacuum Pump Kit
3.2CF BVV™ Neocision Lab Certified Vacuum Oven and V9D 9CFM Two Stage Vacuum Pump Kit Disclaimer: This unit is intended for LEGAL purposes only, to be used in accordance with local laws and ordinances. Use only in well-ventilated areas! INTRODUCTION Our vacuum ovens are purpose-built to perform degassing / purging of light hydrocarbon solvents. Using the technique of cold boiling, the oven applies a gentle heat under reduced pressure conditions to expedite solvent degassing while simultaneously preserving color, aroma, and overall solute quality. We've applied our extensive vacuum expertise and industry experience to produce a series of ovens designed exactly for your needs: low consumption, high-throughput, and reliable operation. PERFORMANCE CAPABILITIES At Best Value Vacs, we make every effort to provide oven performance capabilities in a standardized format. We're not interested in juking our stats to make a sale. Instead, our goal is to provide quality, transparent production capabilities that meet the demands of our professional customers. Temperature Stability: ±1.0° Temperature Uniformity: within 4% of the temperature set point. Heat-Up Time: 20 minutes. Ultimate Vacuum: <500 µmHg / mTorr / micron Time to Vacuum: 5 minutes to 29"Hg. Vacuum Hold: guaranteed to lose less than 1"Hg (25.4 torr) in 24 hours. SPECIFICATIONS Electrical Voltage 120V Frequency 60HZ Power 1050W Current 16A Plug IEC C13 (unit ships with detachable NEMA 5-15p cable) Internal Chamber Heating Individual Direct-Heat shelves Temperature Range RT+18°-212°F Chamber Material Stainless Stee Dimensions (LxWxH) 17.7" x 17.7" x 17.7" (450mm x 450mm x 450mm) Vacuum Gauge Style Glycerin-filled for accuracy and longevity Range (units) -30 to 0 (inHg) / -1 to 0 (bar) Shelving Ships With 4 Heated Shelves Shelf Dimensions (LxW) 17" x 17.25" Shelf Capacity 293 in2 Total Shelf Capacity 1173 in2 / 8.2 ft2 Door Seal Silicone on Tempered Glass Window Dimensions (LxH) 15.5" x 16.25" Lights 4 strips of LEDs provide clear, bright view of interior Handle Aluminum Exterior Dimensions (LxWxH) 30" x 27" x 27" Weight 260 lbs Support Locking Casters Safety Electrical Built-in, resettable, overcurrent circuit breaker Thermal Automatic overtemperature shutoff Compliance CE CE Listing Recognized ISO ISO 9001:2015 ETL Certified Conforms to ANSI/UL STD.61010-1, 61010-2-010 -- Certified to CAN/CSA STD. C22.2 NO.61010-1, 61010-2-010 Connection Vacuum Inlet KF25 / NW25, quarter-turn valve Purge Inlet 5/16" Barbed, 10-turn valve Atmospheric Release Quick-release dial Contains Ships With KF25 x 1/4" JIC Flare with 1/4" vacuum hose and adjusting wrenches. User Manual Included Warranty 3 year oven warranty Vacuum Pump BVV™ V9D 9CFM Two Stage Vacuum Pump CAPACITY AND THROUGHPUT PLANNING Oven capacity requirements vary widely by the producer. We wanted to create a method to assist in determining the best oven match for your operation, based on a few of the parameters of your extraction and of your desired purge. We based this formula on an expected extraction yield of 25%, with an extract-density of 1 g/in2. Using the following variables, this formula is designed to provide an estimate of your required shelving capacity: Size = Extraction Batch Size (lbs) Number = Runs per 24h Period Purge = Your desired purging duration (hours) Area Required (ft2) = [(Size) * (Number) * (Purge+1)] / 122Area Required (in2) = (Size) * (Number) * (Purge+1) * 1.18
$4,630.00
BVV™ Stackable Diamond Miner V2
BVV™ Stackable Diamond Miner V2 The Stackable Diamond Miner V2 Diamond miner eliminates the need for glass jars and adds safety to your degassing procedure. Allowing you to see your Diamond growth through the top sight glass and by pulling up the Stackable Diamond Miner Tray once the process is completed. This diamond miner comes rack-mounted with a fully jacketed column and high-pressure clamps.
$2,250.00
Neocision Spectra Explorer LED Grow Light
Neocision Spectra Explorer LED Grow Light Explorer Our Explorer grow light fixture is designed for a full grow cycle with maximized red for increased photosynthesis. Ideal for 2’ x 4’ tent environments for increased consistency and yield. Neocision Spectra Explorer Cutsheet Performance, Specs, Ranking FEATURES: Efficacy up to 2.56 Micromoles / J @120 VAC Industry Leading Horticulture LEDs RJ Port for Plug and Play Control Systems Fast and Easy Installation 7 Year Limited Warranty on Fixture 8 Year Limited Warranty on Driver Looking for bulk purchases? We offer volume discounts and other value adding services with our partners at RSX Enterprises. Call (331-281-0154) and speak with a rep for more information. SPECTRUM AND EFFICACY PPF Efficacy: 2.56 at 120VAC Photon Flux (µmol/s) (400-700nm): 870 Photon Flux Blue (µmol/s) (400-500nm): 161 Photon Flux Green (µmol/s) (500-600nm): 355 Photon Flux Red (µmol/s) (600-700nm): 355 Total Blue/Red - Energy Bands: 516 % Blue: 18.51% % Green: 40.76% % Red: 40.73% POWER Power Consumption: 340W AC Driver: Sosen Power Factor: >0.95 Surge Protection: 6 KV 120V: 2.90 A 208V: 1.75 A 240V: 1.51 A 277V: 1.31 A DIMENSIONS Fixture Size (driver mounted on the fixture): (L) 43.7” x (W) 22” x (H) 4.1” Fixture Size (without driver): (L) 43.7” x (W) 22” x (H) 1.6” Power Supply Dimension: (L)18.7” X (W) 4.4” X (H) 2.4” Driver Net Weight: 6 lb. Fixture Net Weight: 6 lb. OTHER Mounting Height >6” above canopy Beam Angle 120 Degree Input Voltage 100 - 277 VAC Manual Dimming Knob Yes Built In Control Ports Yes Standard Power Cord (Extensions available) AWG 18, 6 Foot Standard Plug 120 VAC - NEMA 5-15P Substitute Plugs (Upon request at order for bulk purchases) 240 VAC, 277 VAC, Pigtails Adjustable Height Hanging Kit Included Yes Fixture Warranty 7 Years Limited Driver Warranty 8 Years Limited ETL Safety Certified Conforms to UL 1598:2018 Ed.4Certified to CSA C22.2#250.0:2018 Ed.4*ETL Safety Certified No. 5020070
$499.00$449.00
Neocision Spectra Veg LED Grow Light - DLC Listed
Neocision Spectra Veg LED Grow Light VEGETATIVE Our Vegetative Spectrum 5000k grow light fixture is designed to produce a healthy and more flavorful, aromatic yield. Experience a new level of cultivation. Neocision Spectra Veg Cutsheet DLC Qualified Product List Performance, Specs, Ranking FEATURES: Efficacy up to 2.51 Micromoles / J @120 VAC Industry Leading Horticulture LEDs RJ Port for Plug and Play Control Systems Fast and Easy Installation 7 Year Limited Warranty on Fixture 8 Year Limited Warranty on Driver Looking for bulk purchases? We offer volume discounts and other value-adding services with our partners at RSX Enterprises. Call (331-281-0154) and speak with a rep for more information. SPECTRUM AND EFFICACY PPF Efficacy: 2.5~2.60 at 120VAC - 240VAC Photon Flux (µmol/s) (400-700nm): 853 Photon Flux Blue (µmol/s) (400-500nm): 221 Photon Flux Green (µmol/s) (500-600nm): 390 Photon Flux Red (µmol/s) (600-700nm): 242 Total Blue/Red - Energy Bands: 463 % Blue: 25.94% % Green: 45.70% % Red: 28.53% POWER Power Consumption: 340W AC Driver: Sosen Power Factor: >0.95 Surge Protection: 6 KV 120V: 2.90 A 208V: 1.75 A 240V: 1.51 A 277V: 1.31 A DIMENSIONS Fixture Size (driver mounted on the fixture): (L) 43.9” x (W) 22” x (H) 4.1” Fixture Size (without driver): (L) 43.9” x (W) 22” x (H) 1.6” Power Supply Dimension: (L)16.9” X (W) 6.5” X (H) 3” Driver Net Weight: 6 lb. Fixture Net Weight: 6 lb. OTHER Mounting Height >6” above canopy Beam Angle 110 Degree Input Voltage 100 - 277 VAC Manual Dimming Knob Yes Built In Control Ports Yes Standard Power Cord (Extensions available) AWG 18, 6 Foot Standard Plug 240 VAC - NEMA 6-15P Substitute Plugs (Upon request at order) 120 VAC, 277 VAC, Pigtails Adjustable Height Hanging Kit Included Yes Fixture Warranty 7 Years Limited Driver Warranty 8 Years Limited ETL Safety Certified Conforms to UL 1598:2018 Ed.4Certified to CSA C22.2#250.0:2018 Ed.4*ETL Safety Certified No. 5020070 DLC Listed Yes
$449.00$404.00
GEOLITE - Clay Pebbles
GEOLITE clay pebbles serve as a strong, durable and versatile media, perfect for hydroponics and many horticultural applications. Made from 100% natural Italian clay, this media is industrially produced at extremely high temperatures (2200°F/1200°C) and specially treated for a consistent EC and stable, neutral pH. It offers great aeration and drainage, ensuring success with technically one of the best growing medias for your indoor garden. Thanks to GEOLITE clay pebbles' unique structure and ability to cover a large surface area, they offer the ideal environment to foster beneficial bacterial growth around the root zone. Ideal for drip feed, deep water culture, and flood and drain systems. 45 L bag. pH-neutral and chemically inert Stable and low-EC High total porosity (approximately 85% by volume) provides excellent root ventilation and oxygenation to plants Excellent draining capacity Strong, stable and durable Great for soil aeration and drainage Perfect for hydroponics, hydroculture, and aquaponics 8-20 mm size
$19.95$18.78
Eco Oven PID Controller with Display Screen
Eco Oven PID Controller with Display Screen Compatible with older Orange/Black Models and newer Purple/White Models. Specifications BVV ECO Temp Range: 0-212°F Temp Accuracy: +/- 1° Built-In Calibration: Yes Temp Display Unit: C or F Timer Range: 0-999 Electrical Requirements: 110v @ 60Hz Compatible Ovens: 09ECO / 19ECO Shipping Dimensions: 5 x 5 x 5 - 1lbs SKU: ECOPID
$150.00
Nitrogen Hydrogen 95% N2 and 5% H
Nitrogen Hydrogen 95% N2 and 5% H 99.5% Purity, Filled, Compressed Gas Made in Italy This 3"x12" compressed gas tank is filled with a high purity blend of nitrogen and hydrogen. 95% Nitrogen and 5% Hydrogen. The gas can be removed using our regulator or valve dispenser that attaches to the top of the tank. *Note Tank Pressure is 1624 PSI *At end of use, completely empty the tank for recycling. Tank Volume of Gas Product SKU: 130g / 103 Liters / 27 Gallons NITROHYDRO-130G Regulator/Dispenser Details (not included with tank only purchase) Regulator - Adjustable via. needle valve, regulated to 29 PSI. Made in Italy. Thread: M11x1 (tank connection). Output: 1/4" JIC to connect to any of our 1/4" extractor hoses or vacuum hoses. Gauges read in BAR. M11 Valve Dispenser Kit - Includes adjustable pushpin style valve dispenser. Output: 1/4" JIC Flare, NO GAUGE. Connects to any 1/4" JIC Hose.
$34.00 - $139.00
Psilocybin QTests
Psilocybin QTests The Psilocybin QTest is the first and only test kit on the market that can tell you the potency of magic mushrooms. Works with dried mushrooms and extracts. This single-use kit can be used to test any amount of mushrooms you want, so long as they are dried and you grind them up first. Simply follow the instructions and compare the color of the detection vial to the enclosed color chart. It’s that simple. Instructions Note: A paper version of these instructions comes with your order. IMPORTANT INFORMATION! – READ THIS FIRST • Use this kit at room temperature. (If stored in a refrigerator, let it warm up for one hour first.) • Perform the test on a flat surface during the daytime. Evaluate the result in daylight immediately after the 15-minute development time. (The color can change if you wait too long.) • Use a white, letter-sized sheet of paper as a background when evaluating the color. (See section 4, ”Evaluating the Results” for details.) • This kit only works with dried fungal material (solid or powdery substances). It does not work with fresh mushrooms. • Do not open the sealed, glass vial.• Read all the instructions at least once through before beginning the test. 1. BACKGROUND INFORMATION Psilocybin is the main active ingredient naturally present in live fungal tissue. When mushrooms are dried and stored correctly, the psilocybin is preserved. However, so- metimes some of the psilocybin will degrade into psilocin. Psilocin is also an active ingredient. It’s only when mushrooms are dried and stored incorrectly for a long pe- riod of time that the psilocin further degrades into inactive compounds, reducing the potency of the mushrooms. The Psilocybin QTest totals the amount of both active ingredients (psilocybin and psilocin) in your fungal sample. Although we present the total in terms of psilocybin only—because this is the most well-known alkaloid—rest assured the results give you the actual potency of your mushrooms, including both psilocybin and psilocin. IMPORTANT! This kit should only be used on dried mushroom material (e.g., myceli- um, fruiting bodies, sclerotia “truffles”) or dried extracts. DID YOU KNOW? All psilocybin is converted into psilocin in your body, and it’s the psilocin that causes the trip. This is why psilocybin is considered a “prodrug.” It is not biologically active until it converts into psilocin. 2. PREPARING FOR THE TEST Take out all the items from your kit. Along with these instructions, you should have: • protective gloves• plastic extraction vial with a screw cap• glass vial with a tightly sealed lid and septum• 1 ml syringe• syringe filter tip (Sterifilt)• blunt needle• evaluation color chart You will also need a milligram scale, a pot to boil water, a pair of kitchen tongs, and either a small funnel or a creased piece of paper to carefully pour the mushroom material into the extraction vial. (You can make your own paper funnel. Google it!) Before you begin the test you must homogenize your dried mushroom material. A coffee grinder works best. If you do not have a coffee grinder then you can chop your mushrooms finely on a cutting board using a sharp knife. (Starting off with a pair of scissors can make chopping easier.) Then mix the chopped material thoroughly. You will be using 150 milligrams (mg) of material for the test. The result will tell you the percentage of psilocybin per gram in remaining material (in terms of mg/gram). But you must homogenize the material first as described above. This is because psilocybin is not naturally distributed evenly inside of mushrooms. One mushroom can have ten times more or less psilocybin than another mushroom from the same batch. Even within a single mushroom the concentration of psilocybin can vary greatly. Therefore, if you don’t homogenize your material first, the test result will not be accurate for all your remaining material. You can homogenize as much material as you want, but keep in mind that ground up mushrooms will degrade more quickly than whole mushrooms. Keeping them completely dry, sealed, and frozen (“freeze-dried”) will preserve the alkaloids best. 3. PERFORMING THE TEST 3.1 First put on the enclosed nitrile gloves and wear appropriate protective clothing and safety glasses. If you wear contact lenses, remove them. The liquids in the vials con- tain acids which may cause skin irritation or severe eye damage. In the event you come in contact with the liquid, remove the affected clothing immediately and rinse the affected skin area with water for several minutes. In case of eye contact, rinse the affected eye with running water for several minutes. (Keep pets, especially cats, away from the testing area.) 3.2 Carefully weigh 150 mg (0.150 g) of your homogenized material using a milligram scale. For concentrated extracts, use a proportionally lower amount (so that the results fit into the range of the color chart). For example, weigh out 75 mg of material for a 2X extract. Weigh out 15 mg of material for a 10X extract. (You will then need to multiply by the same factor at the end. This will be explained later.) 3.3 Preheat around one liter of water (about four cups) in a pot or kettle on the stove or in a kettle. When the water boils, turn off the stove. (This will save you time when you need to boil the water later in step 3.7.) 3.4 Open the plastic extraction vial and carefully pour in your mushroom material using a small funnel or creased piece of paper. Screw the lid back on tightly and shake the vial for approximately ten seconds. Then put the vial down and wait for 10 minutes. During this waiting period, repeat the shaking process two more times, once at about three minutes, and again around seven minutes. Make sure the vial rests motionless for a few minutes before proceeding to the next step. This allows the particulates to settle and makes it easier to draw up liquid into the syringe through the filter tip. 3.5 Unpack the syringe and the syringe filter tip. Attach the filter tip to the syringe. Remove the lid from the plastic vial. Hold the vial with one hand and with your other hand insert the syringe into the vial. Pull the syringe plunger completely open and hold it there. This will create negative pressure and the syringe will slowly fill up with 1 ml of liquid. Remove the syringe from the plastic vial and disconnect the filter tip. Now unpack the blunt needle, remove its plastic casing and attach it to the syringe. 3.6 Pierce the septum of the glass vial using the blunt needle and inject the entire liquid into the vial evenly with moderate pressure. (Penetrating the septum with the blunt needle requires some force, but protects you from injury.) Make sure that the tip of the syringe does not touch the liquid in the glass vial. Then, before removing the empty syringe, completely fill it with air. This depressurizes the vial and prevents liquid from splashing out when removing the syringe. Remove the syringe and blunt needle from the glass vial. (The liquid in the glass vial may now have a greenish color. This indicates the presence of psilocin in the sample, but does not provide a quantitative result. You still need to incubate the vial in hot water.) 3.7 Heat the water again until it boils. Now remove the pot from the heat source and turn off the stove. The water in the pot should no longer be boiling. It is now at the right temperature. Place the glass vial into the water using a pair of kitchen tongs and incubate it for 15 minutes. (It is okay to completely submerge the vial. Water will not enter through the septum.) 3.8 The solution in the vial will start to change color. After 15 minutes, carefully remove the vial from the water using the kitchen tongs. Be careful not to touch the glass vial with your fingers until it cools down. After a few minutes it will be cool enough to touch. Use the en- closed evaluation color chart to determine the potency of your homogenized material. See the next section, “EVALUATING THE RESULT,” for details. 4. EVALUATING THE RESULT Follow the instructions above before evaluating the result. The evaluation should only take place after the vial has incubated for 15 minutes in the water bath.By comparing the intensity or saturation of the liquid in the vial with the enclosed color chart, you can determine the result visually. Daytime sunlight is best suited for optimal evaluation. If using artificial light, the influence of different color temperatu- res may slightly change the hue. You can still perform the evaluation, but you should take this into account (e.g. high blue content in energy-saving lamps, green discolo- ration when using LED light from cell phones, etc). SPECIFIC EVALUATION INSTRUCTIONS • Use a white, letter-sized sheet of paper as a background.• In daylight or under bright light, hold the glass vial next to the color chart about six to eight inches in front of the white sheet of paper and look through the glass vial head-on. For best results, your eyes should be fairly close to the vial, but no closer than about six to eight inches.• Now compare the color of the liquid in the vial to the color chart. The corre- sponding concentration of psilocybin/psilocin is listed as a percentage as well as a ratio in terms of milligrams per gram of material (mg/gram). • This concentration applies to your remaining homogenized material.• For extracts, you need to multiply by the same factor that you reduced your starting material at the beginning of the process. For example, if you tested a 2X extract and reduced your starting material by a factor of two (75 mg instead of 150 mg), then you need to multiply by two to obtain the correct result. Simi-larly, if you tested a 10X extract (using 15 mg), you will need to multiply by ten.• Do not evaluate the liquid after four hours. At this time the color may no longer be reliable. 5. STORAGE AND SHELF LIFEStore the reagents in the refrigerator (35 – 46 F) and out of direct sunlight for a shelf life of at least 18 months. The extraction liquid may turn slightly yellow over time. That’s okay. It is still usable. 6. WARNINGS• Keep the kit away from children and animals.• When performing the test, wear suitable protective gloves, clothing, and face/eye protection. If you wear contact lenses, remove them before using the test kit.• The liquids contained in the test kit consist of various acids which may cause a corrosive/irritating effect on the skin or severe eye damage/irritation. Avoid contact with the skin, eyes, mouth or clothing.• Should contact with the above-listed areas occur, remove the relevant clothing immediately. Instantly rinse the affected skin areas with water for several mi- nutes. In case of contact with the eyes, immediately rinse them with water for several minutes using both hands to keep the upper and lower eyelids open.• Substances processed with the test kit are not to be consumed! 7. DISCLAIMERS• The result may not be 100 % accurate. Your sample could be adulterated with one or more unknown substances that cross-react with the reagents, affecting the quantitative result.• The result does not mean your sample is safe to consume. It could still contain unwanted substances and impurities that can be harmful or even deadly.• The result does not serve as an identification for the species of mushroom. Psilocybin mushrooms can have a similar appearance to poisonous mushrooms. Mushrooms that do not contain psilocybin could cross-react with the reagents and produce minor stainings. This is a false positive reaction presumably to reactive indole.• The Psilocybin QTest is not a substitute for laboratory analysis.• mIraculix and/or Qtests.org assume no responsibility for the use or misuse ofthe test kit or the results. 9. DISPOSAL OF MATERIALSCheck your local regulations for proper disposal of acids.
$24.95
BVV™ Terpenes Sativa
BVV™ Terpenes Sativa All sales are final. Orders can be refunded prior to fulfillment and shipping but once the order has been fulfilled and/or shipped, no refunds will be issued. Due to the hazardous nature of our product, we are unable to accept returns. BVV™ Terpenes are botanically derived terpenes enhanced with "nature-identical" artificial flavors. These flavors boost the natural flavor profile of the terpenes, providing the user with a more pleasant vaping experience. In order to provide complete transparency and elicit customer confidence, all ingredients are disclosed in the technical data sheet. BVV Sativa Safety Data Sheet SATIVA: This terpene is robust and has a distinct citrus, menthol flavor with a touch of sour. Sativa tends to be more stimulating and gives you an energy boost. It can uplift mood, and may reduce anxiety. Best for daytime to assist with creativity throughout your day. FRAGRANCE: Spicy and Sweet. EFFECT: Tends to be more stimulating. It can uplift mood, and may reduce anxiety. Best for daytime to assist with creativity throughout your day. Storage Requirements: Keep in the original container, lid securely tightened and away from heat, open flames, sunlight, combustible materials, and hot surfaces. Store below 15℃ (60℉). Improper storage can cause terpenes to degrade. Dilution: Terpenes must be diluted prior to use for flavor and effect (1-5% by total volume). Terpenes are oil soluble and mix well with plant extracts, coconut oil, and more. Handle With Care: Can cause skin irritation, do not ingest PRIOR to dilution.
$10.00 - $150.00
BVV Value Pump 3cfm 220V ONLY
BVV Value Pump 3cfm 220V ONLY This is the BVV™ Brand VE115 3CFM Single Stage Vacuum Pump. Single-stage vacuums pump exhaust into a chamber in the pump, which separates the oil from the pumped gas. Then, the oil is returned and the gas is exhausted. Please refer to these charts for vacuum specifications at altitude and conversions: Vacuum at Altitude Chart Vacuum Conversion Chart Key Features: Internal Check Valve Oil Mist Filter Cap Larger Oil Reservoir for longer Oil life Lightweight Rubber Feet for noise dampening Reliable, Economical and Efficient. Specification Free Air Displacement - (CFM) 3CFM # Of Stages 1 Voltage 220v Ultimate Vacuum 5 Pa HP 1/4 Oil Capacity 280ml Weight 15LB Intake Connection 1/4" SAE & JIC Pump Warranty Information Customers using solvents such as stabilization resins (MinWax™, Gator Venom™ etc.), alcohol and other polar solvents must use the vacuum pumps in conjunction with a cold trap for evacuations in excess of 5 minutes. (Excludes Cactus Juice™) If the consumer is using the pump for prolonged periods of time exceeding 5 minutes we require that a cold trap is used or the pump warranty is void. These stabilization resins have the ability to break down the internal components of the pump that are plastic resulting in a seized motor voiding all warranties. When evacuation exceeds 5 minutes these solvents begin to vaporize and then re-condense in the vacuum pump reservoir. Once enough solvent re-condenses in the pump displacing the oil the plastic internal components may begin to warp, melt or seize. The use of a cold trap will condense the vapors prior to making their way to the vacuum pump preventing pump damage due to excessive use. Furthermore, Minwax Wood Hardener™ is not to be used with any vacuum pumps, EVER. (A seized motor will result within the first use.) To prevent these issues from happening to your process, change the Oil after each vacuum pump use, Even if the use time is only 5min.
$70.00
Color Remediation Column CRC w/ Bypass
Color Remediation Column w/ Bypass The CRC is a secondary column used as a filtration cartridge for hydrocarbon and ethanol extraction systems. Filter medias are packed in the column above a triple filtration stack, which aids in the removal of impurities from extracted oils. The CRC features a bypass path, allowing the operator to skip the column in case of a clog. The color remediation process is made simple by bundling the cartridge with the needed filter medias. We have paired the unit with suggested media, supplied in the proper ratio, and a standard operating procedure. The included procedure takes all the guesswork out of filtration, delivering the desired results the first try. Our CRC comes available with 1/4",3/8", and 1/2" MJIC connections, your choice of a 3",4", and 6" diameter spool with a 12" height, and rack mounting brackets standard to accommodate systems of any size. This Kit Includes: Color Remediation Column Rack Mounting Brackets 100 pack of 8 and 20-micron filter papers 1000g or 2.5 kg of Activated Alumina 1000g or 2.5 kg of Silica 60A 1000g or 2.5 kg of Pure-Flo® B80 (81, 5000, 6000 or Color Bleach)*Substitutes 1000g of Celite®545 Instruction Manual
$850.00 - $1,350.00
BVV Compression Extractor End Cap (2) 1.5" x (2) 3/8" Compression x 1/4" Compression
BVV Compression Extractor End Cap (2) 1.5" x (2) 3/8" Compression x 1/4" Compression This End Cap come with (2) 3/8" and (1) 1/4" Female Compression Connection and (2) 1.5" Tri-Clamp ferrule welded to the end cap. They allow the user to adapt and connect a threaded connection to the 1/4" port on a Tri-Clamp lid and the 1.5" Tri-Clamp Connection. These 3 connections are welded on a 6" Tri-Clamp End Cap. Specification Material: 304 Stainless Steel Connection Types: (2) 1.5" Tri-Clamp 6" Tri-Clamp (2) 3/8" and (1) 1/4" Female Compression Connection Standard: 3A
$165.00
BVV™130 Sawtooth Dispersing Shaft
BVV™130 Sawtooth Dispersing Shaft The BVV™130 Sawtooth dispersing shaft is a great choice when for tissue samples or tougher materials due to the nature of the saw-toothed shaft head it can easily rip apart any of these types of media. The 50x5mm dispersing shaft can handle samples from 1-50ml and the 115x10mm shaft can handle volumes ranging from 1-250ml.
$125.00
Solvent Pro Series 18/35 Clamp and Gasket Set
Solvent Pro Series 18/35 Clamp and Gasket Set This is a replacement Clamp and Gasket for 5, 10, 30, and 50L Solvent Pro Rotary Evaporators. This Clamp and Gasket fit an 18mm(0.71") Inner Diameter and 35mm(1.38") Outer Diameter joint. The gasket material is made of Silicone surrounded by a PTFE Envelope.
$35.00
Corken T91-103 Oil-Free Gas Compressor
Corken Gas Compressor Corken's vertical industrial gas compressors offer piston displacement ranging from 2.8 to 117 CFM (4.76 to 198.8 m3/hr) while horizontal gas compressors offer piston displacement ranging from 7.6 to 414 CFM (12.9 to 704 m3/hr). Corken Recovery Pump T91 Corken is a leading manufacturer of industrial compressors designed for liquefied petroleum gas (LPG). The single stage T91 is oil-free and can recover your hydrocarbon gas faster than most recovery pumps on the market. Double Distance piece Triple Packing Oil wipe ring Adjustable packing Screw Features and Benefits: Oil-free gas compression: No product contamination Food grade material: PTFE trim and nickel coated parts Faster recovery time: Allows more production runs Zero psig evacuation pressure: Minimizes waste Self-lubricating PTFE piston rings: Low friction design provides many hours of trouble-free service Quiet operation: Suitable for indoor applications (approximately 85 dBa at three feet) Space saving: Air compressor is not required Adjustable packing screw: Extends life of the packing Cost effective: Does not require air compressor and pneumatic driver. Avoid possible air/propane cross contamination Motor: UL and CSA compliant and suitable for Class 1, Division 1, Group C & D application Operating Specifications Bore of cylinder inches (mm) 3.0 (76.2) Stroke inches (mm) 2.5 (63.5) Piston displacement cfm (m3/hr) Minimum @ 400 RPM 4.1 (7.0) Maximum working pressure psig (bar g) 335 (23.1) Maximum brake horsepower (kW) 7.5 (5.6) Maximum rod load lb (kg) 3,600 (1,632.9) Maximum outlet temperature °F (°C) 350 (177) General Performance Data for Vapor Recovery Compressor speed RPM 700 Vapor temperature °F 70 Final evac pressure psig 0 Maximum working pressure psig (bar g) 335 (23.1) Average recovery rate in lb/hr* Butane: 93Propane: 240 Power Requirements Phase 1Ø Voltage 115/230 VAC Motor Power 3 HP Motor Speed 1750 RPM Motor Frequency 60 Hz Data Sheet
$16,000.00
20L Solvent Pro Evaporating Flask
20L Solvent Pro Evaporating Flask Replacement Evaporating flask for 20L solvent pro rotary evaporators.
$720.00
You have seen 1104 out of 2683 products