BVV Spark Free Series
BVV™ SF6D 6CFM Two Stage Spark Free Vacuum Pump
BVV™ SF6D 6CFM Two Stage Spark Free Vacuum Pump This is the BVV™ SF6D 6CFM Two Stage Spark Free Vacuum Pump Please Refer to these charts for vacuum specifications at altitude and conversions: Vacuum at Altitude Chart Vacuum Conversion Chart Key Features: Internal Check Valve Spark Free Construction Oil Mist Filter Cap Larger Oil Reservoir for longer Oil life Lightweight Rubber Feet for noise dampening Reliable, Economical and Efficient. Models BVVSF6S BVVSF6D BVVSF12D Stage 1 2 2 Ultimate Vacuum (Microns) 75 15 15 Refrigerant Classes A1 Non-Toxic, Non Flammable A2 Non-Toxic, Low Flammability A3 Non-Toxic, High Flammability Dimensions (in) 12.4 x 4.8 x 10.16 13 x 5.5 x 10.7 15 x 6.3 x 11.22 Weight (lbs) 16.5 24.3 33.6 Free Air Displacement 6.4 CFM 6.4 CFM 12.8 CFM Motor Size (HP) RPM 1 HP 3440 RPM Oil Capacity 14.5oz / 410ml 19oz / 410ml 20.6oz / 680ml Voltage 110V 60 Hz Power Cord Hard Wired 3m / 9.8' Power Cord Power Switch Ignition Proof On / Off Switch Operating Temperature Range 32F to 125 F (0C to 52C) Gas Ballast Valve No Yes Yes Intake Fittings Stainless Steel Inlet Fitting with 1/4" SAE & 3/8" JIC Male Ports Pump Warranty Information • Customers using solvents such as stabilization resins (MinWax™, Gator Venom™ etc.), alcohol and other polar solvents must use the vacuum pumps in conjunction with a cold trap for evacuations in excess of 5 minutes. (Excludes Cactus Juice™)• If the consumer is using the pump for prolonged periods of time exceeding 5 minutes we require that a cold trap is used or the pump warranty is void.• These stabilization resins have the ability to break down the internal components of the pump that are plastic resulting in a seized motor voiding all warranties. • When evacuation exceeds 5 minutes these solvents begin to vaporize and then re-condense in the vacuum pump reservoir. Once enough solvent re-condenses in the pump displacing the oil the plastic internal components may begin to warp, melt or seize. The use of a cold trap will condense the vapors prior to making their way to the vacuum pump preventing pump damage due to excessive use. Furthermore, Minwax Wood Hardener™ is not to be used with any vacuum pumps, EVER. (A seized motor will result within the first use.)• To prevent these issues from happening to your process, change the Oil after each vacuum pump use, Even if the use time is only 5min.
$429.56
BVV™ SF6S 6CFM Single Stage Spark Free Vacuum Pump
BVV™ SF6S 6CFM Two Stage Spark Free Vacuum Pump This is the BVV™ SF6S 6CFM Two Stage Spark Free Vacuum Pump Please Refer to these charts for vacuum specifications at altitude and conversions: Vacuum at Altitude Chart Vacuum Conversion Chart Key Features: Internal Check Valve Spark Free Construction Oil Mist Filter Cap Larger Oil Reservoir for longer Oil life Lightweight Rubber Feet for noise dampening Reliable, Economical and Efficient. Models BVVSF6S BVVSF6D BVVSF12D Stage 1 2 2 Ultimate Vacuum (Microns) 75 15 15 Refrigerant Classes A1 Non-Toxic, Non Flammable A2 Non-Toxic, Low Flammability A3 Non-Toxic, High Flammability Dimensions (in) 12.4 x 4.8 x 10.16 13 x 5.5 x 10.7 15 x 6.3 x 11.22 Weight (lbs) 16.5 24.3 33.6 Free Air Displacement 6.4 CFM 6.4 CFM 12.8 CFM Motor Size (HP) RPM 1 HP 3440 RPM Oil Capacity 14.5oz / 410ml 19oz / 410ml 20.6oz / 680ml Voltage 110V 60 Hz Power Cord Hard Wired 3m / 9.8' Power Cord Power Switch Ignition Proof On / Off Switch Operating Temperature Range 32F to 125 F (0C to 52C) Gas Ballast Valve No Yes Yes Intake Fittings Stainless Steel Inlet Fitting with 1/4" SAE & 3/8" JIC Male Ports Pump Warranty Information • Customers using solvents such as stabilization resins (MinWax™, Gator Venom™ etc.), alcohol and other polar solvents must use the vacuum pumps in conjunction with a cold trap for evacuations in excess of 5 minutes. (Excludes Cactus Juice™)• If the consumer is using the pump for prolonged periods of time exceeding 5 minutes we require that a cold trap is used or the pump warranty is void.• These stabilization resins have the ability to break down the internal components of the pump that are plastic resulting in a seized motor voiding all warranties. • When evacuation exceeds 5 minutes these solvents begin to vaporize and then re-condense in the vacuum pump reservoir. Once enough solvent re-condenses in the pump displacing the oil the plastic internal components may begin to warp, melt or seize. The use of a cold trap will condense the vapors prior to making their way to the vacuum pump preventing pump damage due to excessive use. Furthermore, Minwax Wood Hardener™ is not to be used with any vacuum pumps, EVER. (A seized motor will result within the first use.)• To prevent these issues from happening to your process, change the Oil after each vacuum pump use, Even if the use time is only 5min.
$300.69
BVV™ SF12D 12CFM Two Stage Spark Free Vacuum Pump
BVV™ SF12D 12CFM Two Stage Spark Free Vacuum Pump This is the BVV™ SF12D 12CFM Two Stage Spark Free Vacuum Pump. Please Refer to these charts for vacuum specifications at altitude and conversions: Vacuum at Altitude Chart Vacuum Conversion Chart Key Features: Internal Check Valve Spark Free Construction Oil Mist Filter Cap Larger Oil Reservoir for longer Oil life Lightweight Rubber Feet for noise dampening Reliable, Economical and Efficient. Models BVVSF6S BVVSF6D BVVSF12D Stage 1 2 2 Ultimate Vacuum (Microns) 75 15 15 Refrigerant Classes A1 Non-Toxic, Non Flammable A2 Non-Toxic, Low Flammability A3 Non-Toxic, High Flammability Dimensions (in) 12.4 x 4.8 x 10.16 13 x 5.5 x 10.7 15 x 6.3 x 11.22 Weight (lbs) 16.5 24.3 33.6 Free Air Displacement 6.4 CFM 6.4 CFM 12.8 CFM Motor Size (HP) RPM 1 HP 3440 RPM Oil Capacity 14.5oz / 410ml 19oz / 410ml 20.6oz / 680ml Voltage 110V 60 Hz Power Cord Hard Wired 3m / 9.8' Power Cord Power Switch Ignition Proof On / Off Switch Operating Temperature Range 32F to 125 F (0C to 52C) Gas Ballast Valve No Yes Yes Intake Fittings Stainless Steel Inlet Fitting with 1/4" SAE & 3/8" JIC Male Ports Pump Warranty Information • Customers using solvents such as stabilization resins (MinWax™, Gator Venom™ etc.), alcohol and other polar solvents must use the vacuum pumps in conjunction with a cold trap for evacuations in excess of 5 minutes. (Excludes Cactus Juice™)• If the consumer is using the pump for prolonged periods of time exceeding 5 minutes we require that a cold trap is used or the pump warranty is void.• These stabilization resins have the ability to break down the internal components of the pump that are plastic resulting in a seized motor voiding all warranties. • When evacuation exceeds 5 minutes these solvents begin to vaporize and then re-condense in the vacuum pump reservoir. Once enough solvent re-condenses in the pump displacing the oil the plastic internal components may begin to warp, melt or seize. The use of a cold trap will condense the vapors prior to making their way to the vacuum pump preventing pump damage due to excessive use. Furthermore, Minwax Wood Hardener™ is not to be used with any vacuum pumps, EVER. (A seized motor will result within the first use.)• To prevent these issues from happening to your process, change the Oil after each vacuum pump use, Even if the use time is only 5min.
$708.78
BVV™ 6CFM Single Stage Spark Free Pump
BVV™ 6CFM Single Stage Spark Free Pump This is the brand new BVV™ 6CFM Single Stage Spark Free Pump. It is is a reliable and efficient pump that is designed for use in hazardous locations without the risk of ignition. Please Refer to these charts for vacuum specifications at altitude and conversions: Vacuum at Altitude Chart Vacuum Conversion Chart Key Features: Spark Free Operation 1/4" and 3/8" Flared connections. Internal Check Valve Oil Mist Filter Cap Larger Oil Reservoir for longer Oil life Lightweight Rubber Feet for noise dampening Reliable, Economical and Efficient. Specifications No. of Stages: 1 Free Air Displacement: 6CFM Voltage 110v / 60Hz Ultimate Vacuum 75 Micron Motor Speed 2880 Oil Capacity 650ml Weight 19LB Intake Connection 1/4" SAE, 3/8" SAE Pump Warranty Information Customers using solvents such as stabilization resins (MinWax™, Gator Venom™ etc.), alcohol and other polar solvents must use the vacuum pumps in conjunction with a cold trap for evacuations in excess of 5 minutes. (Excludes Cactus Juice™) If the consumer is using the pump for prolonged periods of time exceeding 5 minutes we require that a cold trap is used or the pump warranty is void. These stabilization resins have the ability to break down the internal components of the pump that are plastic resulting in a seized motor voiding all warranties. When evacuation exceeds 5 minutes these solvents begin to vaporize and then re-condense in the vacuum pump reservoir. Once enough solvent re-condenses in the pump displacing the oil the plastic internal components may begin to warp, melt or seize. The use of a cold trap will condense the vapors prior to making their way to the vacuum pump preventing pump damage due to excessive use. Furthermore, Minwax Wood Hardener™ is not to be used with any vacuum pumps, EVER. (A seized motor will result within the first use.) To prevent these issues from happening to your process, change the Oil after each vacuum pump use, Even if the use time is only 5min.
$286.37$229.10