Products
Magnetic PTFE Stir Bar Retriever
Magnetic PTFE Stir Bar Retriever Magnetic PTFE Stir Bar Retriever is used to retrieve the stirring bar from a boiling flask. Specifications: 400mm Length Material: High Temperature PTFE
$21.08
Magnetic PTFE Stirring Bar - L Style - 70mm
Magnetic PTFE Stir Bar - L Style - 70mm Reduce stir bar jumping with the contoured shape of this L Style Magnetic PTFE Stir Bar. Ideal for round-bottom flask stirring applications. This 70mm L Style Magnetic Stir bar is great for round-bottom flasks above 5 liters in capacity. With its PTFE coating this Magnetic Stir Bar carries excellent solvent and temperature compatibility for a variety of applications. Specifications: L Style 70mm Length Material: High-temperature PTFE
$21.08
MagSil-PR® Adsorbent for Chromatography
MagSil-PR® Adsorbent for Chromatography BVV™ MagSil-PR® Adsorbent for Chromatography is an adsorbent for the separation of lipids and is a commercially prepared magnesia-silica gel. MagSil-PR® has a coarse mesh size which helps with rapid flow rate for column chromatography. It's main benefit is pesticide removal from extracted plant material and will dramatically improve the color and clarity of the material. It also has the provided benefit to bind to polar water-soluble compounds which can be filtered out through a 20-micron mesh screen. Particle Mesh Size: 60/100 BVV™ MagSil-PR® SDS
$207.95 - $2,634.51
Male Adapter
SSP - Male Adapter SSP Instrumentation Duolok® tube fittings are designed, manufactured and quality controlled to be totally “interchangeable” with the Swagelok® brand of tube fittings. Component by component examination plainly shows the two brands as completely “componentintermixable.” The precision manufacturing of both products to stringent tolerances under rigid quality control procedures ensures the safety, performance, and reliability of service whenever Duolok® and Swagelok® component parts are mixed and used in accordance with published installation and service recommendations. Specifications: Connection Type 1 Duolok Tube Fitting Connection Size 1 Specified by User Connection Type 2 Male NPT Connection Size 2 Specified by User Material 316 Stainless Steel ASTM A-276 and A-479 bar stock, A-182 forgings. Duolok Pressure Rating = Tubing Rating NPT Pressure Rating >10,000PSI ASME B31.3 SSP proudly makes Duolok®, TruFit®, FloLok® and hundreds of other products 100% in the USA!
$5.62 - $7.03
Male Connector
SSP - Male Connector SSP Instrumentation Duolok® tube fittings are designed, manufactured and quality controlled to be totally “interchangeable” with the Swagelok® brand of tube fittings. Component by component examination plainly shows the two brands as completely “componentintermixable.” The precision manufacturing of both products to stringent tolerances under rigid quality control procedures ensures the safety, performance, and reliability of service whenever Duolok® and Swagelok® component parts are mixed and used in accordance with published installation and service recommendations. Specifications Connection Type 1 Duolok Tube Fitting Connection Size 1 Specified by User Connection Type 2 Male NPT Connection Size 2 Specified by User Material 316 Stainless Steel ASTM A-276 and A-479 bar stock, A-182 forgings. Duolok Pressure Rating = Tubing Rating NPT Pressure Rating >10,000PSI ASME B31.3 SSP proudly makes Duolok®, TruFit®, FloLok® and hundreds of other products 100% in the USA!
$22.48 - $25.29
Male Connector Bore Through
SSP - Male Connector Bore Through SSP Instrumentation Duolok® tube fittings are designed, manufactured and quality controlled to be totally “interchangeable” with the Swagelok® brand of tube fittings. Component by component examination plainly shows the two brands as completely “componentintermixable.” The precision manufacturing of both products to stringent tolerances under rigid quality control procedures ensures the safety, performance, and reliability of service whenever Duolok® and Swagelok® component parts are mixed and used in accordance with published installation and service recommendations. ***Note: This fitting allows the user to have the corresponding tube size completely THROUGH the connector. Specifications Connection Type 1 Duolok Tube Fitting Connection Size 1 Specified by User Connection Type 2 Male NPT Connection Size 2 Specified by User Material 316 Stainless Steel ASTM A-276 and A-479 bar stock, A-182 forgings. Duolok Pressure Rating = Tubing Rating NPT Pressure Rating >10,000PSI ASME B31.3 SSP proudly makes Duolok®, TruFit®, FloLok® and hundreds of other products 100% in the USA!
$19.67 - $39.34
Male Elbow
SSP - Male Elbow SSP Instrumentation TruFit® is manufactured from fully-traceable raw material to close tolerances and superior surface finishes. TruFit® provides optimal performance when installed in accordance with SSP’s recommendations and the design parameters appropriate for each type of connection – tapered thread, straight thread, and weld & braze. TruFit® components are cleaned in accordance with SSP documented work instructions using equipment calibrated to NIST standards with environmentally-safe and stable agents, ultrasonics, and heat/ temperature to remove all residual oil, grease, and loose particles. Stainless steel components are passivated to the requirements of MIL QQ-P-35 and ASTM A 967. ***Note: ALL NPT Threads REQUIRE the user to properly install the fitting by using a thread sealant to prevent leaks. Best Value Vacs recommends GAS PTFE Tape Specifications Connection Type 1 Male NPT Connection Size 1 Specified by User Material 316 Stainless Steel ASTM A-276 and A-479 bar stock, A-182 forgings. Working Pressure (PSIG) 1/4" - 7750 3/8" - 6800 NPT Pressure Rating >10,000PSI ASME B31.3 SSP proudly makes Duolok®, TruFit®, FloLok® and hundreds of other products 100% in the USA!
$21.08
Male Elbow
BVV™ Male Elbow BVV™ brand stainless steel parts are made with precision 304 Grade Stainless Steel and are clean and free from burrs or debris. These fittings are NPT threads (National Pipe Taper) and will compress against other Female/Male NPT threads creating a tighter and tighter connection. All NPT threads require thread sealant to create a watertight and gas-tight seal between the threads. We recommend using Yellow Gas PTFE Tape because it is rated for gases and is UL listed and it is NOT recommended to use white PTFE tape because it is not rated for gas service. **NOTE: Pre-Taped option comes from BVV Pre-taped with Yellow UL Listed Gas PTFE Tape on the Male NPT threads ONLY for a +0.50c charge per male npt end. (JIC Threads DO NOT need to be taped.) MNPT Elbows allow the user to sharply turn the flow of the system by 90 degrees allowing for more clearance or better positioning of the fitting or valve on the extraction system. BVV™ Male Elbow - Data Sheet Specifications Material 304 Stainless Steel Connection Type(s): 1/4"-18 FNPT 3/8"-18 FNPT Sizes Available: 1/4" 3/8"
$8.43
Male Elbow Tube Fitting
SSP - Duolok Male Elbow SSP Instrumentation Duolok® tube fittings are designed, manufactured and quality controlled to be totally “interchangeable” with the Swagelok® brand of tube fittings. Component by component examination plainly shows the two brands as completely “componentintermixable.” The precision manufacturing of both products to stringent tolerances under rigid quality control procedures ensures the safety, performance, and reliability of service whenever Duolok® and Swagelok® component parts are mixed and used in accordance with published installation and service recommendations. Specifications Connection Type 1 Duolok Tube Fitting Connection Size 1 Specified by User Connection Type 2 Male NPT Connection Size 2 Specified by User Material 316 Stainless Steel ASTM A-276 and A-479 bar stock, A-182 forgings. Duolok Pressure Rating = Tubing Rating NPT Pressure Rating >10,000PSI ASME B31.3 SSP proudly makes Duolok®, TruFit®, FloLok® and hundreds of other products 100% in the USA! Dimensions A 1.06 in Bx 0.77 in By 0.92 in C 0.70 in D 0.60 in E 0.19 in F 0.56 in G 9/16 in H 1/2 in P 1/4 in T 1/4 in
$11.24 - $42.15
Male Hollow Stopper
Male Hollow Stopper Male Hollow Stoppers are used for capping off or plugging a female join to prevent contamination or close off a port on a glassware system. These glass stoppers are hollow on the inside and require vacuum grease to create a seal when having 2 ground surfaces touching in a vacuum application. Joint Sizes Available: 14/20 Ground Joint 24/40 Ground Joint *Notice to customers: All units are inspected for broken glassware or parts before leaving BVV™. If the unit arrives damaged (this does not include minor imperfections or scuffs in glassware), the customer MUST contact BVV™ within 72 hours from carrier delivery to file a claim. If the customer DOES NOT contact BVV™ within 72 hours from carrier delivery, then BVV™ cannot issue any replacement(s) or compensation for the item; a new purchase will need to be made for a replacement. **Glassware Safety Disclaimer: BVV™ is not responsible for failure of glassware which must be inspected before and after every use because it may eventually develop imperfections or damage through normal usage, mishandling, and stress caused by temperature variations. If an imperfection or damage is noted while inspecting the glassware DO NOT use the glassware because it can fail causing bodily harm or damage to the surrounding area.**
$11.24 - $15.46
Male Luer to 1/4 NPT Male Nickle Plated Brass
Male Luer to 1/4 NPT Male, Fitting Material Brass- Nickle Plated.
$28.10
Male Run Tee
SSP - Male Run Tee SSP Instrumentation Duolok® tube fittings are designed, manufactured and quality controlled to be totally “interchangeable” with the Swagelok® brand of tube fittings. Component by component examination plainly shows the two brands as completely “componentintermixable.” The precision manufacturing of both products to stringent tolerances under rigid quality control procedures ensures the safety, performance, and reliability of service whenever Duolok® and Swagelok® component parts are mixed and used in accordance with published installation and service recommendations. Specifications Connection Type 1 Duolok Tube Fitting Connection Size 1 Specified by User Connection Type 2 Duolok Tube Fitting Connection Size 2 Specified by User Connection Type 3 Male NPT Connection Size 3 Specified by User Material 316 Stainless Steel ASTM A-276 and A-479 bar stock, A-182 forgings. Duolok Pressure Rating = Tubing Rating NPT Pressure Rating >10,000PSI ASME B31.3 SSP proudly makes Duolok®, TruFit®, FloLok® and hundreds of other products 100% in the USA! Dimensions A 1.98 in Bx 0.77 in By 0.92 in C 0.70 in D 0.60 in E 0.19 in F 0.56 in G 9/16 in H 9/16 in P 1/4 in T 1/4 in Ax 1.06 in B 1.69 in
$42.15$29.51
Male Tee
SSP - Male Tee SSP Instrumentation TruFit® is manufactured from fully-traceable raw material to close tolerances and superior surface finishes. TruFit® provides optimal performance when installed in accordance with SSP’s recommendations and the design parameters appropriate for each type of connection – tapered thread, straight thread, and weld & braze. TruFit® components are cleaned in accordance with SSP documented work instructions using equipment calibrated to NIST standards with environmentally-safe and stable agents, ultrasonics, and heat/ temperature to remove all residual oil, grease, and loose particles. Stainless steel components are passivated to the requirements of MIL QQ-P-35 and ASTM A 967. ***Note: ALL NPT Threads REQUIRE the user to properly install the fitting by using a thread sealant to prevent leaks. Best Value Vacs recommends GAS PTFE Tape Specifications Connection Type 1 Male NPT Connection Size 1 Specified by User Material 316 Stainless Steel ASTM A-276 and A-479 bar stock, A-182 forgings. Working Pressure (PSIG) 1/4" - 7750 3/8" - 6800 NPT Pressure Rating >10,000PSI ASME B31.3 SSP proudly makes Duolok®, TruFit®, FloLok® and hundreds of other products 100% in the USA!
$28.10$16.86
Malt Extract Powder for Mushrooms Mycology
Malt Extract Powder Our Agar Powder is extracted from Red Seaweed. Our agar is a complex polysaccharide and is a top choice for mycology cultures. This superfine agar dissolves quickly and has a high gel strength making it an excellent choice for a variety of applications an petri dishes. STORAGE: Cool dry conditions, sealed original package Mix: Mix: 10 gram per. 500ml pH: 5.88 TASTE & ODOR: Sweet, malty in taste and smell. SOLUBILITY: Soluble in water. CLARITY IN WATER: Clear TOTAL PROTEIN CONTENT: 5.19% TOTAL CARBOHYDRATE: 72.98% W/W YEAST AND MOLDS:: 150CFU/gm E.COLI: NEGATIVE SALMONELLA: NEGATIVE STA{HYLOCOCCUS AUREUS: NEGATIVE SHELFLIFE: 4 years GEL STRENGTH(1.5%) 900 gm/cm Minimum CAS# N/A Directions for Use: Mix 10g of malt extract powder per 500ml of distilled water, as a nutritional additive in your agar or liquid culture formulation. Boil and stir until powder is fully dissolved. Sterilize the mixture for 45min @15psi 250°F (121°C) in a pressure cooker or autoclave. Allow mixture to cool to approximately 122°F (50°C) *To avoid excessive condensation
$18.27 - $88.52
Master Vapor MVP Liquid Recovery Pump
Master Vapor MVP Liquid Recovery Pump THE NEW LIQUID Pumps solvent in liquid state Hydrocarbon and ethanol compatible C1D1 and 3rd party Certified Drastically increases evaporation byexpanding surface area andcreating turbulence Electric Driven FDA Food Grade Compliant MADE IN THE USA Engineering Specifications: Maximum pumping outlet pressure - 70 PSI Center Section CO2 charge range 5 to 80 PSI(10-15psi over inlet pressure recommended) CO2 Inlet Size: 1 /4 in. npt(f) Maximum Pump Speed 135 cpm (cycle per minute) Process Inlet and Outlet Size: 1 in. npt Electric Motor: Explosion proof for C101 Hazardous areas Motor Specifications: 2HP, 3,600 rpm, 60Hz Size: 18.3” x 15.4” base x 42.3” tall Weight: 173.2 lb All sales final Technical Data sheet US Metric Maximum Pumping outlet Pressure 70 PSI 0.48 MPa, 4.8 bar Center section CO2 Change range 6 to 80 PSI 0.03-0.55 MPa 0.3-5.5 bar Equipment Withstand Pressure 350 PSI 2.41 MPa, 24.1 bar Maximum CO2 Consumption <0.2 scfh <0.006 cubic meters/hour CO2 inlet size 1/4 in. npt(f) Maximum Pump Speed 135 cpm Process intel and outlet size 1 in. npt Model MVP Liquid, 3 ph, Inverter Rated Power 2 HP 1.5kW Speed 3600 rp, (60 Hz) Gear Ratio 25.85 Voltage 1-phase 208-230/460V Maximum Amperaage Load 5.2 A (230V / 2.6 A (460V) Model MVP Liquid 1PH Power 2 HP 1.5kW Speed 3600 rpm (60 Hz) Gear Ratio 25.85 Maximum Amperaage Load 5.2 A (115V / 10 A (230V) Noise Data Sound Power (measured per ISO-9614-2 88.5 dBa Sound Pressure {Tested 3.28ft (1m) From Equipment} 80.5dBa Materials Process Pressure Section and Reed Valves Stainless Steel Diaphragms Standard: FKM Fluoroelastomer Optional:PTFE Process Vapor Temperature Range FKM: -40 to 275 °F (-40 to 135 C)PTFE: +40 to 220 °F 9+4 to 104 C
$19,249.52 - $20,022.31
Master Vapor MVP Recovery Pump - 60 PSI
Master Vapor MVP Recovery Pump - 60 PSI The Master Vapor Pump Model MVP-6CFM is a certified gas recovery pump designed to operate at 60 PSI. This pump is designed specifically for LP-Gas vapor recovery and is ideal for butane or butane / propane mixtures. Engineering Specifications: Recover LP-Gas vapor at OVER 6 CFM (cubic feet per minute) Recover butane at up to 1 LB/MIN (pounds per minute) Recover and recondense butane at OVER 12 GPH (gallons per hour) Electric motor: explosion proof for C1D1 hazardous areas; rated Class I Gr C & D, Class II Gr F&G Electric motor: 1 HP, 1800 RPM, 60 HZ Pump speed: 190 CPM (cycles per minute) at 60 HZ Size: 17.0” x 19.9” base x 46” tall Weight: 182.5 lb (82.8 kg) Motor Option: Model MVP-6CFM-1PH: Single-phase: 115/208-230V, 13.4/6.7 FLA (full load amps) Model MVP-6CFM-3PH: Three-phase: 208-230/460V, 3.3/1.65 FLA, Inverter-rated Documentation: Product Manual Technical Data Sheet Features and Benefits Sheet
$13,446.56
Master Vapor MVP-150XL Diaphragm
Master Vapor MVP-150XL Diaphragm Diaphragm replacement kit for use with the MVP-150XL recovery pump. Unit of Measure: EA Height: 2 IN | 5.08 CM Length: 12 IN | 30.48 CM Width: 12 IN | 30.48 CM Volume: .167 FT3 | .005 M3 Chargeable Weight: 2.58 LBS | 1.17 KG
$576.08
Master Vapor MVP150 Explosion Proof Recovery Pump
Master Vapor MVP Recovery Pump - 150 PSI (This item may carry up to a 2-4 week lead time) (This item is limited to a maximum of 10% discount during sales) The Master Vapor Pump Model MVP-150-1PH is a certified gas recovery pump designed to operate at 150 PSI. This pump is designed specifically for LP-Gas vapor recovery and is ideal for butane or butane / propane mixtures. Please note that the standard Single Phase and Three Phase models are UL Certified and that the ATEX Three Phase is CE Certified. Engineering Specifications: Recover LP-Gas vapor at OVER 6 CFM (cubic feet per minute). Recover butane at up to 1.5 LB/MIN (pounds per minute) Recover and recondense butane at OVER 18 GPH (gallons per hour) Electric motor: explosion proof for C1D1 hazardous areas; rated Class I Gr C & D, Class II Gr F&G Electric motor: 2 HP, 3600 RPM, 60 HZ. Pump speed: 220 CPM (cycles per minute) at 60 HZ. Size: 17.0” x 19.9” base x 46” tall Weight: 182.5 lb (82.8 kg) Motor Option: Model MVP-150-1PH : Single-phase: 115/208-230V, 20/10 FLA (full load amps) - UL Certification Model Model MVP-150-3PH : Three-phase: 208-230/460V, 5.2/2.6A FLA, Inverter-rated - UL Certification Compliance Details: Compliant with NFPA and UL standards for C1D1 motors and LPG vapor recovery Meets Class 1 Division 1 hazardous area facility requirements (when installed correctly) One year manufacturer’s warranty (see Operation Manual) Made in the USA Documentation: Product Manual Technical Data Sheet Features and Benefits sheet
$18,209.77
Master Vapor Pumps - MVP Recovery Pump - XL 150 PSI
Master Vapor Pumps - MVP Recovery Pump - XL 150 PSI The Master Vapor Pump Model MVP-150XL is a certified gas recovery pump designed to operate at 150 PSI. It can handle over three times the volume of vapor as our standard MVP-150. This pump is designed specifically for LP-Gas vapor recovery and is ideal for butane or butane / propane mixtures. Please note that this model of the MVP 150 only comes with Three-phase power options available. Engineering Specifications: Recover LP-Gas vapor at OVER 18 CFM (cubic feet per minute) Recover butane at up to 4.5 LB/MIN (pounds per minute) Recover and re-condense butane between 35-50 GPH (gallons per hour) Electric motor: explosion proof for C1D1 hazardous areas; rated Class I Gr C & D, Class II Gr F&G Electric motor: 5 HP, 1800 RPM, 30 HZ Pump speed: 174 CPM (cycles per minute) at 60 HZ Size: 17.0” x 22.8” base x 46.4” tall Weight: 360.5 lb (163 kg) All sales final
$25,965.78
Mastercool 1/4" FNPT Vacuum Pump Exhaust Adapter
Mastercool 1/4" FNPT Vacuum Pump Exhaust Adapter This fitting allows the user to connect a 1/4" NPT fitting to the exhaust for the desired application such as a carbon exhaust filter. It is made of brass and comes with a Viton O-ring. This item will also fit VE115 Vacuum pumps
$14.05
Mastercool Blue 60" HVAC Hose
This HVAC hose will fit 1/4" SAE or JIC fittings. One end of the hose has a fitting made to depress a Schrader valve within the male fitting, the other end of the hose is a standard connection.
$21.08
Mastercool Manifold
Mastercool Manifold Mastercool Aluminum R12 Manifold: THE MASTERCOOL MANIFOLD IS USED IN CONJUCTION WITH BOTH OUR ACTIVE UPGRADE KIT AND OUR ICARUS RACK SYSTEMS. WHEN USED IN AN ACTIVE CLOSED LOOP RECOVERY/CIRCULATION KIT, THE MANIFOLD ALLOWS FOR CONTROL OF SOLVENT INPUT VIA EXTRACTOR INPUT ON THE LOW SIDE(BLUE GAUGE), AND RECOVERY TO YOUR SUPPLY TANK ON THE HIGH SIDE (RED GAUGE). WHEN USED WITH ONE OF OUR ICARUS RACK SYSTEMS, THE MIDDLE PORT IS CONNECTED TO A SEPERATE NITROGEN SUPPLY TANK, AND THE HIGH AND LOW SIDES ARE CONNECTED TO THE MATERIAL COLUMN AND DEWAXER TO PROVIDE PASSIVE PRESSURE ASSISTANCE FOR MOVING SOLVENT THROUGH THE SYSTEM. Mastercool is the leading manufacturer of professional quality A/C manifold gauge sets. Our manifold gauge sets are. Constructed of the finest materials and machined with precision to the highest quality standards. At Mastercool, everymanifold we build is built to last. All Mastercool gauges are color coordinated for easy refrigerant recognition. Our free floating piston valve results in less wear and tear in comparison to market standard twisting piston valves Double O-Ring allows for a much better seal resulting in less leaks SPECIFICATIONS: Aluminum Block ¼ SAE Brass Fittings 1.6 Gauge Class 80 mm Gauges Refrigerants: R1270, R290, R600a Bar, PSI, ˚C Temp. Ratings: 100˚C Pressure Ratings: High Side 800 PSI, Low Side 500 PSI Temp.: Different for each Refrigerant
$70.25
Mastercool Nitrogen Pressure Regulator Kit
Mastercool Nitrogen Pressure Regulator Kit Product Description Mastercool’s new nitrogen regulator is specifically designed to meet the specifications of HVAC/R and automotive A/C systems. This single stage nitrogen regulator is used to test systems for leaks when they do not contain refrigerant. 1/4” SAE flare outlet port, with control valve, to keep pressure on the regulator at all times T-Handle for ease of pressure adjustment 63 mm (2 1/2”) gauges with guards High pressure gauge 4400 psig (300 bar) Low pressure gauge 1000 psig (70 bar)
$266.96
MasterCool Vacuum Pump Activated Carbon Exhaust Filter
Carbon Exhaust Filter for MasterCool Pumps Replaces Koby Junior (US Patent# 3169112A) MasterCool Vacuum Pump Activated Carbon Filter for use with Mastercool pumps. This filter will adsorb contaminants such as oil aerosols, oil vapors, certain other hydrocarbon vapors, and trace moisture. They also trap all foreign solid particles and bacteria down to 0.5 microns in size. Key Features: Purifies Exhaust Gases from Vacuum Pumps Up to 19 CFM 0.5 Micron Filtration levels. Helps Maintain Safe Working Environment Adsorbs Organic Vapors and Small Particles High-Efficiency Filtration Minimal Pressure Drop Maintenance Free - Completely Disposable Pressure Safe to 90 PSI Brass M24 x 1.0 Pump Connection Filter connections 1/4" NPT Pipe Fitting Connections Removes the following contaminants: Oil Mist Oil Aerosols Oil Vapors Hydrocarbon Vapors Moisture Droplets Dust Pipe Scale Rust Fine Particles Odors Organic Aerosols Other Foreign Matter Lifespan:720 hrs. of continuous operation. (Then replacement is recommended) *NOTE PUMP NOT INCLUDED
$161.58
MCT Oil Coconut Based USP Food Grade
MCT Oil Coconut Based USP Food Grade 60/40 - 60%C8 / 40%C10 Soy Free, Non-GMO, Gluten Free, Dye Free, Dairy Free/Vegan Medium Chain Triglycerides (MCT’s) are fats that are naturally found in coconut and palm kernel oil. MCT’s are more easily and rapidly digested than other types of fats, as they require lower amounts of enzymes and bile acids for intestinal absorption. MCT’s are metabolized very quickly in the liver and are reported to encourage energy expenditure, and not fat storage. Numerous studies suggest that substituting MCT Oil for other fats in a healthy diet may therefore help to support healthy weight and body composition.* Suggested Usage As a dietary supplement, take 1 tablespoon (15 mL) 1 to 3 times daily. MCT Oil can also be used as a substitute for conventional oils in salad dressings, sauces or cooking as a source of beneficial fatty acids. Not recommended for use in frying due to low boiling point Caution: For adults only. MCT Oil may cause GI upset. To reduce these effects, take with food. Consult physician if pregnant/nursing, taking medication, or have a medical condition. Keep out of reach of children. Storage Guidance: Store in a cool, dry and dark environment in a tightly sealed original container. After opening, product can be refrigerated or stored at cool room temperature. Please note*** These statements have not been evaluated by the Food and Drug Administration. This product is not intended to diagnose, treat, cure or prevent any disease. BVV MCT Oil - COA BVV MCT Oil - SDS
$30.91 - $2,950.66
MDMA QTests (Basic)
MDMA QTests (Basic) Know your dose with the MDMA QTest The MDMA QTest is the first and only quantitative MDMA test kit on the market for ecstasy and molly. This single-use kit can tell you the potency of MDMA powder or crystals, or how many milligrams of MDMA are in a pressed ecstasy tablet. Use only a small amount, then compare the color of the detection vial with the enclosed color chart. It’s that simple. This Kit is Only for Determining Potency This is our Basic MDMA QTest, which means it is only for detecting potency. It cannot tell you whetherwhether you have MDMA to begin with. Only buy this kit if you already know you have MDMA. Many companies sell qualitative test kits for detecting MDMA. You may want to use one of those first. However, you can also buy our Advanced MDMA QTest that comes with two smaller, confirmation tests. That kit will tell you whether you actually have MDMA, and also detects counterfeit samples containing amphetamine, methamphetamine, caffeine, MDA (or MDA-MDMA combinations), PMA, PMMA or 2C-B. Instructions Note: A paper version of these instructions comes with your order. IMPORTANT INFORMATION! – READ THIS FIRST• Make sure you have real MDMA before using this kit. If you have MDA, 6-APB or 5-MAPB instead, the kit will produce a similar reaction, but it won’t be accurate. Many companies sell multi-use MDMA test kits that give qualitative results (just not quantitative). Use one of those kits first, or buy our Advanced MDMA QTest. • Use this kit at room temperature. (If stored in a refrigerator, let it warm up for one hour first.) • Perform the test on a flat surface during the daytime. • Evaluate the result in daylight immediately after the 12-minute development time. (The color can change if you wait too long.) • Use a white, letter-sized sheet of paper as a background when evaluating the color. (See section four for evaluation details.) • This kit should only be used on pills, powders and crystals. It does not work on liquids. • Read all the instructions at least once through before beginning the test. 1. BACKGROUND INFORMATION This quantitative test kit can be used to detect the concentration of MDMA in powders, crystals and pills (including pressed tablets of any color) that have first been verified to contain MDMA. (Use a qualitative MDMA test kit first to make sure you have MDMA, or buy our Advanced MDMA QTest, which contains two extra qualitative tests.) 2. PREPARING FOR THE TEST Take out all the items from your kit. Along with these instructions, you should have: • protective gloves• thin glass vial with black lid (extraction vial)• large glass vial with white lid (detection vial)• plastic dropper bottle with green lid• pipette• evaluation color chart You will also need a milligram scale and either a small funnel or a creased piece of paper to carefully pour the measured powder or crystals into the extraction vial. (You can make your own paper funnel. Google it!) 3. PERFORMING THE TEST 3.1 First put on the enclosed nitrile gloves and wear appropriate protective clothing and safety glasses. If you wear contact lenses, remove them. The liquids in the vials contain acids which may cause skin irritation or severe eye damage. In the event you come in contact with the liquid, remove the affected clothing immediately and rinse the affected skin area with water for several minutes. In case of eye contact, rinse the affected eye with running water for several minutes. Perform the test either outdoors or in a well-ventilated area and avoid inhaling the fumes, which can cause dizziness. (Keep pets, especially cats, away from the testing area.) 3.2 Using a milligram scale, carefully weigh out 30 mg of powder or crushed crystals. If you are testing a pressed ecstasy tablet, use 50 mg. You can either scrape off 50 mg from the edge of the tablet using a sharp knife, or even better, crush and mix the entire tablet and then weigh out 50 mg of the resulting powder. IMPORTANT! – If you are testing a pressed ecstasy tablet, weigh the entire tablet first and write down the result. You will need to know the total weight of the tablet in order to calculate how much MDMA it contains after testing 50 mg. 3.3 Open the thin extraction vial (with the black lid) and use a funnel or creased piece of paper to carefully pour in the 30 mg of powder or crystals (or 50 mg if testing a pressed tablet). Put the lid back on the vial and close it tightly. Shake the vial for approximately one minute (or until all the soluble components have dissolved), then put it down and wait a few minutes for the insoluble components to settle to the bottom. 3.4 Open the large detection vial (with the white lid) and set the lid down next to it. Now open the extraction vial again (with the black lid) and look at it carefully. You will notice two distinct sections of liquid, one floating above the other. Using the pipette, you are going to collect liquid from the lower section. First, squeeze the top of the pipette to create a vacuum, then insert it into the vial until the bottom tip of the pipette is in the middle of the lower section of liquid. Now release pressure on the pipette and liquid will be drawn up into it. Be careful not to pick up any deposits or crumbs from the very bottom of the vial. Remove the pipette from the vial. 3.5 Drop two drops from the pipette back into the extraction vial to clear any debris that might have collected in the tip. Then, holding the pipette vertically (straight up and down), add three drops of liquid into the large detection vial. There should be plenty of liquid in the pipette to complete this step, but if it looks like you are going to run out of liquid, get some more by repeating step 3.4 above. Return any leftover liquid inside the pipette back into the extraction vial and put the pipette somewhere safe and out of the way. Then tightly close the lids on both vials. Now pick up and shake the large detection vial several times to mix the ingredients. The color change will begin happening soon and will take 12 minutes to complete. Set a timer. After waiting 12 minutes, you can evaluate the result. See the next section, “EVALUATING THE RESULT,” for details. 4 EVALUATING THE RESULT Follow the instructions above and wait 12 minutes before evaluating the result. Evaluate the result immediately after 12 minutes. Comparing the intensity of the purple color with the enclosed color chart. Follow the instructions below. • Use a white, letter-sized sheet of paper as a background.• In daylight or under bright light, hold the glass vial next to the color chart about six to eight inches in front of the white sheet of paper and look through the glass vial head on. For best results, your eyes should be fairly close to the vial, but no closer than about six to eight inches.• Now compare the color of the liquid in the vial to the color chart. The color bars on the chart correspond to the amount of MDMA that was in the sample you tested.• If you tested 30 mg of powder or crystal and the color matches the 16 mg color bar, you know that your sample is approximately 50% pure (i.e., it contains 16 mg of MDMA for every 30 mg of powder/crystal.)• If you tested 50 mg from an ecstasy tablet, divide the total weight of the tablet by 50 and then multiply by the result. This will tell you how many milligrams of MDMA were in the original tablet. For example, if your tablet weighed 460 mg, and the result shows 16 mg of MDMA in the 50 mg portion that you tested, you know there was approximately 147.2 mg of MDMA in the original tablet (460 ÷ 50 = 9.2 and 9.2 x 16 = 147.2). IMPORTANT! – If the liquid in the vial does not turn purple, or if it turns a color other than purple, then your sample does not contain MDMA. This likely means you forgot to test your sample with a qualitative test kit first. Even if it turns purple, if you didn’t test it first with a qualitative test kit, you don’t know if it contains MDMA. (It might contain MDA, 6-APB or 5-MAPB instead.) Always use a qualitative test kit first, or buy our Advanced MDMA QTest, which contains two other qualitative tests. 5. STORAGE AND SHELF LIFE It is always best to store any reagents in the refrigerator (35° – 46° F) and out of direct sunlight for the longest shelf life, but the ones in this MDMA kit can be stored at room temperature and should last at least 18 months. 6. WARNINGS • Keep the kit away from children and animals.• When performing the test, wear suitable protective gloves, clothing and face/eye protection. If you wear contact lenses, remove them before using the test kit.• Perform the test outdoors or in a well-ventilated area and avoid inhaling the fumes, which can cause dizziness.• The liquids contained in the test kit consist of various acids which may cause a corrosive/irritating effect on the skin or severe eye damage/irritation. Avoid contact with the skin, eyes, mouth or clothing.• Should contact with the above listed areas occur, remove the relevant clothing immediately. Instantly rinse the affected skin areas with water for several minutes. In case of contact with the eyes, immediately rinse them with water for several minutes using both hands to keep the upper and lower eyelids open.• Substances processed with the test kit are not to be consumed! 7. DISCLAIMERS • QTests are only to be used for the detection and quantification of unknown substances.• The result may not be 100% accurate. Your sample could be adulterated with one or more unknown substances that cross-react with the reagents, affecting the quantitative result.• The result does not mean your sample is safe to consume. It could still contain unwanted substances and impurities that can be harmful or even deadly.• The MDMA QTest is not a substitute for laboratory analysis.• miraculix and/or Qtests.org assume no responsibility for the use or misuse of the test kit or the results. 8. DISPOSAL OF MATERIALS Check your local regulations for proper disposal of acids.
$35.06
Media Bros -CRY+ FILTER MEDIA
Media Bros -CRY+ FILTER MEDIA CRY+ is our largest granule size. With a mesh size of 16-x30, this media allows operators to run high-flow processes while maintaining a consistent quality output. DESCRIPTION: CRY+™ Filtration Media: High-Flow, High-Efficiency Filtration CRY+™ is our premium filtration media, designed with a larger granule size (16-30 mesh) to deliver unmatched flow rates without compromising the quality of your extraction. Whether you're processing high volumes or working with challenging biomass, CRY+™ ensures consistent, effective results in every run. Engineered for operators who demand speed and precision, CRY+™ is ideal for high-flow processes where residence time and color remediation are key. With a recommended solvent ratio of 6:1 to 10:1 and the ability to operate at room temperature or below -10°C without clogging, CRY+™ offers flexibility and efficiency for modern extraction setups. Key Features: Larger Granule Size (16-30 mesh): Delivers faster flow rates while maintaining purification performance. Needle Valve Recommended: Fine-tune flow rates for optimal color correction, especially when processing dark or oxidized material. Temperature Resilience: Performs optimally at sub-zero temperatures without clogging. Technical Specs: Use a 4-6” diameter CRC column for best results. Recommended operating pressure: 20-45 psi. Media ratio: 200-300g per 1 lb of biomass. Available Exclusively Through Our Dealer NetworkFind a dealer near you to purchase CRY+™: *A needle valve is recommended on the output (bottom) of the filtration column to properly fine-tune your flow rates. If you are processing dark or oxidized material, a tighter flow restriction will increase residence time, allowing for better color correction. TECHNICAL SPECS Solvent Type Hydrocarbon Color Remediation Level Moderately Heavy/High Pesticide Remediation Level Medium Selectivity/Polarity Level Moderately Selective/Medium Polarity Heavy Metal Remediation Yes Moisture Remediation Level Moderate Fats/Lipids/Waxes Level Medium Crystal Growth Fast Depth Filtration No Flow Rate High Flow pH Level Neutral (pH 7) Best For Fresh Frozen, Nugs, High Quality Suitable for Reruns Yes Distillation Clean-up Moderate Scrub SDS
$126.46 - $1,264.57
Media Bros CR2 Filter Media
CR2 Filter Media Achieving optimal results in supercritical (CO2) extraction requires superior filter media. Enter CR2™ inline filter media. DESCRIPTION Achieving optimal results in supercritical (CO2) extraction requires superior filter media. Enter CR2™ inline filter media. Designed specifically for CO2 extraction, CR2™ is a non-toxic, non-reactive blend of naturally occurring zeolites. Its unique formulation gives it a high adsorption capacity, effectively removing undesirables in CO2 extracts. Like CRX™, CR2™ Filter Media is also designed to handle high flow rates. It exhibits full particle retention even under the demanding high psi conditions present in CO2 extraction. This feature ensures that your CO2 extraction process runs efficiently without compromising the quality of the extract. One common complaint about CO2-extracted products is the so-called "CO2 taste," which can be off-putting for consumers. CR2™ Filter Media tackles this issue head-on, eliminating this bitter taste and ensuring that the final product has greater purity, aesthetic appeal, and consistency. The effect of CR2™ Filter Media on the ‘CO2 taste’ in extracted products can be a game-changer for product quality and consumer satisfaction. All extractors hate baking their filter media or cleaning out caked-on media from their equipment. CR2™ Filter Media does not clog or damage CO2 systems, ensuring smooth operation and longevity of your extraction setup. It was designed by CO2 extraction operators for CO2 operators, so you can focus on extraction rather than worrying about handling issues. Like all of our premium filter media, CR2™ is non-toxic and non-reactive. Nobody should have to wear a HAZMAT suit during CO2 extraction. Using basic safety procedures, our media is organic, natural, and safe to handle. We understand that different operations have different needs, so we provide CR2™ Filter Media in various packages: a 2.5 kg pouch, an 18 kg bucket, and a 200 kg drum. Whether you run a small-scale operation or a large extraction facility, there is a packaging option to suit your needs. FDA GRAS Approved 100% Natural TECHNICAL SPECS Solvent Type CO2 Color Remediation Level Moderately Heavy/High Pesticide Remediation Level Low Selectivity/Polarity Level Moderately Selective/Medium Polarity Heavy Metal Remediation Yes Moisture Remediation Level Low Fats/Lipids/Waxes Level Low Crystal Growth Fast Depth Filtration No Flow Rate High Flow pH Level Neutral (pH 7) Best For Slightly Aged Biomass, Medium Quality Suitable for Reruns No Distillation Clean-up Moderate Scrub
$42.15 - $2,810.15
Media Bros CR41™
CR41™ FILTER MEDIA FOR BHO EXTRACTION CR41 is a perfect blend of our Zeolites and GCRAC, best suited for older oxidized biomass lots and light pesticide/environmental contaminants. PH 7 Description CR41™ is a pH-neutral, fast-flowing, high-performing, multipurpose blend. It helps refine color, remove pesticides, and purify your product. It is blended, prepared, and ready for inline CRC applications. Packaged in: 1.5 kg pouch, 10 kg bucket, and 100 kg drum FDA GRAS Approved 100% Natural TECHNICAL SPECS Solvent Type Hydrocarbon Color Remediation Level Heavy/High Pesticide Remediation Level Medium Selectivity/Polarity Level Moderately Selective/Medium Polarity Heavy Metal Remediation Yes Moisture Remediation Level Low Fats/Lipids/Waxes Level Medium Crystal Growth Fast Depth Filtration No Flow Rate High Flow pH Level Neutral (pH 7) Best For Older Biomass, Low Quality Suitable for Reruns Yes Distillation Clean-up High Scrub
$77.28 - $3,512.69
Media Bros CRAC Filter Media
COLOR REMEDIATION ACTIVATED CARBON (CRAC) FOR ETHANOL EXTRACTION Our powdered version of the G-CRAC, CRAC, is a highly modified bituminous coal carbon with increased surface area. CRAC is unique because it concentrates reactants via adsorption and then promotes their reaction on the pore's surface, which is best suited for heavy environmental clean-up. PH 7 DESCRIPTION Color Remediation Activated Carbon (CRAC) is a top-shelf carbon powder that has revolutionized extraction. Its high-performance selectivity sets it apart from other filter media and is crucial in producing a high-quality extract free of undesirables and impurities. CRAC stands out due to its meticulous preparation process. Its granular consistency makes it easy to handle and is thoroughly sifted, which minimizes the risk of carbon or dust contamination. This commitment to quality creates a safer, cleaner work environment. CRAC is also environmentally friendly; it's non-toxic, biodegradable, and recyclable. This added layer of safety doesn't compromise its effectiveness; instead, it ensures the integrity of the end product and the health of your workforce. CRAC is pH-neutral double activated, which maximizes the carbon's surface potential, allowing for more efficient adsorption and color remediation. By opting for CRAC, you are choosing a product that has been fine-tuned to deliver the best possible extraction results. CRAC stands out not just for what it contains but also for what it doesn't. CRAC delivers all the microporous, mesoporous, and macroporous media you can handle, providing comprehensive remediation of ethanol extract and oil purity you can count on. At Media Bros, we understand the diverse needs of various operations. Hence, CRAC is available in a 1.5 kg pouch, a 4 kg package, a 10 kg bucket, and a 100 kg drum. Regardless of your operation's size, there is a bag of CRAC tailored to your needs. Wine, cheese, peanut butter, jelly, CRAC, and Activated Alumina. The combination of CRAC and Activated Alumina as a filter bed provides a practical and robust solution for ethanol extraction, creating a superior filter blend that enhances the overall remediation process. NSF Certified Use Media Bros Activated Alumina as an alumina media filter bed for best results. TECHNICAL SPECS Solvent Type Hydrocarbon + Ethanol Color Remediation Level Heavy/High Pesticide Remediation Level High Selectivity/Polarity Level Less Selective/Most Polar Heavy Metal Remediation Yes Moisture Remediation Level Low Fats/Lipids/Waxes Level Medium Crystal Growth Fast Depth Filtration No Flow Rate Low Flow pH Level Neutral (pH 7) Best For Older Biomass, Low Quality Suitable for Reruns Yes Distillation Clean-up High Scrub
$105.38 - $5,901.31
Media Bros CRX™ *Compares to BVV Ultra Clear
CRX™ FILTER MEDIA FOR BHO EXTRACTION (NON-REACTIVE) CRX™ Filter Media is a groundbreaking product widely considered the gold standard in filtration media for inline cannabis hydrocarbon extraction. It stands out against the competition as a non-reactive, customizable filter media specifically designed for high-flow extraction applications. This is Media Bros’ best-selling media. Like its high-flow counterparts, CRY™ and CR41™, CRX™ delivers inline hydrocarbon filtration at a flow rate that allows operators to manipulate outflow through a needle valve or flow controller. This enables techs to deliver a fully customizable process that helps maximize efficiency and provides full control over the final product. But where CRX™ really stands out from the rest of Media Bros' premium hydrocarbon extraction line is its “perfect scrub.” CRX™ is designed to preserve the original essence of the biomass, including full terpene and cannabinoid retention profiles, throughout the filtration stage. The blend is perfectly balanced, which is why we recommend it for high-quality biomass; CRX™ preserves the natural chemical compounds of the biomass while delivering a perfect, consistent final extract every time. All of Media Bros’ line of premium products are granular in size for easy handling and do not require baking, which saves time and space in the lab. CRX™ is organically derived and is FDA GRAS-approved, meaning you could eat it if you wanted to (you probably don’t want to). Extraction labs come in all shapes and sizes, and so does our filter media. CRX™ is packaged conveniently in a 1.5 kg pouch, a 10 kg bucket, and a 100 kg drum. Whether you are running a small-scale operation or a large industrial process, there's a packaging option to suit your specific needs. KEY FEATURES High-Flow Rate: Designed to work seamlessly with inline hydrocarbon extraction, its flow rate allows easy manipulation using a needle valve or flow controller. Perfect Scrub: CRX™ is specifically formulated to preserve the full spectrum of terpenes and cannabinoids, ensuring a flawless, consistent final product. User-Friendly: Granular in size for effortless handling, CRX™ is also oven-free, saving both time and lab space. Safety and Compliance: 100% natural, organically derived and FDA GRAS-approved, CRX™ meets the highest safety standards. TECHNICAL SPECS Solvent Type Hydrocarbon Color Remediation Level Average/Moderate Pesticide Remediation Level Low Selectivity/Polarity Level Moderately Selective/Medium Polarity Heavy Metal Remediation No Moisture Remediation Level Low Fats/Lipids/Waxes Level Medium Crystal Growth Fast Depth Filtration No Flow Rate High Flow pH Level Neutral (pH 7) Best For Fresh Frozen, Nugs, High Quality Suitable for Reruns No Distillation Clean-up Low Scrub Sizes Available: 1.5KG SAMPLE 10KG 5 Gallon Bucket 100KG 55 Gallon Cardboard Drum 1000KG Super Sack (Requires forklift or Pallet Jack) Note: Bulk Bags and Bulk sizes are non-stocked items and will be ordered as needed and carry a several week lead time and require a forklift or pallet jack
$42.15 - $2,248.12
Media Bros CRY™
CRY™ FILTER MEDIA FOR BHO EXTRACTION (NON-REACTIVE) CRY™ is a more aggressive variant of our flagship CRX™, but with the same high flow, controllable process. CRY™ is slightly more selective, with about 1.5X the embedded silica content compared to CRX™. This allows CRY™ to filter a wider range of compounds, targeting heavy metals specifically. It is the perfect scrub for nug run, due to its ability to handle higher moisture content biomass. CRY™ also shines when processing high chlorophyll content material like aged-out biomass. Its increased silica content not only boosts the filtration range but also enhances the overall extraction quality. If you are not quite sure if one would work better for your process, try a blend. Both CRX™ and CRY™ work synergistically, and many extractors blend them together at specific blend ratios, fine-tuning their cannabis remediation processes. Customizing the blend ratio according to your specific needs allows you to exploit the full potential of these filtration powerhouses. Need to know how to do it? We offer support and consulting to help you get the most out of your extract. CRY™ Filter Media is packaged conveniently in a 1.5 kg pouch, a 10 kg bucket, and a 100 kg drum. These varied packaging options cater to operations of different scales, from small businesses to large-scale industrial processes. The best extracts in the world are made with Media Bros. FDA GRAS Approved 100% Natural TECHNICAL SPECS Solvent Type Hydrocarbon Color Remediation Level Moderately Heavy/High Pesticide Remediation Level Medium Selectivity/Polarity Level Moderately Selective/Medium Polarity Heavy Metal Remediation Yes Moisture Remediation Level Moderate Fats/Lipids/Waxes Level Medium Crystal Growth Fast Depth Filtration No Flow Rate High Flow pH Level Neutral (pH 7) Best For Fresh Frozen, Nugs, High Quality Suitable for Reruns Yes Distillation Clean-up Moderate Scrub Sizes Available: 1.5KG SAMPLE 10KG 5 Gallon Bucket 100KG 55 Gallon Cardboard Drum 1000KG Super Sack (Requires forklift or Pallet Jack) Note: Bulk Bags and Bulk sizes are non-stocked items and will be ordered as needed and carry a several week lead time and require a forklift or pallet jack
$42.15 - $2,248.12
Media Bros CRY™ MEDIUM FLOW
CRY™ MEDIUM FLOW (CRY-M™) FILTER MEDIA FOR BHO EXTRACTION (NON-REACTIVE) This medium flow non-reactive variant of CRY allows operators to increase operating pressures and surface area for a more fine-tuned process. PH 7 DESCRIPTION CRY™ Medium Flow (CRY-M™) is a finer version of CRY™ designed for systems operating at slightly higher PSIs that still need non-reactive high flow outputs and a little extra selectivity. It is not quite powder, but a much finer grain than CRY. The smaller granule size helps prevent channeling that can sometimes occur at higher PSIs. We recommend CRY-M™ for operators who want the same effect as CRY™ but are running at higher pressures or systems with size limitations. For extracts that require additional remediation beyond CRX-M™, CRY-M™ offers a superior polish, effectively addressing color, fats, and lipids. Opt for CRY-M when aiming for effortlessly reproducible results with older biomass. Suggested use: 150–250g per lb. of biomass Packaged in: 1.5 kg pouch, 5 gallon bucket, and 100 kg drum TECHNICAL SPECS Solvent Type Hydrocarbon Color Remediation Level Moderately Heavy/High Pesticide Remediation Level Medium Selectivity/Polarity Level Moderately Selective/Medium Polarity Heavy Metal Remediation Yes Moisture Remediation Level Moderate Fats/Lipids/Waxes Level Medium Crystal Growth Fast Depth Filtration No Flow Rate Moderate Flow pH Level Neutral (pH 7) Best For Slightly Aged Biomass, Medium Quality Suitable for Reruns Yes Distillation Clean-up Moderate Scrub SDS
$42.15 - $2,248.12
Media Bros K-CRAC Filter Media
KLEANUP COLOR REMEDIATION ACTIVATED CARBON "Kleanup" Color Remediation Activated Carbon (K-CRAC) is a highly versatile, non-toxic, food-grade post-processing activated carbon powder designed to enhance the purification process of cannabis oil. DESCRIPTION "Kleanup" Color Remediation Activated Carbon (K-CRAC) is a highly versatile, non-toxic, food-grade post-processing activated carbon powder designed to enhance oil purification. K-CRAC boasts a high-surface-area activated carbon powder that provides top-notch purification capabilities. It effectively removes undesirable compounds and impurities from oil during post-processing. K-CRAC is specifically formulated to clean up the full-color body of oil, improving its appearance and quality. K-CRAC is best used with hydrocarbons due to its polarity. Packaged in: 1.5 kg pouch and 10 kg bucket. Use Media Bros Activated Activated Alumina as an alumina media filter bed for best results.
$140.51 - $8,430.45
Media Bros Medium flow CRX-M
Media Bros Medium flow CRX This non-reactive medium flow variant allows operators to increase operating pressures and surface area for a more fine-tuned process. PH 7 Description: Introducing CRX Medium Flow™ (CRX-M™), a not-quite-powder/fine-grain premium filter media formulated for non-reactive, high flow and high-pressure hydrocarbon extraction. Its texture is designed to replace traditional powdered media like B80 without channeling and clogging issues commonly encountered with conventional powders. Extractors accustomed to traditional powders like B80 will find that CRX-M™ offers similar flow properties but with the added benefit of superior terpene retention. Like all of our premium blends, CRX-M™ is non-reactive, ensuring it's safe and easy to handle in your lab setting. It eliminates the need for extensive clean-up, saving you time and effort. CRX-M™ has all the benefits of its more granular twin, the flagship CRX™. It is a "perfect scrub" media, ideal for high-quality biomass and nug run processing. You want total control over flow and ensure the terpenes and flavonoids are retained from plant to extracted oil. Extraction labs vary in size, and so does our range of filter media. Our CRX-M™ product is available in three convenient packaging options: a 1.5 kg pouch, a 10 kg bucket, and a 100 kg drum. Whether operating on a small scale or running an extensive industrial process, we have the perfect packaging to meet your needs. Technical Specs: Solvent Type Hydrocarbon Color Remediation Level Average/Moderate Pesticide Remediation Level Low Selectivity/Polarity Level Moderately Selective/Medium Polarity Heavy Metal Remediation No Moisture Remediation Level Low Fats/Lipids/Waxes Level Medium Crystal Growth Fast Depth Filtration No Flow Rate Moderate Flow pH Level Neutral (pH 7) Best For Fresh Frozen, Nugs, High Quality Suitable for Reruns No Distillation Clean-up Low Scrub SOP SDS Before you get started, please remember this: As CRX™ and CRY™ are not powders designed not to absorb moisture before use, no baking or preparation is needed. For optimal success, ensure your flow is gentle and consistent. RATIOS Solvent to Biomass: ratios range from 6:1 to 10:1, depending on the quality of the plant matter you are distilling—lower ratios for top-tier biomass and higher ratios for older or lower-quality biomass. Media to Biomass: Load 150 - 250 grams of filter media into filtration housing for every 1 lb of biomass. The media quantity used is dependent on the quality of the biomass. Higher-quality biomass requires less media. Lower-quality biomass requires more media. The lookup table can be used as a reference, but because every kind of plant matter is different, you will need to experiment a little bit to achieve the best results. That said, this chart is an excellent baseline from which to start. TEMPS To ensure optimal performance, keep the temperature at -10°C or below while using the media. Our media is designed to prevent clogging. FLOW When transferring from the biomass vessel to the recovery vessel, maintain a maximum flow rate of 1 GPM. Our media performs best with a consistent and gentle flow. To prevent channeling, avoid sudden hydraulic surges through the CRC column. A shower or initial fill of the column is highly recommended for optimal results. YIELD Any lost yield can be fully recovered by flushing the media with solvent. Most users report achieving substantial yield gains by maintaining high solvent-to-biomass ratios or flushing our media after an extraction transfer.
$42.15 - $2,248.12
METAGLAS® Tri-Clamp Sight Glass
METAGLAS Tri-Clamp/ Tri Clover Sight Glass ***NOTICE TO CUSTOMER: ONLY CONTAINS 1 SIGHT GLASS. Please increase quantity if you want more.*** Data Sheet Metaglas Line Operating and Maintenance Instructions The strongest, most secure sight glass available, Metaglas mechanically prestressed windows, are available in a sanitary clamp design, MetaClamp, for ports and light ports in processing applications or inline visual flow indicators. Application: Sanitary MetaClamps to fit sanitary clamp connections. With simple and fast installation with no risk of breakage, this sleek, compact, one-piece design provides a cleaner look, less bateria traps and unsurpassed safety. The MetaClamp sight glass can be used as a view port mounted on a ferrule, a “cross” for inline visual flow indication or as a light port. Many other connection types are also available, as shown on the reverse side. Materials available include 2205 Duplex Stainless Steel, Hastelloy®, Monel® and Inconel®. Approvals and Technical Data: - USP Class VI (tested to confirm biocompatibility) - BPE Compliant and TÜV Approved - Sight glass fused to metal conforming to DIN7079 - Borosilicate glass to USP Type I and DIN7080 - Standard surface finish of 10 Ra µ-in (0.25µm) - Material to ASTM/ASME, TÜV and DIN/EN standards - Certificate of Conformity to EN 10204-3.1B or 3.1A - Pressure Equipment Directive 97/23/EG How Metaglas® Works: Metaglas provides a level of safety and a useful service life, well beyond that provided by conventional tempered glass or plastic used as sight glass windows. Even in the most extreme temperature (to 572ºF using Hastelloy) or overpressure situations, sudden, total failure essentially never occurs. Patented Metaglas windows are formed by melting borosilicate glass into a precisely formed metal ring. As the glass cools, it solidifies, preventing the metal ring from contracting back to its theoretical size. The result is a uniform, mechanically prestressed fusion of glass and metal that combines excellent optical characteristics with greatly enhanced physical characteristics. Vital in sanitary service, the Metaglas discs have an uninterrupted surface with no crevice to trap bacteria - no epoxies, resins, or glue - a true fusion. The standard surface finish is 10 Ra µ-in (0.25 Ra µm). Electopolishing available upon request.
$646.33 - $681.46
Methanol 99% Lab Grade
BVV™ High Purity Lab Grade Methanol (Note: Container style and color may vary) Spigots/Faucets are only compatible with 5 Gallon Plastic Jugs and must be purchased separately BVV™ High Purity Lab Grade Methanol is used to remove and extract terpenes, tannins, alkaloids, glycosides, lignans, and terpinoids from plants. It is used to extract bio-active, phenolic and polar compounds from medicinal plants. Methanol is a high purity solvent used to manufacture botanical solutions and is easily evaporated. Methanol is used in research and testing laboratories for phytochemical study, phytochemical analysis and chemical synthesis. Methanol is used to prepare methanol/water/acetic acid mixtures. BVV™ Methanol SDS BVV™ Methanol COA Chemical Formula: CH3OH Molecular Weight: 32.042 g·mol−1 CAS Registry Number: 67-56-1 Appearance Colorless Liquid Odor: Faint and similar to ethanol Density 0.792 g/cm3 Boiling Point: 64.7 °C /148.5 °F Solubility in water: miscible GHS Pictograms: GHS Signal Word: Danger GHS Hazard Statements: H225, H301, H302, H305, H311, H331, H370 GHS Precautionary Statements P210, P233, P235, P240, P241, P242, P243, P260, P264, P270, P271, P280, P301+P330+P331, P302+P352, P303+P361+P353, P304+P340, P305+P351+P338, P307+P311, P310, P311, P312, P337+P313, P361, P363, P370+P378, P403+P233, P405, P501 UN Identification Number: 1230 Proper Shipping Name: Methanol Transport Hazard Class: 3 Packing Group: II DOT Placard: What Is Methanol? Methanol, also known as methyl alcohol or wood alcohol, is a type of alcohol with the chemical formula CH3OH. It is the simplest alcohol, consisting of a methyl group (CH3) linked to a hydroxyl group (OH). Methanol is a colorless, flammable liquid with a slightly sweet odor. It is commonly used as an industrial solvent, antifreeze, fuel, and as a feedstock in the production of chemicals, plastics, and synthetic materials. Methanol can be synthesized from various sources, including natural gas, carbon monoxide, and biomass. It is considered a hazardous substance due to its toxicity when ingested, inhaled, or absorbed through the skin. Methanol is also used as an industrial and laboratory solvent and as a fuel in some types of racing cars and model engines. One important thing to note is that methanol is highly toxic when consumed, and even small amounts can be lethal. It should never be ingested, and safety precautions should be taken when handling this substance. What Is Methanol Used For? Methanol is used for a wide range of industrial, commercial, and laboratory applications. Some of its common uses include: Fuel: Methanol is used as an alternative fuel in some types of vehicles, particularly racing cars and model engines. It is also used in the production of biodiesel and as a fuel additive. Solvent: Methanol is a versatile solvent that can dissolve a variety of substances, making it useful in industries such as paint, varnish, and ink production. It is also used as a cleaning agent in laboratories and industrial settings. Antifreeze: Methanol is an essential component of some antifreeze formulations, where it helps prevent the freezing of engine coolant in cold temperatures. Chemical Intermediate: Methanol serves as a key building block in the production of various chemicals and materials, including formaldehyde, acetic acid, methyl methacrylate (used in plastics and coatings), and more. Fuel Cell Feedstock: Methanol can be used as a feedstock for the production of hydrogen, which can be used in fuel cells for electricity generation and other applications. Preservative: In the pharmaceutical and personal care industries, methanol is used as a preservative in some products. Denaturant: Methanol is added to industrial ethanol to make it unfit for consumption (denatured). This ensures that the ethanol cannot be used for drinking purposes and is used for industrial applications. Laboratory Reagent: Methanol is commonly used in laboratories as a reagent and solvent for various chemical experiments and analyses. Extraction: It is used in some extraction processes, such as the extraction of essential oils from plants. Energy Storage: Methanol is being explored as a potential energy carrier for energy storage and transportation, particularly in the form of methanol fuel cells. It's important to note that methanol is toxic to humans and should be handled with care. Ingesting or inhaling methanol vapors can be extremely dangerous and potentially fatal. Proper safety precautions and handling procedures are necessary when working with methanol. What Is The Structure of Methanol? Methanol, also known as methyl alcohol, has a simple chemical structure. Its molecular formula is CH3OH, which represents one carbon (C) atom, four hydrogen (H) atoms, and one oxygen (O) atom bonded together. Here's the structural formula of methanol: In this structure: The central carbon atom (C) is bonded to three hydrogen atoms (H) and one oxygen atom (O). The oxygen atom is bonded to the carbon atom through a single covalent bond (C-O). The remaining three hydrogen atoms are bonded to the carbon atom, completing its four covalent bonds. Methanol is a polar molecule due to the electronegativity difference between oxygen and hydrogen atoms, which results in a partial positive charge on the hydrogen atoms and a partial negative charge on the oxygen atom. This polarity gives methanol its unique chemical properties and makes it a versatile solvent in various applications. What are the Hazards of Methanol? Methanol, while commonly used in various industrial and laboratory applications, poses several hazards, primarily due to its toxic and flammable nature. Here are some of the hazards associated with methanol: Toxicity: Methanol is highly toxic to humans when ingested, inhaled, or absorbed through the skin. The toxic effects are primarily due to its metabolites, formaldehyde, and formic acid. Methanol poisoning can lead to symptoms such as headache, dizziness, nausea, vomiting, abdominal pain, and in severe cases, it can cause blindness, organ failure, and death. Flammability: Methanol is flammable and can form explosive mixtures in the air when its vapor concentration is within certain limits. It has a relatively low flashpoint, making it susceptible to ignition by heat, sparks, or open flames. Proper storage and handling precautions are essential to prevent fire hazards. Irritant: Methanol can be irritating to the eyes, skin, and respiratory tract. Contact with methanol vapor or liquid can lead to skin irritation, redness, and chemical burns. Inhaling methanol vapor can irritate the respiratory system and cause coughing and throat irritation. Environmental Impact: Methanol is harmful to the environment. Spills or releases of methanol can contaminate soil and water, posing a risk to aquatic life and ecosystems. It is important to handle and dispose of methanol responsibly to minimize its environmental impact. Incompatibility: Methanol should not be stored or transported in containers or systems that have previously held incompatible materials, as it can react with some substances and form hazardous compounds. Cumulative Exposure: Prolonged or repeated exposure to methanol vapor or mist over time can result in cumulative health effects, particularly on the central nervous system and the optic nerve. Ingestion Risk: Methanol has a sweet taste and is sometimes mistaken for ethanol (the alcohol found in alcoholic beverages). Accidental ingestion of methanol can occur, especially if it is stored in containers that are not clearly labeled. To safely handle methanol and mitigate these hazards, it is crucial to follow strict safety protocols, use appropriate personal protective equipment (PPE), store methanol in well-ventilated areas away from open flames, and provide proper training to personnel working with methanol. Emergency response plans and first-aid measures for methanol exposure should also be in place in case of accidents or spills. How Do I Use Methanol Safely? Using methanol safely is essential due to its toxic and flammable nature. Whether you're working with methanol in a laboratory, industrial setting, or other applications, here are some guidelines for safe handling: Personal Protective Equipment (PPE): Always wear appropriate PPE, including safety goggles, chemical-resistant gloves, a lab coat or chemical-resistant apron, and closed-toe shoes. Consider additional protective gear, such as a face shield, when handling large quantities or performing high-risk operations. Storage: Store methanol in well-ventilated areas away from heat sources, open flames, and direct sunlight. Use containers made of materials compatible with methanol, such as glass or approved plastic containers. Label containers clearly with the contents. Ensure proper labeling and hazard signage in storage areas. Handling: Handle methanol in a fume hood or well-ventilated workspace to minimize inhalation exposure. Do not use methanol near open flames, sparks, or heat sources. Avoid skin contact; wear gloves and lab coats to prevent skin exposure. Use a face shield or safety goggles to protect your eyes. Spill Response: Have spill kits and absorbent materials (e.g., spill pads, spill pillows) available for immediate use. In the event of a spill, ventilate the area, and contain the spill to prevent it from spreading. Wear appropriate PPE when cleaning up spills. Follow your workplace's spill response procedures and dispose of contaminated materials properly. Storage and Dispensing: Use safety containers designed for methanol when dispensing or transferring the liquid. Never use glassware or containers that have been used for other chemicals without thorough cleaning. Ensure proper grounding and bonding when transferring methanol to prevent static electricity buildup. Inhalation Exposure: Minimize inhalation exposure by working in a well-ventilated area or under a fume hood. If you suspect inhalation exposure, move to an area with fresh air and seek medical attention if symptoms persist. Ingestion Prevention: Do not eat, drink, or smoke in areas where methanol is handled. Avoid using containers or equipment that may be contaminated with methanol for food or beverage storage. Fire Safety: Methanol is flammable; keep it away from open flames, sparks, and heat sources. Use explosion-proof electrical equipment in areas where methanol vapors may be present. Emergency Response: Familiarize yourself with the location of safety showers, eyewash stations, fire extinguishers, and emergency exits. Know the location of first-aid supplies and procedures for methanol exposure. Training and Education: Ensure that personnel handling methanol are properly trained in its safe handling, storage, and emergency response procedures. Waste Disposal: Dispose of methanol waste in accordance with local, state, and federal regulations for hazardous waste disposal. Always follow your workplace's safety protocols and consult with safety officers or supervisors for specific safety procedures related to methanol handling in your environment. Regular safety training and awareness are essential to prevent accidents and protect your health when working with methanol.
$23.89 - $2,177.87
Methanol ACS (Reagent)
ACS Reagent Grade Methanol (Note: Container style and color may vary) BVV™ High ACS Reagent Grade Methanol is the highest grade. ACS Reagent stands out for its exceptional purity and meets the strictest standards used by the American Chemical Society (ACS). This is an excellent solvent for uses in laboratory and analytical applications. Methanol ACS Reagent Grade meets rigorous ACS specifications, ensuring reliability and reproducibility in analytical and research applications. Methanol is a high purity solvent used to manufacture botanical solutions and is easily evaporated. Methanol is used in research and testing laboratories for phytochemical study, phytochemical analysis and chemical synthesis. Methanol is used to prepare methanol/water/acetic acid mixtures, and is completely soluble in water. Spigots/Faucets are only compatible with 5 Gallon Plastic Jugs and must be purchased separately Trigger Sprayer is only compatible with 1QT and 1 Gallon sizes Chemical Formula: CH3OH Molecular Weight: 32.042 g·mol−1 CAS Registry Number: 67-56-1 Appearance Colorless Liquid Odor: Faint and similar to ethanol Density 0.792 g/cm3 Boiling Point: 64.7 °C /148.5 °F Solubility in water: miscible GHS Pictograms: GHS Signal Word: Danger GHS Hazard Statements: H225, H301, H302, H305, H311, H331, H370 GHS Precautionary Statements P210, P233, P235, P240, P241, P242, P243, P260, P264, P270, P271, P280, P301+P330+P331, P302+P352, P303+P361+P353, P304+P340, P305+P351+P338, P307+P311, P310, P311, P312, P337+P313, P361, P363, P370+P378, P403+P233, P405, P501 UN Identification Number: 1230 Proper Shipping Name: Methanol Transport Hazard Class: 3 Packing Group: II DOT Placard: What Is Methanol? Methanol, also known as methyl alcohol or wood alcohol, is a type of alcohol with the chemical formula CH3OH. It is the simplest alcohol, consisting of a methyl group (CH3) linked to a hydroxyl group (OH). Methanol is a colorless, flammable liquid with a slightly sweet odor. It is commonly used as an industrial solvent, antifreeze, fuel, and as a feedstock in the production of chemicals, plastics, and synthetic materials. Methanol can be synthesized from various sources, including natural gas, carbon monoxide, and biomass. It is considered a hazardous substance due to its toxicity when ingested, inhaled, or absorbed through the skin. Methanol is also used as an industrial and laboratory solvent and as a fuel in some types of racing cars and model engines. One important thing to note is that methanol is highly toxic when consumed, and even small amounts can be lethal. It should never be ingested, and safety precautions should be taken when handling this substance. What Is Methanol Used For? Methanol is used for a wide range of industrial, commercial, and laboratory applications. Some of its common uses include: Fuel: Methanol is used as an alternative fuel in some types of vehicles, particularly racing cars and model engines. It is also used in the production of biodiesel and as a fuel additive. Solvent: Methanol is a versatile solvent that can dissolve a variety of substances, making it useful in industries such as paint, varnish, and ink production. It is also used as a cleaning agent in laboratories and industrial settings. Antifreeze: Methanol is an essential component of some antifreeze formulations, where it helps prevent the freezing of engine coolant in cold temperatures. Chemical Intermediate: Methanol serves as a key building block in the production of various chemicals and materials, including formaldehyde, acetic acid, methyl methacrylate (used in plastics and coatings), and more. Fuel Cell Feedstock: Methanol can be used as a feedstock for the production of hydrogen, which can be used in fuel cells for electricity generation and other applications. Preservative: In the pharmaceutical and personal care industries, methanol is used as a preservative in some products. Denaturant: Methanol is added to industrial ethanol to make it unfit for consumption (denatured). This ensures that the ethanol cannot be used for drinking purposes and is used for industrial applications. Laboratory Reagent: Methanol is commonly used in laboratories as a reagent and solvent for various chemical experiments and analyses. Extraction: It is used in some extraction processes, such as the extraction of essential oils from plants. Energy Storage: Methanol is being explored as a potential energy carrier for energy storage and transportation, particularly in the form of methanol fuel cells. It's important to note that methanol is toxic to humans and should be handled with care. Ingesting or inhaling methanol vapors can be extremely dangerous and potentially fatal. Proper safety precautions and handling procedures are necessary when working with methanol. What Is The Structure of Methanol? Methanol, also known as methyl alcohol, has a simple chemical structure. Its molecular formula is CH3OH, which represents one carbon (C) atom, four hydrogen (H) atoms, and one oxygen (O) atom bonded together. Here's the structural formula of methanol: In this structure: The central carbon atom (C) is bonded to three hydrogen atoms (H) and one oxygen atom (O). The oxygen atom is bonded to the carbon atom through a single covalent bond (C-O). The remaining three hydrogen atoms are bonded to the carbon atom, completing its four covalent bonds. Methanol is a polar molecule due to the electronegativity difference between oxygen and hydrogen atoms, which results in a partial positive charge on the hydrogen atoms and a partial negative charge on the oxygen atom. This polarity gives methanol its unique chemical properties and makes it a versatile solvent in various applications. What are the Hazards of Methanol? Methanol, while commonly used in various industrial and laboratory applications, poses several hazards, primarily due to its toxic and flammable nature. Here are some of the hazards associated with methanol: Toxicity: Methanol is highly toxic to humans when ingested, inhaled, or absorbed through the skin. The toxic effects are primarily due to its metabolites, formaldehyde, and formic acid. Methanol poisoning can lead to symptoms such as headache, dizziness, nausea, vomiting, abdominal pain, and in severe cases, it can cause blindness, organ failure, and death. Flammability: Methanol is flammable and can form explosive mixtures in the air when its vapor concentration is within certain limits. It has a relatively low flashpoint, making it susceptible to ignition by heat, sparks, or open flames. Proper storage and handling precautions are essential to prevent fire hazards. Irritant: Methanol can be irritating to the eyes, skin, and respiratory tract. Contact with methanol vapor or liquid can lead to skin irritation, redness, and chemical burns. Inhaling methanol vapor can irritate the respiratory system and cause coughing and throat irritation. Environmental Impact: Methanol is harmful to the environment. Spills or releases of methanol can contaminate soil and water, posing a risk to aquatic life and ecosystems. It is important to handle and dispose of methanol responsibly to minimize its environmental impact. Incompatibility: Methanol should not be stored or transported in containers or systems that have previously held incompatible materials, as it can react with some substances and form hazardous compounds. Cumulative Exposure: Prolonged or repeated exposure to methanol vapor or mist over time can result in cumulative health effects, particularly on the central nervous system and the optic nerve. Ingestion Risk: Methanol has a sweet taste and is sometimes mistaken for ethanol (the alcohol found in alcoholic beverages). Accidental ingestion of methanol can occur, especially if it is stored in containers that are not clearly labeled. To safely handle methanol and mitigate these hazards, it is crucial to follow strict safety protocols, use appropriate personal protective equipment (PPE), store methanol in well-ventilated areas away from open flames, and provide proper training to personnel working with methanol. Emergency response plans and first-aid measures for methanol exposure should also be in place in case of accidents or spills. How Do I Use Methanol Safely? Using methanol safely is essential due to its toxic and flammable nature. Whether you're working with methanol in a laboratory, industrial setting, or other applications, here are some guidelines for safe handling: Personal Protective Equipment (PPE): Always wear appropriate PPE, including safety goggles, chemical-resistant gloves, a lab coat or chemical-resistant apron, and closed-toe shoes. Consider additional protective gear, such as a face shield, when handling large quantities or performing high-risk operations. Storage: Store methanol in well-ventilated areas away from heat sources, open flames, and direct sunlight. Use containers made of materials compatible with methanol, such as glass or approved plastic containers. Label containers clearly with the contents. Ensure proper labeling and hazard signage in storage areas. Handling: Handle methanol in a fume hood or well-ventilated workspace to minimize inhalation exposure. Do not use methanol near open flames, sparks, or heat sources. Avoid skin contact; wear gloves and lab coats to prevent skin exposure. Use a face shield or safety goggles to protect your eyes. Spill Response: Have spill kits and absorbent materials (e.g., spill pads, spill pillows) available for immediate use. In the event of a spill, ventilate the area, and contain the spill to prevent it from spreading. Wear appropriate PPE when cleaning up spills. Follow your workplace's spill response procedures and dispose of contaminated materials properly. Storage and Dispensing: Use safety containers designed for methanol when dispensing or transferring the liquid. Never use glassware or containers that have been used for other chemicals without thorough cleaning. Ensure proper grounding and bonding when transferring methanol to prevent static electricity buildup. Inhalation Exposure: Minimize inhalation exposure by working in a well-ventilated area or under a fume hood. If you suspect inhalation exposure, move to an area with fresh air and seek medical attention if symptoms persist. Ingestion Prevention: Do not eat, drink, or smoke in areas where methanol is handled. Avoid using containers or equipment that may be contaminated with methanol for food or beverage storage. Fire Safety: Methanol is flammable; keep it away from open flames, sparks, and heat sources. Use explosion-proof electrical equipment in areas where methanol vapors may be present. Emergency Response: Familiarize yourself with the location of safety showers, eyewash stations, fire extinguishers, and emergency exits. Know the location of first-aid supplies and procedures for methanol exposure. Training and Education: Ensure that personnel handling methanol are properly trained in its safe handling, storage, and emergency response procedures. Waste Disposal: Dispose of methanol waste in accordance with local, state, and federal regulations for hazardous waste disposal. Always follow your workplace's safety protocols and consult with safety officers or supervisors for specific safety procedures related to methanol handling in your environment. Regular safety training and awareness are essential to prevent accidents and protect your health when working with methanol.
$29.51 - $843.04
Methyl Ethyl Ketone (MEK) Lab Grade 99.9%
Methyl Ethyl Ketone (MEK) 99.9% Lab Grade - C4H8O Methyl Ethyl Ketone (MEK), also known as butanone is an organic compound. Its a colorless liquid and has a sweet order similar to acetone. MEK is a widely used in commercial applications and as a solvent, and it dissolves many substances. Our MEK is a very high purity percentage which make it appropriate for use in laboratory and analytical applications. MEK has a flash point 20 °F. Vapors heavier than air. Does not react with water. It is partially soluble in water, and soluble in most other organic solvents. It will float on water while it rapidly dissolves in it MEK goes by a couple of names: 2-Butanone, Butan-2-one, Butanone, Ethyl methyl ketone, Methylethyl ketone Chemical Formula: C4H8O Molecular Weight: 72.1057 CAS Registry Number: 78-93-3 Appearance Colorless Liquid Odor: Mint or acetone-like Density 0.8050 g/ml Boiling Point: 79.64C/175.35F Solubility in water: 27.5g/100ml GHS Pictograms: GHS Signal Word: Danger GHS Hazard Statements: H225, H319, H336 GHS Precautionary Statements P210, P233, P240, P241, P242, P243, P261, P264, P271, P280, P303+P361+P353, P304+P340, P305+P351+P338, P312, P337+P313, P370+P378, P403+P233, P403+P235, P405, P501 UN Identification Number: 1193 Proper Shipping Name: Ethyl Methyl Ketone Transport Hazard Class: 3 Packing Group: II DOT Placard: What is Methyl Ethyl Ketone? Methyl ethyl ketone (MEK), also known as butanone, is a colorless, volatile liquid organic compound with the chemical formulaC4H8O. It is classified as a ketone, characterized by the presence of a carbonyl group (C=O) bonded to two carbon atoms. How Is Methyl Ethyl Ketone Produced? While Methyl Ethyl Ketone is biosynthesized by trees and is found in small quantities in foods such as some fruits and vegetables, chicken, beans, honey, and a wide variety of cheeses, the majority of Methyl Ethyl Ketone is produced using dehydrogenation of secondary butyl alcohol (approximately 86%) and as a byproduct of butane oxidation (remaining 14%). How is Methyl Ethyl Ketone Stored and Distributed? Methyl ethyl ketone is packed in drums. It should be stored in a cool, dry, well-ventilated area that is free from the risk of ignition as it is highly flammable. For transportation purposes, methyl ethyl ketone is classified as packing group II and a hazard class 3 with a flashpoint of -9° C What is Methyly Ethyl Ketone Used For? Methyl Ethyl Ketone is used as a solvent in the manufacturing of adhesives, protective coatings, inks and magnetic tapes. It is also the preferred extraction solvent for dewaxing lube oil. Is Methyl Ethyl Ketone Banned? Methyl ethyl ketone (MEK) is not banned nationally, but it is banned in Southern California and some states with strict VOC laws. What are the dangers of Methyl Ethyl Ketone? The compound is rated a 1 for health under the NFPA 704 indicating that exposure should only cause a minor residual injury. To avoid inhalation occurring, especially for regular uses, adequate ventilation should be ensured with local exhaust ventilation and enclosures. The direct inhalation of high levels of MEK may cause dizziness, nausea, headaches, irritation of the respiratory system and chest tightness. If the individual has difficulty breathing, they should be moved to air free of the vapours and be provided oxygen until medical assistance is available. Direct eye exposure can cause sore, stinging, red eyes with tearing and vapours can also irritate the eyes. Chemical safety goggles should therefore be used when contact with the eyes is possible. Repeated or prolonged skin contact should be avoided as this can cause irritation and dryness. Therefore, gloves, aprons and appropriate boots should be worn when repeated contact with MEK is possible. Methyl Ethyl Ketone (MEK) Lab Grade SDS
$23.89 - $843.04
Micro-Cap Filters
ErtelAlsop Micro-Cap Filters 1 Micron Grade M-503P Diatomaceous Earth Micro-Cap 1 Micron Grade MC-55CP Carbon Filled Micro-cap With single-use technology on the rise, our new ErtelAlsop MicroCap Laboratory Cabinet has been created to simplify filtration and separation trials for research and development, as well as, process development laboratories. This attractive and well organized Cabinet easily stores the filters you require. The MicroCap™ suite of single-use capsules provide a uniquely flexible line of disposable depth filter products designed for optimizing and developing processes during scale-up and scale-down studies. The MicroCap 22 capsule enables quick and efficient determination of appropriate media grades in providing the best filtration performance as well as required filtration area to meet process volumes. Each MicroCap Laboratory Cabinet is supplied with forty-eight MicroCap 22 capsules in twelve different grades ranging from a nominal 15 micron to 0.2 micron. All supplied capsules contain 22.5 cm2 (3.48 in2) of filtration area per capsule. These easy to use capsules allow users to test a comprehensive range of depth filter media and efficiently determine the right solution for their process needs. Applications MicroCap capsules are designed for small volume processing of: Primary separations/prefiltration Secondary clarification Cell culture harvest Cell culture clarification DNA removal Endotoxin reduction Host Cell Protien (HCP) reduction Protein aggregate removal Decolorization Performance The MicroCap Laboratory Cabinet incorporates ErtelAlsop’s MicroCap capsules each containing our high performance XL Series, and select MicroMedia series grades of depth filter media to provide the optimum balance of dirt holding capacity and throughput. Containing a high performance grade of diatomaceous earth filter aid, coupled with a strong positive zeta potential, ErtelAlsop’s XL media capsules provide superior contaminant retention. The XL Series of depth filter media exhibits 2-5 times the throughput of competitive media while maintaining equivalent or better product clarity. Reliability As with all ErtelAlsop depth filter products the MicroCap capsules provide performance consistency and lot to lot traceability all in an easy-to-use format. All MicroCap capsules are batch tested in order to meet all quality requirements and meet all applicable USP requirements including the Class VI Plastics. Scalability The MicroCap series of single-use capsules contain six easily scalable sizes of capsules. Additionally each of these capsules readily scale to ErtelAlsop’s 12” and 16” diameter lenticular depth filter modules.
$14.05 - $21.08
Microbe Life Photosynthesis Plus, 5 gal
Microbe Life Photosynthesis Plus 5 GallonPhotosynthesis Plus by MICROBE Life Hydroponics is a breakthrough in biology and biophysics once thought impossible to achieve. By driving and accelerating the processes that contribute to overall plant vigor, Photosynthesis Plus will accelerate your time to market while improving your plant growth, vigor and yield.Photosynthesis Plus is a novel culture consortium that contains stable microorganisms capable of improving plant conversion of carbon dioxide to available carbon to fuel plant requirements, and drives plant biology at both the foliar level and the root zone.Photosynthesis Plus rapidly establishes essential plant-supporting biology, even in a media void of organisms. Combined with its ability to improve the plants’ own photosynthetic machinery and inhabit the root zone, Photosynthesis Plus will help to accelerate and optimize plant functions.
$325.49
Microbe Life Photosynthesis Plus-O, 5 gal (OR only)
Microbe Life Photosynthesis Plus - 5 Gal. OR OnlyPhotosynthetic bacteria will promote photosynthesis in all plants, unlike endo and ecto fungi which only works on specific species. Enhances plant functions at the foliar level and the root zone in both soil and soilless substrates. Enhances photosynthesis and biological function by allowing plants to capture and utilize radiant energy more efficiently. Speeds uptake and distribution of essential macro- and micronutrients required for all plant metabolic functions and growth. Promotes plant vigor and reduces input costs while increasing yields.Use in addition to ALL nutrient and fertilizer programs for maximum yields!
$455.23$325.49
Microbe Life Plus-C, 1 qt (CA ONLY)
Plus-C- 32oz CA ONLYWhat it is: The culture consortium produced by Ecological Laboratories, Inc. that is used on tens of thousands of acres of crops worldwide is the foundation for our Photosynthesis Plus, a complete ecosystem in the bottle. The proprietary formulation and culture growth enhances product performance via selective adaptation, resulting in superior performance in aerobic, facultative, anaerobic and anoxic environments. Shelf stable for two years. What it does: Enhances plant functions at the foliar level and the root zone in both soil and soilless substrates. Enhances photosynthesis and biological function by allowing plants to capture and utilize radiant energy more efficiently. Speeds uptake and distribution of essential macro- and micronutrients required for all plant metabolic functions and growth. Promotes plant health and reduces input costs while increasing yields. Use in addition to ALL nutrient and fertilizer programs for maximum yields. May be used for indoor and outdoor use with all hydroponic, NFT, drip systems, aeroponic, irrigation and liquid feeding systems, with all soilless media, including coco coir. Compatible with all fertilizer programs. Always check pH and CF levels. Enhances photosynthesis and biological function Speeds uptake and distribution of essential macro- and micronutrients required for all plant metabolic functions and growth Promotes plant health and reduces input costs while increasing yields
$35.06$34.83
Microbe Life Plus-C, 2.5 gal (CA ONLY)
Plus-C 2.5 Gal CA ONLYEnhances plant functions at the foliar level and the root zone in both soil and soilless substrates. Enhances photosynthesis and biological function by allowing plants to capture and utilize radiant energy more efficiently. Speeds uptake and distribution of essential macro- and micronutrients required for all plant metabolic functions and growth. Promotes plant vigor and reduces input costs while increasing yields. Use in addition to ALL nutrient and fertilizer programs for maximum yields. Enhances plant functions at the foliar level and the root zone in both soil and soilless substrates Enhances photosynthesis and biological function Speeds uptake and distribution of essential macro- and micronutrients
$259.92$231.54
Milwaukee Valve 316SS FNPT Ball Valve
Milwaukee Valve 316SS FNPT Ball Valve (10SSOD-02-LL) This top of the line 316 Stainless Steel Milwaukee ball valve is a fire safe ball valve and is 1 piece ball valve construction. It also features a straight body style with Female NPT x Female NPT threaded connections with one side being pinned into place for zero movement during installation. The fire safe ball valve features a maximum pressure rating of 2000 PSI CWP and has a blowout proof stem made of 316SS and the temperature range of this ball valve is -20F° to 450F°. Milwaukee 10 Series Ball Valve Spec Sheet Valve Specifications Sizes Available: 1/4" FNPT 3/8" FNPT 1/2" FNPT Pressure Rating 2000 WOG Temperature Range -20°F to 450°F Valve Materials: Body A351-CF8M Ball Retainer A351-CF8M Ball 316 Stainless Steel Stem 316 Stainless Steel Seat 304 Stainless Steel Thrust Washer 316 Stainless Steel Seat RTFE Thrust Washer RTFE Stem Packing GRAPHOIL Gland 316 Stainless Steel Handle 304 Stainless Steel Handle Nut 304 Stainless Steel Handle Nut 304 Stainless Steel Belleville Washer 304 Stainless Steel PIN 304 Stainless Steel
$63.23 - $70.25
Mineral Oil 7 White NF (USP/NF)
BVV Mineral Oil 7 White NF (USP/NF) Food Grade White mineral oil can be used for many applications. Industrial, cosmetics, and food processing. Our Mineral Oil can be used in direct skin and food contact. Our oil is colorless, odorless and tasteless . This mineral oil can act as a non-conductive coolant, thermal fluid, lubricant, release agent, binder, defoamer, protective coating or float, sealing and polishing agent, dust control agent, and more. It has applications in three main areas: The industrial sector Cosmetics Food processing While those three sectors use this element most widely, it has a variety of other applications. White mineral oil is a standard household item, but has also found uses in some niche markets. The substance is versatile and has many properties making it useful in a range of applications. Food Grade Certified to FDA 21 CFR 172.878 BVV Mineral Oil 7 White NF - COA BVV Mineral Oil 7 White NF - Spec Sheet BVV Mineral Oil 7 White NF - SDS What is a food grade mineral oil? To use mineral oil in food preparation, it must be classified as a food-grade mineral oil. This is vital for health and safety as well as legal compliance. The Food and Drug Administration (FDA) has established standards any 'food-grade' substance must meet for both direct additions to foods and uses that may result in incidental contact with food. The requirements for purity, amount used, and processes vary based on how one uses mineral oil. The United States Pharmacopoeia (USP) and the National Formulary (NF) first created guidelines for the use of mineral oil in manufacturing. The FDA requires that food-grade mineral oil meet USP XX test requirements for readily carbonizable substances, which USP released in 1980, and USP XVII test requirements for sulfur compounds. It also needs to meet the specifications in Volume 45 of the Journal of the Association of Official Analytical Chemists. Mineral oil used as a lubricant for food-processing machinery must be registered with NSF International, an independent global food safety organization, as lubricants for incidental food contact to be used in food-processing plants under the jurisdiction of the U.S. Department of Agriculture (USDA). Other organizations oversee mineral oil use in other industries. For example, the Association of American Feed Control Officials (AAFCO) governs its use as a dust control agent for animal feeds. This classification is different, however, from food-grade mineral oil. Mineral oil used in the production of pharmaceuticals must be considered pharmaceutical-grade. The cosmetics and medical industry use highly refined mineral oil to avoid irritating the skin, eyes, and other body parts. Mineral oil chemical formula Mineral oils coming from crude petroleum oils vary in their make-up and contain complex structures. They include mixtures of straight and branched-chain paraffinic, naphthenic, and aromatic hydrocarbons. Alkanes, which are acyclic saturated hydrocarbons, are a significant component. They are made up of hydrogen and carbon atoms in a tree structure where all the carbon-to-carbon bonds are single. Mineral oil typically contains between 15 and 40 hydrocarbons. Mineral oil attributes Understanding the physical and chemical properties of mineral oil will help you to determine how best to use it in your industrial, food-processing, or other processes. These attributes may differ depending on the type of mineral used, how you use it, and whether any other substances get added to the oil. Mineral oil is a clear, colorless, and odorless liquid. This lack of strong physical qualities helps make it valuable in a variety of applications. Manufacturers can add it to products without changing their color, scent, flavor, or other crucial aspects. Mineral oil is also generally regarded as safe for human consumption, but in limited amounts. These features enable its use in the food processing and pharmaceutical sectors. Refined mineral oil does not clog pores, which allows for its use in cosmetics. Mineral oil has a density of 0.85 grams per milliliter (g/ml), and its specific gravity is 0.845 - 0.905. Its kinematic viscosity is greater than or equal to 38.1 millimeters squared per second (mm2/s). It is insoluble in water. The substance has an initial boiling point of 424.4 degrees Fahrenheit (°F) and a boiling range that extends up to 1189.4 °F. Its flash point is 275.00 °F closed cup and 380.00 °F open cup. It has an auto-ignition temperature of 500 °F, and its heat of combustion is 31.5 kilojoules per gram (kJ/g). As mentioned above, mineral oil has an NFPA flammability rating of one, a health rating of zero, and a reactivity rating of zero, meaning it is not a high fire risk. One of the most beneficial attributes of white mineral oil is its lubrication capabilities. This is the primary reason it has so many industrial, mechanical, food-processing, and medical applications. This property plays a crucial role in many manufacturing and food production processes. Its ability to transfer heat and its non-conductivity enable mineral oil's use as a coolant in a various electronic and mechanical equipment, as well as in industrial processes. Its resistance to water and other liquids, as well as insolubility in water, allow mineral oil to function as a sealant and binder in a variety of products. Safety Mineral oil is not regarded as an especially dangerous substance, but like all chemicals, users should handle it with appropriate care and precautions. A Material Safety Data Sheets (MSDS) for mineral oil may include the following information: Eyes: Mineral oil may cause eye irritation if it comes into contact with them. Flush eyes for several minutes and seek medical attention. Skin: It may cause skin irritation if prolonged contact with skin occurs. Remove contaminated clothing and wash affected areas or shower. Get medical attention if irritation persists. Inhalation: Inhaling mineral oil mist may irritate the respiratory tract and lungs. If this occurs, move to fresh air. Get medical attention if irritation persists. Ingestion: Ingestion can cause gastrointestinal irritation and result in nausea, vomiting, and diarrhea. If conscious, rinse mouth and drink water. Do not induce vomiting. If irritation persists, get medical attention. Mineral oil is combustible but has a low flammability rating. Having a National Fire Protection Association (NFPA) rating of one, means mineral oil must be preheated to ignite. Mineral oil has an instability rating of zero, which means it is stable even under fire conditions, and a health rating of zero, meaning it does not create any additional hazards beyond normal combustibility. You can extinguish a mineral oil fire using water fog, foam, dry chemical powder, or carbon dioxide (CO2) but should not use a water jet as this can spread the fire.If you encounter a spill of mineral oil, keep unnecessary personnel away, wear protective equipment, and absorb the spill with an absorbent material before cleaning the affected surface to remove any residue. Applications for mineral oil Mineral oil is inert, which makes it easy to use. Both consumers and businesses in a range of industries use mineral oil for a variety of applications. The three sectors named above primarily use mineral oil, but it appears across a wide range of industries and applications. Here are some of the most common uses in the industrial, personal care, and food production sectors. Use in cosmetics You can find mineral oil in many different cosmetics products including baby lotions, ointment, make-up remover, sunscreens, hair conditioner, and even tissues. Mineral oil is an ideal base material for many of these products because it is inert, colorless, and odorless. Mineral oils may appear in cosmetics as liquid oils or solid waxes. Some kinds of mineral oils are comedogenic, meaning they clog pores. Because of this, the mineral oil used in skincare and cosmetic products is noncomedogenic and does not clog pores. In fact, cosmetics companies often describe mineral oil as having moisturizing, protective, and cleansing properties for the skin. Additionally, these oils are used to give cosmetic products film-forming and water-repellent features as well as increased firmness. Use in food processing The food processing and preparation industries frequently use mineral oil. Sometimes, manufacturers add mineral oil directly to food. At other times, mineral oil assists in the production process but is not added to food directly. As mentioned earlier, all mineral oil that may come into contact with food must achieve classification as food-grade, and it must be used in accordance with all relevant laws and regulations. Food producers use mineral oil as a: Binder, release agent, or lubricant in bakery products, dehydrated foods, egg white solids, and in tablets or capsules for adding nutrients, flavoring, spices, or for use as a dietary supplement Release agent, sealing agent, and polishing agent in confectioners Protective coating on raw fruits and vegetables Defoamer in vinegar and beet sugar production Dough divider Dust control agent for grains. Binder, release agent, and lubricant in the manufacturing of yeast Mineral oil plays a role in some of the non-food products used to prepare, serve, and eat food. In these situations, the oil should also be food-grade. When applied to cookware, bakeware, and cooking utensils, mineral oil prevents food from sticking to them. People rub it onto the surface of wooden cutting boards, bowls, and utensils to prevent them from absorbing water, which can damage them. Mineral oil also prevents wood-based cooking tools from absorbing food liquids and odors, which makes cleaning easier. It acts as a lubricant for food processing equipment as well. Industrial, mechanical, and electrical uses Mineral oil serves to assist with various industrial, mechanical, and electrical purposes. It is an effective lubricant for industrial equipment and often functions as a processing aid. It is an element that helps make up various substances used in industrial processes, such as lubricants, greases, dyes, polymers, and surface treatment products. Mineral oil also acts as a thermal fluid or non-conductive coolant in various electric components. In refrigerators and oil-based electric heaters, mineral oil is used as a cooling liquid. In switchgear, it serves as an insulator and a coolant to diffuse switching arcs. In the production of plastics, mineral oil is used to control the melt flow rate of finished polymer and act as a release agent. Automotive equipment frequently uses mineral oil, primarily as a component in hydraulic liquids in automotive suspension, as well as in lubricants in brake fluids and motor oil.
$21.08 - $6,884.87
Mini Dry Ice Shaker
Miniature Dry Ice Shaker Miniature Dry Ice Shaker for creating a faster and cleaner extract. This is a fully sealed extraction system that only requires Dry Ice to Operate. It features a removable collection cap and interchangeable filter screens. This kit includes the following filter screens: 2x -- 100 Micron Screens 2x -- 120 Micron Screens 2x -- 160 Micron Screens 2x -- 190 Micron Screens
$54.80$42.15
Mini Stainless Steel Diamond Miners
Mini Stainless Steel Diamond Miners The Mini Diamond miner eliminates the need for glass jars and adds safety to your degassing procedure. It also gives you multiple viewing angles to see your diamond growth. A glycerin filled compound gauge gives you easy readout of pressure inside the vessel. Specifications: 304 grade stainless steel Stainless Steel Butterfly Ball Valve -40 to 230C In-Line Sight glass Compound Gauge High pressure clamps MAWP: 100 psi
$210.76 - $316.14
You have seen 1104 out of 1721 products