V4D 4CFM Two Stage Vacuum Pump

Description

BVV™ V4D 4CFM Two Stage Vacuum Pump

This is the BVV™ V4D 4CFM Two Stage Vacuum Pump used in botanical extraction.

Please refer to these charts for vacuum specifications at altitude and conversions:

Key Feature 

  • Internal Check Valve
  • Oil Mist Filter Cap
  • Larger Oil Reservoir for longer oil life
  • Lightweight
  • Rubber Feet for noise dampening
  • Reliable, economical, and efficient
Models BVV4D BVV7S BVV9D
Stage 2 1 2
Ultimate Vacuum (Microns) 15 75 15
Refrigerant Classes A1 Non-Toxic, Non Flammable
Dimensions (in) 12.4 x 4.8 x 10.16 12.4 x 4.8 x 10.16 15 x 6.3 x 11.22
Weight (lbs) 19.4 16.5 32
Free Air Displacement 4.3 CFM 6.4 CFM 8.5 CFM
Motor Size (HP) RPM 1 HP 3440 RPM
Oil Capacity 10oz / 300ml 14.5oz / 410ml 24oz / 680ml
Voltage 110V 60 Hz
Power Cord Hard Wired 3m / 9.8' Power Cord
Power Switch Standard On / Off
Operating Temperature Range 32F to 125 F (0C to 52C)
Gas Ballast Valve Yes No Yes
Intake Fittings Stainless Steel Inlet Fitting with 1/4" SAE & 3/8" JIC Male Ports

 

Pump Warranty Information

  • Customers using solvents such as stabilization resin, rotaries (MinWax™, Gator Venom™ etc.), alcohol and other polar solvents must use the vacuum pumps in conjunction with a cold trap for evacuations in excess of 5 minutes. (Excludes Cactus Juice™)

  • If the consumer is using the pump for prolonged periods of time exceeding 5 minutes we require that a cold trap is used or the pump warranty is void.

  • These stabilization resins have the ability to break down the internal components of the pump that are plastic resulting in a seized motor voiding all warranties.

  • When evacuation exceeds 5 minutes these solvents begin to vaporize and then re-condense in the vacuum pump reservoir. Once enough solvent re-condenses in the pump displacing the oil the plastic internal components may begin to warp, melt or seize. The use of a cold trap will condense the vapors prior to making their way to the vacuum pump preventing pump damage due to excessive use. Furthermore, Minwax Wood Hardener™ is not to be used with any vacuum pumps, EVER. (A seized motor will result within the first use.)

  • To prevent these issues from happening to your process, change the Oil after each vacuum pump use, Even if the use time is only 5min.

V4D 4CFM Two Stage Vacuum Pump

Product form

SKU: BVV4D

$497.04

    • Guaranteed secure & safe checkout.

      shop pay
    • Want it cheaper? Call us for a wholesale or processor discount. 331-281-0154
    Pay whenever you want

    Easily pay within 30 days after you have received your package.
    Read more

    Description

    BVV™ V4D 4CFM Two Stage Vacuum Pump

    This is the BVV™ V4D 4CFM Two Stage Vacuum Pump used in botanical extraction.

    Please refer to these charts for vacuum specifications at altitude and conversions:

    Key Feature 

    • Internal Check Valve
    • Oil Mist Filter Cap
    • Larger Oil Reservoir for longer oil life
    • Lightweight
    • Rubber Feet for noise dampening
    • Reliable, economical, and efficient
    Models BVV4D BVV7S BVV9D
    Stage 2 1 2
    Ultimate Vacuum (Microns) 15 75 15
    Refrigerant Classes A1 Non-Toxic, Non Flammable
    Dimensions (in) 12.4 x 4.8 x 10.16 12.4 x 4.8 x 10.16 15 x 6.3 x 11.22
    Weight (lbs) 19.4 16.5 32
    Free Air Displacement 4.3 CFM 6.4 CFM 8.5 CFM
    Motor Size (HP) RPM 1 HP 3440 RPM
    Oil Capacity 10oz / 300ml 14.5oz / 410ml 24oz / 680ml
    Voltage 110V 60 Hz
    Power Cord Hard Wired 3m / 9.8' Power Cord
    Power Switch Standard On / Off
    Operating Temperature Range 32F to 125 F (0C to 52C)
    Gas Ballast Valve Yes No Yes
    Intake Fittings Stainless Steel Inlet Fitting with 1/4" SAE & 3/8" JIC Male Ports

     

    Pump Warranty Information

    • Customers using solvents such as stabilization resin, rotaries (MinWax™, Gator Venom™ etc.), alcohol and other polar solvents must use the vacuum pumps in conjunction with a cold trap for evacuations in excess of 5 minutes. (Excludes Cactus Juice™)

    • If the consumer is using the pump for prolonged periods of time exceeding 5 minutes we require that a cold trap is used or the pump warranty is void.

    • These stabilization resins have the ability to break down the internal components of the pump that are plastic resulting in a seized motor voiding all warranties.

    • When evacuation exceeds 5 minutes these solvents begin to vaporize and then re-condense in the vacuum pump reservoir. Once enough solvent re-condenses in the pump displacing the oil the plastic internal components may begin to warp, melt or seize. The use of a cold trap will condense the vapors prior to making their way to the vacuum pump preventing pump damage due to excessive use. Furthermore, Minwax Wood Hardener™ is not to be used with any vacuum pumps, EVER. (A seized motor will result within the first use.)

    • To prevent these issues from happening to your process, change the Oil after each vacuum pump use, Even if the use time is only 5min.

    Returns & Delivery

    When will my order be delivered?

    We ship worldwide. Your order will be packaged really carefully and delivered wherever you want. Delivery takes between 2-4 business days. You will receive an e-mail after ordering with more information about the delivery.

    Can I return my product?

    Orders can be returned or exchanged within 30 days of receiving the parcel, providing they are in original resalable condition.

    What can I do if my item (or part of it) is damaged?

    We work hard to deliver your items without damage. Orders can be returned or exchanged within 30 days of receiving the parcel, providing they are in original resalable condition.

    Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?
      Create account