Low Temp Chillers

2 products


  • NEOCISION 20L Chiller (-40c) - ETL Rated Shop All Categories BVV

    Neocision 20L Chiller (-40c) - ETL Rated

    NEOCISION 20L Chiller (-40c) - ETL Rated     Product Name Circulating Chiller Model NEO20L-40 Reservoir volume L) 20L Refrigeration performance No-load minimum temperature (℃) A: ﹣ 20℃ ( Customizable: ﹣ 30℃ / C: ﹣ 40℃ Best operating temperature (℃) A: ﹣ 20℃ ~ 20℃B: ﹣ 30℃ ~ 20℃C: ﹣ 40℃ ~ 20℃ Best operating environment (℃) ≤30 Environmental relative humidity (%RH) ≤65 Cooling capacity at -40 ℃ kw 0.7 Refrigerant R404A Electrical performance Cooling unit power (W) 1500 Sensor pt100 Controller, monitor liquid crystal Computer interface R485 optional safety protection Compressor delay protection, machine leakage,over-current, over-voltage protection Power AC230V±10%/60HZ Pump Power (W) 15 Maximum flow (L/min) 10 Maximum lift (m) 2.5 Liquid inlet and outlet pipe diameter (mm) φ18 Whole machinefunction Total Weight (Kg) 105 Tank opening/depth ( mm) φ300mm*300mm Out size (mm) 420*580*790 Adaptation rotary evaporator (volume* number) 10L*2 Note The equipment can be customized to different supply voltage frequency; different flow head external circulation system and external magnetic stirring device.         TEMP: Displays the measured temperature value. To set the desired temperature, press the setting key until the TEMP SET value flashes. Press the setting key again to confirm the parameter. SET: Displays the desired temperature value set manually. RUN: Indicates that the chiller is operating. Cooling Indicator: Appears when the chiller is cooling. Circulation Indicator: Appears when the pump is operating. TIME: Displays the set running time; this value countdowns to zero and operation stops. To set a timer, press the setting key. When the TIME value flashes, enter the desired time using they arrow keys. Leave at zero if a timer is not needed. Silence Indicator: Appears when an alarm has been silenced. Alarm Indicator: It will appear when there is an alarm. Settings: Used for manually setting values and parameters. Left Arrow: Shifts to the numbers on the left to set desired value. Down Arrow: One push will decrease 1 digit; A long press will decrease digits faster. Up Arrow: One push will increase 1 digit; A long press will increase digits faster. Cooling Key: Press and hold key for more than 4 seconds to control start/stop the cooling function. Circulation Key: Press to start/stop the circulation function.   Note: After all parameters have been input, press the cooling key for four seconds to being operation. Instructions Before Use The unit should be used under the following conditions: Place on a stable, non-combustible flat surface Ambient temperature of 5 ~ 35 ℃ Relative humidity ≤ 85% Atmospheric pressure: (86 ~ 106) KPa Altitude not higher than 2000 meters Power: 5L AC 110V±10%/60HZ, 20L: AC230V±10%/60HZ Keep away from any heat, corrosive gasses, strong vibration and electromagnetic sources. Provide a minimum of 300mm of space for proper ventilation (front and rear) Do not spill liquid anywhere other than the bath. When setting temperatures pay attention to freezing points (ethanol/ethylene glycol). When operating for the first time after replacing the heat transfer fluid there may be air trapped in the circulating pump, follow these instructions to purge: a. Disconnect the outlet line from the application NOTE: Fluid may leak from application, be ready with a bucket or plug the port. Hold the Outlet hose above the top of the bath so fluid does not drain out. b. Place the outlet hose into a clean collection bucket. c. Hold the outlet hose firmly so it does not fall out of the collection bucket d. Wearing safety glasses to shield any splashes, turn on the circulating function. e. After the liquid flow significantly increases, turn off the circulator. f. Reconnect the hoses to your application’s ports.        

    $6,757.90

  • BVV -80C Chiller - 220v/60hz Shop All Categories BVV

    BVV -80C Chiller - 220v/60hz

    BVV -80C Chiller - 220v/60hz      This recirculating chiller is great for low temperature applications. With the a powerful pump it is able to circulate fluid while at -80°C. The chiller includes valves for the inlet and outlet port with 3/4" FNPT connections. The chiller also includes two barbs to adapt to 5/8" tubing, along with 2M of insulated silicone tubing.   Technical Data 3 Phase Single Phase Reservoir: 10L 10L Flow: 35L/min 35L/min Lift: 12m 12m Refrigerant: R404/R23 R404/R23 Low Temperature: -80℃ -80℃ Cooling capacity: 8048~1260W 7665~1200W @30°C 8048W 7665W @0°C 6021W 5735W @-40°C 4326W 4120W @-80°C 1260W 1200W Max. Input Current: 17 amps 24 amps Power supply: 220V/60Hz/3Φ 220V/60Hz/1Φ Circulator Low-temperature CoolantCirculation Pump Low-temperature CoolantCirculation Pump    

    $16,720.58

Login

Forgot your password?

Don't have an account yet?
Create account