Distillation
Julabo PRESTO A85
Julabo PRESTO A85 Reactor temperature control, tests for all kinds of substances or temperature simulation – Presto A30 are made for highly precise temperature control and rapid temperature changes, providing large heating and cooling capacities covering a working temperature range from -92 °C to +250 °C. Highly efficient components allow extremely fast compensation of exothermic and endothermic reactions. Lab users benefit from high flow rates, constant pressure and a controlled build-up of pump pressure. Changes in the temperature-control fluid viscosity are balanced dynamically. Permanent internal monitoring and self-lubricating pumps contribute to the new PRESTO’s long service life. A special feature of the PRESTO is the integrated 5.7’’ industrial color touch screen. Key Benefits: For highly precise, external temperature applications Rapid heating and cooling Fast compensation of exothermic reaction Wide working temperature ranges without changing fluids Highest performance with small footprint Space-saving design optimizes space utilization in your lab NEW 5,7 industrial color TFT touch screen well-organized view of important information with unmatched, intuitive user friendliness Up to 3 user level with password management NEW USB (Host und Device) NEW Ethernet NEW SD-Card slot RS232 / optional RS485 / optional Profibus DP Stand-by input Filling system accessible from the top Removable venting grid for simplified removal of dust Specs-At-A-Glance Temperature Stability (°C) ±0.05 … ±0.1 Cooling Capacity °C 200 20 0 -20 -40 -60 -80 kW 2.8 2.5 2.4 2.4 2.4 2.2 0.4 Heating Capacity (kW) 6 @ 400V, 6 @ 230V, 5.5 @ 208V Heating or Cooling Capability Both Working Temp Range (°C) -85 … +250 Pump Capacity Flow Rate (l/min) 35 … 76 Pump Capacity Flow Pressure (psi) 6.96 … 46.42 @ 400V, 6.96 … 46.42 @ 230V, 6.96 … 43.51 @ 208V Filling Volume Liters 9.5 (7 internal expansion) Digital Interface RS232, Optional Profibus, SD memory card, USB, Ethernet, Modbus, Optional RS485 Noise Level (dBA) 69 Power requirement V / Hz / A 3x 208/60/30 Cooling of Compressor 2-stage Air External Devices External Temp Probe, Remote Control Dimensions W x L x H (in) 24.1 x 42.6 x 49.3 Fluid Type Silicone, Fluorinert/Galden, Other Weight (lbs) 805 Product Data Sheet
$78,625.36 - $80,825.90
Julabo FL300
Julabo FL300 The FL series of chillers for routine cooling applications for the laboratory and industry. The PID control provides a temperature stability of ±0.5°C. All units can be cleaned easily and have a water-proof keypad with LED temperature indication. All instruments include an RS232 interface and alarm shutdown on the front of the units. The filling port is easily accessible from the top under a lift-up cover. Another hinged tray serves as a file for the operating manual or other documents concerning the installation. The removable venting grid allows for easy cleaning of the condenser with the drain tap accessible behind the grid. All models include a visible level indication. Air-cooled units have venting slots are on the front and rear enabling installation next to a wall or another apparatus (space saving). Specifications Order No. 9660003 Model Series FL Series Category Recirculating Coolers Working Temperature Range (°C) -20 ... +40 Temperature Stability (°C) ±0.05 Display Resolution 0.01 °C Temperature Display LED Cooling capacity (Medium Ethanol) °C 20 0 -10 -20kW 0.3 0.2 0.15 0.1 Pump capacity Flow Rate (l/min) 15 Pump Capacity Flow Pressure (psi) 5.08 Pump Connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling Volume Liters 3 ... 4.5 Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 133 Global Warming Potential for 1430 Carbon dioxide equivalent stage 1 (t) 0.19 Digital Interface RS232, Optional Profibus Ambient Temperature 5...40 °C Dimensions W x L x H (inch) 9.8 x 19.7 x 23.6 Weight (LBS) 86 Noise Level (dBA) 55 Description Suitable fluids: water, water-glycol mixture, JULABO Thermal bath fluids Included with 2 barbed fittings for tubing 3/4" inner dia. (pump connections G3/4" male) Cooling of Compressor Air Available Voltage Versions -115V/60HZ -230V/50HZ-230V/60HZ Product Data Sheet Manual
$6,604.44
Julabo FL7006
Julabo FL7006 The FL series of chillers for routine cooling applications for the laboratory and industry. The PID control provides a temperature stability of ±0.5°C. All units can be cleaned easily and have a water-proof keypad with LED temperature indication. All instruments include an RS232 interface and alarm shutdown on the front of the units. The filling port is easily accessible from the top under a lift-up cover. Another hinged tray serves as a file for the operating manual or other documents concerning the installation. The removable venting grid allows for easy cleaning of the condenser with the drain tap accessible behind the grid. All models include a visible level indication. Air-cooled units have venting slots are on the front and rear enabling installation next to a wall or another apparatus (space saving). Key Benefits: Ergonomic design and easy operation Splash-proof keypad Large, bright LED display Reliable Microprocessor PID temperature control Filling level indicator Powerful immersion pumps, suitable for continuous operation Permissible temperature in return line +80°C Easy filling from the top with hinged protective lid Low liquid level protection with optical and audible alarm signal Integrated stainless steel bath tanks Removable venting grid for cleaning of the condenser Front drain No side vents RS232 interface for PC-connection IP class according to IEC 60529: 21 Alarm output, potential-free change-over contact (max. 30 VA) Pressure Indicator By-pass valve to adjust pump pressure Specifications Order No. 9666070 Model Series FL Series Working Temperature Range (°C) -20° to +40° Temperature Stability (°C) ±0.05 Temperature Control PID temperature control Display Resolution 0.01 °C Temperature Display LED Cooling Capacity °C 20 0 -10 -20 kW 7 5.1 3 1.55 Pump capacity Flow Rate (l/min) 60 Pump Capacity Flow Pressure (psi) 7.25...87.0 Pump Connections G1 1/4-inch Filling Volume Liters 39...47 Barbed fittings diameter (inner dia. / mm) 1-inch Refrigerant R404A Digital Interface RS232, Optional Profibus Ambient Temperature 5…40 °C Noise Level (dBA) 74 Classification Classification III (FL)according to DIN 12876-1 Included with 2 barbed fittings for tubing 3/4" inner dia. (pump connections G1 1/4"male) Cooling of Compressor Air Power requirement V / Hz / A 3x 230/60/23 Cooling capacity °C 7kW (@ 20°C), 6.4kW (@ 10°C), 5.1kW (@ 0°C), 3kW (@ -10°C), 1.55kW (@ -20°C) Alarm Signal acoustically & optical Temperature Selection / Display °C Volumetric Capacity Liters 39...47 Outer dimensions W x L x H inch 30.7 x 33.5 x 58.3 Available Voltage Versions 230 V / 3 Ph. / 60 Hz, 400 V / 3Ph. / 50 Hz Other Characteristics Removable venting grid for convenient cleaning to maintain cooling performance. Internal pump by-pass valve to regulate pressure Characteristics / Display Easy to read: Large LED temperature display for actual value and setpoint(resolution 0.1 °C) Characteristics / Operation Simple and fast : Convenient 3-key setpoint adjustment (FLmodels) Characteristics / Temperature Control Precise: PID Temperature control with set control parameters, temperature stability ±0.02…±0.2 °C Characteristics / Refrigeration Technology Consistent cooling capacity: Easily removable venting gridfor quick and easy cleaning Characteristics / Technical Features Serial connection: RS232 interface for PC connection, e.g. data communication and recording of measured values
$24,502.04 - $27,384.08
Julabo FP51-SL
Julabo FP51-SL JULABO Ultra-Low Refrigerated Circulators for heating and cooling are suitable for external temperature tasks. Powerful circulating pump systems and high heating and cooling capacities guarantee short heat-up and cool-down times. ACC ‘Active Cooling Control‘ provides active cooling control across the whole temperature range. An energy saving feature with only minor loss of heat is provided by the proportional cooling capacity control in the ‘FP’ refrigeration units. The inevitable dust accumulation that occurs in refrigeration systems is solved by means of an easily removed venting grill, which allows for easy cleaning. The units are equipped with handles or castors for an easy transportation. All models have a drain tap on the front allowing the fluid to be drained easily. Additionally the instruments are equipped with an improved insulation to help avoid ice-formation, and have a visual liquid level display. Specifications Order No. 9352751 Model Series HighTech Working Temperature Range (°C) -51°... +200° Temperature Stability (°C) ±0.05 Temperature Control ICC intelligent cascade control, TCF temperature control features, Absolute temperature calibration 3-point Display Resolution 0.01 °C Integrated Programmer 6x60 steps Temperature Display VFD, LCD Heating Capacity (kW) 3 Cooling Capacity 0.26 kW @ -40 °C, 1 kW @ 20 °C,1.5 kW @ 0 °C, 2 kW @ 20 °C Pump capacity Flow Rate (l/min) 22-26 Pump Capacity Flow Pressure (psi) 5.8-10.2 Pump Capacity Flow Suction (psi) 2.9-5.8 Pump Connections M16x1 Filling Volume Liters 11 Bath opening / bath depth (W x L / D inch) 7.1 x 4.7 / 7.9 Barbed fittings diameter (inner dia. / mm) 8/12 Refrigerant R507 External Pt100 Intergrated Digital Interface RS232, RS485, Optional Profibus Ambient Temperature 5…40 °C Noise Level (dBA) 53 Classification Classification III (FL)according to DIN 12876-1 Included with 2 barbed fittings for tubing 8 and 12mm inner dia (pump connections M16x1) Analog Connection Input/Output Optional Cooling Coil optional Accessory (8970243) Cooling of Compressor Air Power requirement V / Hz / A 3x 230/60/14 Heaters 3kW Cooling capacity °C 2kW (@ 20°C), 1.5kW (@ 0°C), 1kW (@ -20°C), 260W (@ -40°C) Alarm Signal acoustically & optical Temperature Selection / Display °C / °F Volumetric Capacity Liters 11 Outer dimensions W x L x H inch 18.1 x 23.6 x 35.4 Available Voltage Versions 230V/3Ph/50Hz 400V/3Ph/50Hz 230V/3Ph/60Hz 230V/3Ph/60Hz (Canadian and US NRTL Certified) Other Characteristics Optional: Electronic module with analog connections for external programming, temperature recorder, standby, alarm (Order no. 8 900 100). Characteristics / Display Additional plain textinformation: LCD dialog display for interactive operation with plain textdisplay, Easy to read VFD Comfort display for simultaneous display of 3 values, warning functions, high temperature cut-off, pump stages (resolution 0.01 °C), Pump stage and liquid level: Backlit indicator for selected pump stages and filling volume Characteristics / Operation Comfortable and detailed: Comfortable keypad with additional menu functions for pump stages, calibration, control parameters, programmer, warnings, etc. Characteristics / Temperature Control For perfect results: Intelligent Cascade Control, automatic & self optimizing adjustment of PID control parameters, temperature stability ±0.005 °C internal, Characteristics / Refrigeration Technology 100 % Cooling capacity: Active Cooling Control for cooling available throughout the entire working temperature range, fast cool-down even at higher temperatures, Condensation and ice protection: A heated cover plate prevents condensation or ice build-up in the bath, Consistent cooling capacity: Easily removable venting grid for quick and easy cleaning, Energy saving cooling: Proportional cooling control for automatic adjustment of cooling power or temporary switch-off of compressor as needed to save up to 90 % energy in comparison to unregulated co. Characteristics / Technical Features Clever pump system: Reliable and consistent pump capacity, electronically adjustable pump stages, Control from the external application: External Pt100 sensor connection for precisemeasurement and control directly in the external application, Connection compliant to standard: RS232/RS485 dual-interface for serial data transmission according to EIA-485 industry standard (2-wire bus technology), upgradable with Profibus DP, Optimal program control: For the execution of time and temperature dependant profiles, 6 temperature profiles with 60 steps max., with real time clock, Automatic control of operating time: Electronic countdown-timer function for timer-programmed unit shut-down, standby mode after programmed time expires. Characteristics / Warning & Safety Functions Early warning system for high/low temperature limits: Maximum safety for applications, optical and audible alarm, convertible to automated cut-off function, Early warning system for low liquid level: Maximum safety for applications, optical and audible alarm, allows user to refill bath fluid before the unit shuts down, Enhanced protective functions : Maximum safety, adjustable high temperature cut-off or dry-running protection, additional display of setpoints permits easy and precise adjustments, For flammable bath fluids: Classification III (FL) according to DIN 12876-1
$18,754.88 - $20,027.64
Welch WOB-L Pump 2581
Welch-L Pump 2581 ***Note: This item has a possible 1-2 week lead time depending on stock availability.*** Product Details Economical Oil Free Adjustable Vacuum Reliable WOB-L Piston pump is perfect for many common laboratory vacuum applications. Features: Vacuum to 5 Torr (29.8"Hg). Includes Vacuum Regulator and Gauge - simple to adjust and monitor vacuum level. Inlet Water Trap - float ball rises to seal off pump from accidental ingestion of water. Muffler quiets pump and filters discharge air. For use with dry or aqueous vapor applications only. Specifications Model 2581 Free Air Displacement @ 60 Hz, cfm (L/min) 3.5 (100) Ultimate Pressure, torr 5 Motor Power, HP (kW) at 60 Hz 1/3 (0.25) Inlet (Exhaust) Connection Thread NPT 3/8 Tubing Needed, I.D. in. (mm) 1/4 (7) Weight, lbs (kg) 24.5 (11.1) Dimensions, LxWxH, in (mm) 17x7.5x12 (430x420x190) 115V Order Number 2581B-50 / 2581B-24
$2,279.00 - $2,612.00
Welch WOB-L System 2511
Welch WOB-L System 2511 ***Note: This item has a possible 1-2 week lead time depending on stock availability*** Product Details Use this easy system to collect waste into 1.2 Liter autoclaveable collection receiver. Includes vacuum measurement and regulation. Reservoirs are protected from overflow by float valve; inlet line hydrophobic filter further protects pump. Vacuum Pump is reliable WOB-L piston pump, perfect for aqueous vapors, buffer, and mild bleach solutions . Not for use with organic solvents / acids / bases. Model Number 2511 Applications Solution aspiration / collection; vacuum filtra Type Laboratory Vacuum Pump Free Air Displacement cfm (l/min.) @60Hz 0.39(11) Free Air Displacement m3/hr (l/min.) @50Hz 0.55(9.2) Ultimate Pressure 219(292) Maximum Vacuum 21.3 Max Pressure PSIG (pascal) 33(3.3 x 105) Motor Horsepower (watts) 1/30(25) Tubing Needed 3/16(5) Intake Thread NPT 3/16 in. Hose Overall Dimensions LxWxH in. (cm) 7.6x4.5x7.5 (19.4x11.4x19.1) Ship Weight 11.0(5) Shipping Dimensions LxWxH in. (cm) 11" x 7" x 7" (39x31x32)
$941.00
Welch DryFast Collegiate Diaphragm Pump 2014
DryFast Collegiate Diaphragm Pump 2014 ***Note: This item has a possible 1-2 week lead time depending on stock availability*** Product Details Chemical Resistant Oil-Free Tuneable Vacuum Welch DryFastTM PTFE Diaphragm Vacuum Pumps enable precise vacuum control for organic evaporations with exclusive Advanced Vapor Management (AVM). Oil-Free, portable, chemical resistant, 1 head diaphragm design simplifies maintenance. Choose from seven dry PTFE vacuum pump models with flows up to 70 L / min and adjustable vacuum down to 2 Torr. Economical DryFastTM vacuum pumps are perfect for tough lab applications. Model Number 2014 Applications Vacuum Filtration, SPE, Rotary Evaporations (volatile solvents <80oC B.P., volume <2 liters), pumping harsh vapors & gases, general laboratory vacuum Type Laboratory Vacuum Pump Free Air Displacement cfm (l/min.) @60Hz 1.2(35) Free Air Displacement m3/hr (l/min.) @50Hz 1.75(29) Ultimate Pressure 40(53) Maximum Vacuum 28.3 Motor Horsepower (watts) 1/5(150) Adjustable Vac. / Gas Ballast Yes Tubing Needed 1/4(7) Intake Thread NPT M14(1/8) Overall Dimensions LxWxH in. (cm) 12x7.0x8.3 (30.5x 17.8x21.1) Ship Weight 19(8.6) Shipping Carton Dimensions LxWxH in. (cm) 21x14x15 (52x35x37) Adjustable Vacuum Knob
$1,602.00
WELCH Self-Cleaning Vacuum System 2025
WELCH Self-Cleaning Vacuum System 2025 Product Details Automatic Self-cleaning purge maintains efficiency, extends diaphragm life Free air displacement: 35 L/min (1.2 CFM) Incremental ballast switch enables fast response to bumping / foaming Complete oil-free dry vacuum systems for rotary evaporators and concentrators. Corrosion-resistant PTFE diaphragm vacuum pump systems enable superior control and efficiency for each evaporation. Provides controlled solvent stripping in flasks up to 5 L. Use 9 torr Model 2025 for solvents with atmospheric B.P. <120o C. Includes analog gauge and vacuum regulation. Inlet and exhaust separators protect pump and lab atmosphere. Specification Model Number 2025 Applications Controlled vacuum for Rotary evaporators, Centrifugal concentrators, and other evaporative processes. Type Laboratory Vacuum Pump Free Air Displacement m3/hr (l/min.) @50Hz 1.2(34) Ultimate Pressure 1.7(28) Max Pressure PSIG (pascal) 29.5 Adjustable Vac. / Gas Ballast 1/5 Tubing Needed Yes Intake Thread NPT 1/4 Overall Dimensions LxWxH in. (cm) 13.6x12x11.3 (34.5x30.5x28.7) Ship Weight 36(16.3) Intake Catch Jar Yes Exhaust Catch Jar Yes
$3,725.00 - $3,742.00
Polyscience 1.5 HP Chiller, Positive Displacement Pump; Air-Cooled
Polyscience 1.5 HP Chiller, Positive Displacement Pump; Air-Cooled Description: 1.5 HP Chiller, Positive Displacement Pump; Air-Cooled Display: LED Connectivity: Optional: RS232, RS485 Working Temperature Range °C: 5° to 35° Temperature Stability °C: ±0.5° Temperature Calibration Capability: 1-point Pump Type: Positive Displacement Key Features High capacity cooling for lasers, electron microscopes, and other laboratory applications Small footprint conserves floor space Displays temperature and pressure or flow rate simultaneously User-adjustable temperature, pressure, and flow rate alarms Simple operation and maintenance Air- or water-cooled Positive displacement (PD) or turbine (T) pump; other pump options also available Common Specifications Working Temperature Range °F 41° to 95° Working Temperature Range °C 5° to 35° Reservoir Capacity (gallons) 3.5 Reservoir Capacity (liters) 13.25 Reservoir/Tank Material Polyethylene Reservoir Cover Screw-on Cap Cleanable Air Filter Yes Cleanable Fluid Filter Yes Temperature Stability °F ±0.9° Temperature Stability °C ±0.5° Display LED Display Resolution (Read) 0.1 Pump Type Positive Displacement Process Connections 1/2" (F) NPT Over-Temperature Protection / Failsafe Heater Control Yes Reservoir Liquid Level Indicator Yes Reservoir Drain Yes Maximum Ambient Temperature °F 95° Maximum Ambient Temperature °C 35° Overall Dimensions (L x W x H) (inches) 30.5 x 19 x 26 in Overall Dimensions (L x W x H) (cm) 78 x 48 x 66 cm Compressor Size (HP) 1.5 Refrigerant R134a Shipping Weight (pounds) 340.0 Shipping Weight (kilograms) 154.0 Catalog Page Number 104 Hz (Hertz) 60 Hz Only 50 Hz Only Part Number 6860P46A270D 6850P46A270E Maximum Pressure (psi) 100.0 83.0 Maximum Pressure (bar) 6.90 5.72 Maximum Pressure Flow Rate (gpm) 3.50 2.90 Maximum Pressure Flow Rate (l/min) 13.2 11.0 Cooling Capacity @ +10°C (W) 4420 3715 Cooling Capacity @ +20°C (W) 5200 4371 Cooling Capacity @ +30°C (W) 5980 5027 Heater Wattage 1000 1000 Electrical Requirements (VAC/Hz/Ph/A) 230/60/1/21.1 240/50/1/20.8 Regulatory Approvals TUV CSA, CUL, CE
$10,243.00
Huber Unichill 300T
Huber Unichiller 300T (Please Note: There is a 2 -3 weeks lead time) Description: Huber Unichillers offer better efficiency, stable pressure and delivery performance with a constant cooling water temperature compared to traditional tap water cooling. Chillers also reduce water consumption and help conserve the environment whilst lowering operating costs. Unichillers are suitable for the removal of heat from chemical processes, cooling technical plants or as a central cooling water supply for laboratories. All Unichillers are designed for continual operation at ambient temperatures up to +40°C. Installation in an outside areas is possible with optional weather protection and winter operation packages. Pumps are available with an extended pressure and flow rate for applications with a high pressure drops. The new multi-touch controller Pilot ONE offers a brilliant 5.7" touchscreen with graphic functions and a comfortable navigation menu. All important operating parameters and temperature values are neatly displayed on the touchscreen. Thanks to the new favorites menu, the one-click operation and the integrated technical glossary the operation is very easy, just like on a smartphone. Integrated USB and Ethernet ports allows connection to a PC or network, e.g. for remote control or data transmission. Environmentally-friendly, economic cooling solution High efficiency Precise temperature control Powerful circulation pump Intelligent energy management Reliable continuously operation with warning functions Pilot ONE controller with 5.7" touchscreen Digital filling level indicator 2 x USB (Host and Device), Ethernet and RS232 interfaces Heater options available Download Data Sheet Click Here 3 Year Warranty Register Please observe the notes on installation and/or the space requirements of our products. General information & temperature controller Temperature range -20...40 °C Temperature stability ±0.5 °C Controller Pilot ONE (E-grade "Basic") Safety class I / NFL Protection class IP20 Dimensions (W x D x H) 905 x 2172 x 1900 mm | 35.63 x 85.51 x 74.8 inches Weight -- kg | pounds Heating / cooling capacity Cooling capacity 15 0 -10 -20 °C ____________ 30 18 11 6 kW Cooling machine air-cooled Refrigerant (ASHRAE, GHS) R449A (A1, H280) Circulation pump Pressure pump max. 210 lpm ; 4.7 bar | 55.48 gpm ; 68.15 psi Pump connection G1 1/4 AG male Connections Pt100 connection Pt100 Digital interface RS232, Ethernet, USB Device, USB Host Operating data Old Sku 3020.0027.01 Permissible ambient temp. 5...40 °C Filling volume min. 14 Liters | 3.7 gal Volume of expansion 39 Liters | 10.3 gal Power supply 460V 3~ 60Hz
$128,600.00 - $129,100.00
Huber Unichiller 500Tw
Huber Unichiller 500Tw (Please Note: There is a 2 -3 weeks lead time) Description: Huber Unichillers offer better efficiency, stable pressure and delivery performance with a constant cooling water temperature compared to traditional tap water cooling. Chillers also reduce water consumption and help conserve the environment whilst lowering operating costs. Unichillers are suitable for the removal of heat from chemical processes, cooling technical plants or as a central cooling water supply for laboratories. All Unichillers are designed for continual operation at ambient temperatures up to +40°C. Installation in an outside areas is possible with optional weather protection and winter operation packages. Pumps are available with an extended pressure and flow rate for applications with a high pressure drops. The new multi-touch controller Pilot ONE offers a brilliant 5.7" touchscreen with graphic functions and a comfortable navigation menu. All important operating parameters and temperature values are neatly displayed on the touchscreen. Thanks to the new favorites menu, the one-click operation and the integrated technical glossary the operation is very easy, just like on a smartphone. Integrated USB and Ethernet ports allows connection to a PC or network, e.g. for remote control or data transmission. Environmentally-friendly, economic cooling solution High efficiency Precise temperature control Powerful circulation pump Intelligent energy management Reliable continuously operation with warning functions Pilot ONE controller with 5.7" touchscreen Digital filling level indicator 2 x USB (Host and Device), Ethernet and RS232 interfaces Heater options available Download Data Sheet Click Here 3 Year Warranty Register Please observe the notes on installation and/or the space requirements of our products General information & temperature controller Temperature range -20...40 °C Temperature stability ±0.5 °C Controller Pilot ONE (E-grade "Basic") Safety class I / NFL Protection class IP20 Dimensions (W x D x H) 1000 x 1100 x 1635 mm | 39.37 x 43.31 x 64.37 inches Weight -- kg | pounds Heating / cooling capacity Cooling capacity 15 0 -10 -20 °C_______________ 50 30 24 14 kW Cooling machine water-cooled Refrigerant (ASHRAE, GHS) R449A (A1, H280) Circulation pump Pressure pump max. 234 lpm ; 4.9 bar | 61.82 gpm ; 71.05 psi Pump connection G1 1/4 AG male Connections Pt100 connection Pt100 Digital interface RS232, Ethernet, USB Device, USB Host Operating data Old Sku 3030.0003.01 Permissible ambient temp. 5...40 °C Filling volume min. 12.7 Liters | 3.36 gal Volume of expansion 7 Liters | 1.85 gal Cooling water connection G1 1/4 AG Cooling water differential pressure min. 1,5 bar | 217.5 psi Cooling water pressure max. 6 bar | 87 psi Power supply 460V 3~ 60Hz
$149,200.00 - $149,700.00
Huber Minichiller 600 OLÉ
Huber Minichiller 600 OLÉ (Please Note: There is a 2 -3 weeks lead time) Description: The compact Minichillers are an economic and environmentally friendly cooling solution for many laboratory applications. A calculation of water and waste water costs shows that a Minichiller can save up to 48,000 litres of water in a working week and due to its low procurement price, return on investment is achieved within a very short time. The units have small footprints, only requiring 225 x 360 mm on the laboratory bench and are therefore suitable for cooling reactor blocks, vacuum pumps, rotary evaporators or heat exchangers. Minichillers allow stable application conditions due to constant values for temperature, pressure and throughflow quantities. They are also perfect for continuous operation at ambient temperatures up to 40°C. Despite the economic purchase price the coolers are well equipped and have a large temperature indicator, fill level indicator, as well as status LEDs for the pump, cooling and heating. A 1 kW heater is optionally available with which the temperature range can be extended to +100°C. Minichillers are available as both air and water cooled models and use natural refrigerants. The new OLÉ controller combines state-of-the-art technology with simple operation. OLÉ models are suitable for routine tasks in research and industry and are convincing as practice oriented basic equipment. Option: Pt100 sensor connection #10519 to display (not control) e.g. of the process temperature (only available factory fitted, additional charge) Environmentally-friendly, economic cooling solution High efficiency Precise temperature control Simple operation with menu navigation Robust stainless construction Reliable continuously operation with warning functions Easy to fill and empty Illuminated filling level indicator Bright, large OLED display USB and RS232 interfaces Download Data Sheet Click Here 3 Year Warranty Register Please observe the notes on installation and/or the space requirements of our products. General Information & Temperature Controller Temperature range -20...40 °C Temperature stability ±0.5 °C Temperature Display OLED Display Display resolution 0.1 °C Alarm message optical, acoustical Controller OLÉ Safety class I / NFL Protection class IP20 Dimensions (W x D x H) 280 x 490 x 424 mm | 11.02 x 19.29 x 16.69 inches Weight 36 kg | 79.38 pounds Heating / Cooling Capacity Cooling capacity 15 0 -10 -20 ° C0,6 0,5 0,35 15 kW Cooling machine air-cooled Refrigerant R290 (A3, H220) (0,085 kg) Circulation Pump Pressure pump max. 24 lpm ; 0.7 bar | 6.34 gpm ; 10.15 psi Suction pump max. 18 lpm ; 0.4 bar | 4.76 gpm ; 5.8 psi Pump connection M16x1 AG male Connections Digital interface USB, RS232 Operating Data Old sku 3006.0097.98 Noise Level 56 dB(A) Filling Volume min 2.8 Liters | 0.74 gal Volume of expansion 2.2 Liters | 0.58 gal Power supply 110-120V 1~ 60Hz Current max. 8,5 A
$6,990.00 - $7,490.00
Huber Ministat with Pilot ONE
Huber Ministat with Pilot ONE (Please Note: There is a 2 week lead time) Huber Ministats are the smallest cooling circulator in the world. Their small dimensions allow Ministats to be placed in the smallest of spaces, for example in a laboratory fume cupboard or inside technical plant. Despite their minimal size the systems are extensively fitted out and offer sufficient performance for temperature control of photometers, refractometers, viscometers, distillation apparatus, reaction vessels and mini-plants. The main applications are using external applications however the bath opening allows objects to be thermoregulated directly in a thermostat bath. A powerful pressure/suction pump with an infinitely controlled rotational speed ensures optimal circulation. The maximum pressure can also be regulated by an optional pressure sensor, meaning that sensitive glass reactors and apparatus can reliably be protected from breakage. Pilot ONE controller with Plug & Play technology Precise temperature control 5.7“ touchscreen and comfortable menu navigation Overtemperature and low level protection Safety class III/FL (DIN 12876) Powerful pressure/suction pump Programmer with calendar and clock functions 2-point calibration Download Ministat 125 Data Sheet Download Ministat 125w Data Sheet Download Ministat 230 Data Sheet Download Ministat 230w Data Sheet Download Ministat 240 Data Sheet Download Ministat 240w Data Sheet Click Here 3 Year Warranty Register Please observe the notes on installation and/or the space requirements of our products. General Information & Temperature Controller Huber Ministat 125 Huber Ministat 125w Huber Ministat 230 Huber Ministat 230w Huber Ministat 240 Huber Ministat 240w Temperature range -25...150 °C -25...150 °C -40...200 °C -40...200 °C -45...200 °C -45...200 °C Temperature stability ±0.02 °C ±0.02 °C ±0.05 °C ±0.02 °C ±0.02 °C ±0.02 °C Temperature Control TAC, self-optimizing (True Adaptive Control) TAC, self-optimizing (True Adaptive Control) TAC, self-optimizing (True Adaptive Control) TAC, self-optimizing (True Adaptive Control) TAC, self-optimizing (True Adaptive Control) TAC, self-optimizing (True Adaptive Control) Controller Pilot ONE(E-grade "Basic") Pilot ONE(E-grade "Basic") Pilot ONE(E-grade "Basic") Pilot ONE(E-grade "Basic") Pilot ONE(E-grade "Basic") Pilot ONE(E-grade "Basic") Safety class III / FL III / FL III / FL III / FL III / FL III / FL Protection class IP20 IP20 IP20 IP20 IP20 IP20 Dimensions (W x D x H) 8.86 x 14.57 x 16.89 in 8.86 x 14.57 x 16.89 in 10.04 x 17.72 x 18.74 in 10.04 x 17.72 x 18.74 in 11.81 x 18.31 x 20.31 inches 11.81 x 18.31 x 20.31 inches Weight 55.12 pounds 55.12 pounds 81.59 pounds 86 pounds 97.02 pounds 97.02 pounds Heating / Cooling Capacity Heating capacity 1 kW 1 kW 1,6 - 2,1 kW 1,5 kW 1,6 kW 1,6 kW Cooling capacity 100 20 0 -10 -20 °C0,3 0,3 0,21 0,15 0,05 kW 100 20 0 -10 -20 °C0.3 0,3 0,2 0,15 0,1 kW 100 20 0 -10 -20 -40 °C0,42 0,42 0,38 0,33 0,25 0,05 kW 100 20 0 -10 -20 -40 °C0,42 0,42 0,38 0,33 0,25 0,05 kW 100 20 0 -10 -20 -40 °C0,6 0,6 0,55 0,42 0,35 0,05 kW 100 20 0 -10 -20 -40 °C0,6 0,6 0,55 0,42 0,35 0,05 kW Cooling machine air-cooled water-cooled air-cooled water-cooled air-cooled water-cooled Refrigerant R290 (A3, H220) (0,066 kg) R290 (A3, H220) (0,06 kg) R290 (A3, H220) (0,099 kg) R290 (A3, H220) (0,06 kg) R290 (A3, H220) (0,099 kg) R290 (0,06 kg) Circulation Pump Pressure pump max. 22 lpm ; 0.7 bar 5.81 gpm ; 101.5 psi 22 lpm ; 0.7 bar5.81 gpm ; 101.5 psi 22 lpm ; 0.7 bar | 5.81 gpm ; 10.15 psi 22 lpm ; 0.7 bar | 5.81 gpm ; 10.15 psi 22 lpm ; 0.7 bar | 5.81 gpm ; 10.15 psi 22 lpm ; 0.7 bar5.81 gpm ; 101.5 psi Suction pump max. 16 lpm ; 0.4 bar4.23 gpm ; 58 psi 16 lpm ; 0.4 bar4.23 gpm ; 58 psi 16 lpm ; 0.4 bar4.23 gpm ; 58 psi 16 lpm ; 0.4 bar | 4.23 gpm ; 5.8 psi 16 lpm ; 0.4 bar | 4.23 gpm ; 5.8 psi 16 lpm ; 0.4 bar4.23 gpm ; 58 psi Pump connection M16x1 AG male M16x1 AG male M16x1 AG male M16x1 AG male M16x1 AG male M16x1 AG male Permissible viscosity 50 mm²/s 50 mm²/s 50 mm²/s 50 mm²/s 50 mm²/s 50 mm²/s Connections Digital interface Pt100 Pt100 Pt100 Pt100 Pt100 Pt100 Digital interface RS232, Ethernet, USB Device, USB Host RS232, Ethernet, USB Device, USB Host RS232, Ethernet, USB Device, USB Host RS232, Ethernet, USB Device, USB Host RS232, Ethernet, USB Device, USB Host RS232, Ethernet, USB Device, USB Host Operating Data Permissible ambient temp. 5...35 °C 5...40 °C 5 to 40 °C 5 to 40 °C 5 to 40 °C 5 to 40 °C Noise level - - 59 dB(A) - - Bath opening W x D / BD 178 x 80 / 120 mm | 7.01 x 3.15 / 4.72 inches 178 x 80 / 120 mm | 7.01 x 3.15 / 4.72 inches 170 x 85 / 135 mm | 6.69 x 3.35 / 5.31 inches 170 x 85 / 135 mm | 6.69 x 3.35 / 5.31 inches 205 x 85 / 157 mm | 8.07 x 3.35 / 6.18 inches 205 x 85 / 157 mm | 8.07 x 3.35 / 6.18 inches Bath volume 2.75 Liters | 0.73 gal 2.75 Liters | 0.73 gal 3.2 Liters | 0.85 gal 3.2 Liters | 0.85 gal 4.9 Liters | 1.29 gal 4.9 Liters | 1.29 gal Filling volume min 2 Liters | 0.53 gal 2 Liters | 0.53 gal 2.8 Liters | 0.74 gal 2.8 Liters | 0.74 gal 4.5 Liters | 1.19 gal 4.5 Liters | 1.19 gal Cooling water connection - G1/2 AG - G1/2 AG - G1/2 AG Cooling water differential pressure min. - 2 bar | 29 psi - 2 bar | 29 psi - 2 bar | 29 psi Cooling water pressure max. - 6 bar | 87 psi - 6 bar | 87 psi - 6 bar | 87 psi Power supply 110-120V 1~ 60Hz 110-120V 1~ 60Hz 208-240V 1~/2~ 50/60Hz 110-120V 1~ 60Hz 208V 2~ 60Hz 208V 2~ 60Hz Current max. 11,5 A 11,5 A 14 A 14 A 10,5 A - Fusing 16 A 16 A 16 A 16 A 2x16 A -
$10,400.00 - $13,850.00
Huber Minichiller 600w OLÉ
Huber Minichiller 600w OLÉ Description: The compact Minichillers are an economic and environmentally friendly cooling solution for many laboratory applications. A calculation of water and waste water costs shows that a Minichiller can save up to 48,000 litres of water in a working week and due to its low procurement price, return on investment is achieved within a very short time. The units have small footprints, only requiring 225 x 360 mm on the laboratory bench and are therefore suitable for cooling reactor blocks, vacuum pumps, rotary evaporators or heat exchangers. Minichillers allow stable application conditions due to constant values for temperature, pressure and throughflow quantities. They are also perfect for continuous operation at ambient temperatures up to 40°C. Despite the economic purchase price the coolers are well equipped and have a large temperature indicator, fill level indicator, as well as status LEDs for the pump, cooling and heating. A 1 kW heater is optionally available with which the temperature range can be extended to +100°C. Minichillers are available as both air and water cooled models and use natural refrigerants. The new OLÉ controller combines state-of-the-art technology with simple operation. OLÉ models are suitable for routine tasks in research and industry and are convincing as practice oriented basic equipment. Option: Pt100 sensor connection #10519 to display (not control) e.g. of the process temperature (only available factory fitted, additional charge). Environmentally-friendly, economic cooling solution High efficiency Precise temperature control Simple operation with menu navigation Robust stainless construction Reliable continuously operation with warning functions Easy to fill and empty Illuminated filling level indicator Bright, large OLED display USB and RS232 interfaces Natural refrigerant General Information & Temperature Controller Temperature range -20...40 °C Temperature stability ±0.5 °C Temperature Display OLED Display Display resolution 0.1 °C Alarm message optical, acoustical Controller OLÉ Safety class I / NFL Protection class IP20 Dimensions (W x D x H) 280 x 490 x 424 mm | 11.02 x 19.29 x 16.69 inches Weight 36 kg | 79.38 pounds Heating / Cooling Capacity Cooling capacity 15 0 -10 -20 ° C0,6 0,5 0,35 0,15 kW Cooling machine water-cooled Refrigerant R290 (A3, H220) (0,085 kg) Circulation Pump Pressure pump max. 24 lpm ; 0.7 bar | 6.34 gpm ; 10.15 psi Suction pump max. 18 lpm ; 0.4 bar | 4.76 gpm ; 5.8 psi Pump connection M16x1 AG male Connections Digital interface USB, RS232 Operating Data Old sku 3006.0127.98 Filling Volume min 2.8 Liters | 0.74 gal Volume of expansion 2.2 Liters | 0.58 gal Cooling water connection G1/2 AG Cooling water consumption 24 l/h Cooling water differential pressure min. 3 bar | 43.5 psi Cooling water pressure max. 6 bar | 87 psi Power supply 110-120V 1~ 60Hz Please take further technical information as well as information about the scope of delivery, accessories and peripheral devices from the PDF data sheet. In cases of doubt the details given in there apply. If nothing to the contrary is quoted then the performance data referred is at an ambient temperature of 20°C. Please observe the notes on installation and/or the space requirements of our products. The following voltage and frequency tolerances apply based on EN60034-1:Voltage +/- 5% for a frequency tolerance at the same time of +/- 2% Examples to illustrate this: Not permissible, for example. is -5% on the voltage and +2% on the frequency. Permissible, on the other hand, are tolerances of -5% on the voltage and -2% on the frequency. This equipment is compliant to US-SNAP and all applicable EU laws. The US-SNAP end-use for this equipment is the industrial process refrigeration. Certification by a Notified Body upon request. We reserve the right to make technical changes and correct errors. Illustrations can deviate from the original.
$7,490.00 - $7,990.00
Chemglass Caps With Aperture GL Threads High Temperatures
Chemglass Caps With Aperture GL Threads High Temperatures Open top cap for use with GL screw threads. Cap is made from PPS (polyphenylsiloxan) and will withstand temperatures up to 250°C.
$6.50
Flat Bottom Flask
Flat Bottom Flask Flat Bottom Flasks are used to capture and store material when used with a glass funnel. These flasks are flat bottomed and come with a non-jointed opening. Sizes Available: 500ml 1000ml *Notice to customers: All units are inspected for broken glassware or parts before leaving BVV™. If the unit arrives damaged (this does not include minor imperfections or scuffs in glassware), the customer MUST contact BVV™ within 72 hours from carrier delivery to file a claim. If the customer DOES NOT contact BVV™ within 72 hours from carrier delivery, then BVV™ cannot issue any replacement(s) or compensation for the item; a new purchase will need to be made for a replacement. **Glassware Safety Disclaimer: BVV™ is not responsible for failure of glassware which must be inspected before and after every use because it may eventually develop imperfections or damage through normal usage, mishandling, and stress caused by temperature variations. If an imperfection or damage is noted while inspecting the glassware DO NOT use the glassware because it can fail causing bodily harm or damage to the surrounding area.**
$15.00 - $17.00
BVV™ Dewar Glass Cold Trap
BVV™ Dewar Glass Cold Trap This dewar style glass is designed for maximum vapor condensation and it also has a 24/40 bottom joint and (2) GL-14 8mm Hose Barbs *Notice to customers: All units are inspected for broken glassware or parts before leaving BVV™. If the unit arrives damaged (this does not include minor imperfections or scuffs in glassware), the customer MUST contact BVV™ within 72 hours from carrier delivery to file a claim. If the customer DOES NOT contact BVV™ within 72 hours from carrier delivery, then BVV™ cannot issue any replacement(s) or compensation for the item; a new purchase will need to be made for a replacement.
$250.00
Chromatography Column Kit
Chromatography Column Kit Chromatography Column Kit This 3”x24” chromatography column features an internal volume of 2.7L. It’s commonly used for removing pesticides, separating components, and cleaning different chemical compounds. Additional consumables or accessories will be needed depending on application. Capacity can be increased with an additional reservoir adapted to the top 45/50 Rodaviss joint. Rodaviss joints are great for disconnecting any stubborn joints. Light grease is still recommended when assembling joints. This kit features: Casted base with 36” rod stand Support ring Chain clamp Needle control valve 3”x24” column with 2.7L capacity 45/50 Rodaviss joint Sintered disk Stop cock For additional information or questions regarding this kit, accessories, and consumables contact our customer support line. *Notice to customers: All units are inspected for broken glassware or parts before leaving BVV™. If the unit arrives damaged (this does not include minor imperfections or scuffs in glassware), the customer MUST contact BVV™ within 72 hours from carrier delivery to file a claim. If the customer DOES NOT contact BVV™ within 72 hours from carrier delivery, then BVV™ cannot issue any replacement(s) or compensation for the item; a new purchase will need to be made for a replacement. **Glassware Safety Disclaimer: BVV™ is not responsible for failure of glassware which must be inspected before and after every use because it may eventually develop imperfections or damage through normal usage, mishandling, and stress caused by temperature variations. If an imperfection or damage is noted while inspecting the glassware DO NOT use the glassware because it can fail causing bodily harm or damage to the surrounding area.**
$485.00
Baffled Tri-Clamp Condenser
Baffled Tri-Clamp Condenser This 304 Stainless Steel Tri-Clamp condenser allows the user to condense hot vapors and solvent while running an extraction system or use it as a heat exchanger if needed. It features internal baffles in the system allowing for better overall heat exchange, Tri-Clamp connections on each end and (2) 1/2" FNPT Ports on the side to allow various connections the user may need. The inside diameter of the tubing measures 7.5mm. BVV™ Baffled Tri-Clamp - Data Sheet
$270.00 - $3,750.00
Julabo SL-12 Heating Circulator
Julabo SL-12 Heating Circulator JULABO constant temperature circulators with a stainless steel bath tank for internal and external temperature control tasks. They are designed primarily for external temperature control. They have elevated performance for controlling the temperature of large or open systems. Smaller objects may be inserted directly into the circulator's bath at the same time. Models of the TopTech and HighTech series are available with a variety of bath sizes and functional characteristics. Bath covers and a variety of bath inserts for laboratory glassware are available as accessories Specifications Order No. 9352512 Model series HighTech Category Heating Circulators Working temperature range (°C) +20 ... +300 Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 6x60 steps Temperature Display VFD , LCD Heating capacity (kW) 3 Pump capacity flow rate (l/min) 22-26 Pump capacity flow pressure (psi) 5.8-10.2 Pump capacity flow suction (psi) 2.9-5.8 Bath opening / bath depth (W x L / D inch) 8.7 x 5.9 x 7.9 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 12 External Pt100 sensor connection integrated Digital interfaces RS232RS485Optional Profibus Ambient temperature 5...40 °C Dimensions W x L x H (inch) 11.8 x 16.9 x 18.5 Weight (LBS) 30.8 Classification according to DIN12876-1 Classification III (FL) Description Built-in cooling coil for tap water connection for temperature applications below or near ambient temperatures are integrated. Included with each unit 2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 male). Cooling coil integrated Bath tank Stainless steel Power requirement V / Hz / A 230/50-60/13 Additional voltage versions available
$4,688.00 - $9,149.00
BVV™ Terpenes Granddaddy Purple
BVV™ Terpenes Granddaddy Purple All sales are final. Orders can be refunded prior to fulfillment and shipping but once the order has been fulfilled and/or shipped, no refunds will be issued. Due to the hazardous nature of our product, we are unable to accept returns. BVV™ Terpenes are botanically derived terpenes enhanced with "nature-identical" artificial flavors. These flavors boost the natural flavor profile of the terpenes, providing the user with a more pleasant vaping experience. In order to provide complete transparency and elicit customer confidence, all ingredients are disclosed in the technical data sheet. BVV™ Granddaddy Purple Safety Data Sheet BVV™ Granddaddy Purple Technical Data Sheet Granddaddy Purple (GDP) is a strain from California with purple blooms. It is a cross between Big Bud and Purple Urkle. The effects of this sweet, grape/berry flavored, powerful strain are both euphoric and soothing. In addition to feeling soothed, patients describe feeling tired, happy, and hungry. FRAGRANCE: Sweet, floral, earth EFFECT: Soothed, tired, hungry and a fusion of euphoria Storage Requirements: Keep in the original container, lid securely tightened and away from heat, open flames, sunlight, combustible materials, and hot surfaces. Store below 15℃ (60℉). Improper storage can cause terpenes to degrade. Dilution: Terpenes must be diluted prior to use for flavor and effect (1-5% by total volume). Terpenes are oil soluble and mix well with plant extracts, coconut oil, and more. Handle With Care: Can cause skin irritation, do not ingest PRIOR to dilution.
$10.00 - $150.00
BVV™ High Purity Lab Grade N-Pentane 99%
BVV™ High Purity Lab Grade N-Pentane 99% HAZMAT ITEMS ARE NON-REFUNDABLE. ALL SALES ARE FINAL (Note: Container style and color may vary) BVV™ High Purity Lab Grade n-Pentane 99% is a hydrocarbon that has properties that are similar to butanes and hexanes. Pentane is a non-polar solvent and refrigerant. Pentane is used for the extraction and eluting of distillates, concentrates, volatiles, and essential oils from plant materials. Pentane can be used with hydrocarbon extraction systems that extract herbal oils, botanical compounds and oils from plants. It is a colorless liquid and has a petroleum-like odor. N-Pentane SDS N-Pentane COA Chemical Formula: C5H12 Molecular Weight: 72.151 g·mol−1 CAS Registry Number: 109-66-0 Appearance Colorless Liquid Odor: Gasoline-like Density 0.6262 g/mL (20 °C) Boiling Point: 35.9°C /96.5 °F Solubility in water: 40 mg/L (20 °C) GHS Pictograms: GHS Signal Word: Danger GHS Hazard Statements: H225, H304, H336, H411 GHS Precautionary Statements P210, P261, P273, P301+P310, P331 UN Identification Number: 1265 Proper Shipping Name: Pentanes Transport Hazard Class: 3 Packing Group: II DOT Placard: What Is N-Pentane? N-Pentane, also known as normal pentane, is a straight-chain alkane hydrocarbon with the molecular formula C5H12. It is one of the isomers of pentane, a hydrocarbon that consists of five carbon atoms bonded together in a linear, unbranched chain. n-Pentane is called "normal" because its carbon atoms are arranged in a continuous, straight chain, without any branching. What Are The Properties Of N-Pentane? Here are some of the key properties of n-pentane: Physical State: At room temperature and standard atmospheric pressure, n-pentane is a colorless, clear, and highly flammable liquid. Odor: It has a gasoline-like or organic solvent-like odor. Boiling Point: The boiling point of n-pentane is approximately 36.1 degrees Celsius (97 degrees Fahrenheit). This relatively low boiling point makes it useful in various applications. Density: The density of n-pentane at room temperature is about 0.626 grams per milliliter (g/mL). It is less dense than water, which has a density of 1 g/mL. Solubility: n-Pentane is sparingly soluble in water, which means it does not readily mix with water. This is because it is a nonpolar compound, and water is a polar solvent. However, it is highly soluble in nonpolar solvents and organic compounds. Flammability: n-Pentane is highly flammable and poses a fire hazard. It has a low flash point and can easily ignite when exposed to an open flame or heat source. Vapor Pressure: It has a relatively high vapor pressure at room temperature, meaning it readily evaporates into the air. Chemical Structure: As a straight-chain alkane, n-pentane consists of five carbon atoms bonded together in a linear fashion, with 12 hydrogen atoms bonded to these carbons. Molar Mass: The molar mass of n-pentane is approximately 72.15 grams per mole (g/mol). Reactivity: n-Pentane is relatively unreactive under normal conditions and does not readily undergo chemical reactions with common reagents. Uses: It is used as a laboratory solvent, industrial solvent, component in fuel blends, foam blowing agent, and as a chemical reagent in various applications. Safety Precautions: Due to its high flammability, proper safety precautions should be taken when handling n-pentane. It should be stored away from open flames, sparks, and heat sources. Environmental Impact: Like other hydrocarbons, the combustion of n-pentane releases carbon dioxide and other greenhouse gases into the atmosphere, contributing to climate change. n-Pentane is commonly employed in laboratory and industrial settings as a solvent, and its physical and chemical properties make it suitable for various applications. However, its flammability requires careful handling and storage to prevent accidents. What Is The Difference between N-Pentane and ISO-Pentane? n-Pentane and isopentane are two different structural isomers of pentane, each with distinct molecular arrangements. Here are the key differences between n-pentane and isopentane: Structural Arrangement: n-Pentane (Normal Pentane): n-Pentane has a linear, straight-chain structure with five carbon atoms connected in a continuous, unbranched chain. It is sometimes referred to as "normal" pentane due to its unbranched structure. Isopentane (2-Methylbutane): Isopentane has a branched-chain structure with one methyl (CH3) group branching off from the second carbon atom (C2) of the main carbon chain. This branching gives it its common name, "isopentane." Physical Properties: n-Pentane: n-Pentane is a clear, colorless liquid at room temperature and atmospheric pressure. It has a higher boiling point than isopentane and is less volatile. Isopentane: Isopentane is also a clear, colorless liquid at room temperature, but it has a lower boiling point compared to n-pentane. It is more volatile and evaporates more easily. Boiling Points: n-Pentane: The boiling point of n-pentane is approximately 36.1 degrees Celsius (97 degrees Fahrenheit). Isopentane: The boiling point of isopentane is lower, at approximately -11.7 degrees Celsius (11 degrees Fahrenheit). This lower boiling point makes it more suitable for certain applications. Applications: n-Pentane: n-Pentane is used as a laboratory solvent, in the formulation of industrial solvents, and as a component in gasoline and other fuels. Its relatively higher boiling point makes it less volatile and suitable for some applications where slow evaporation is desired. Isopentane: Isopentane is commonly used as a refrigerant and as a component in aerosol propellants, blowing agents for foam production, and as a solvent. Its lower boiling point and greater volatility make it useful in these applications. In summary, n-pentane and isopentane differ in their molecular structures, physical properties, boiling points, and applications. The choice between the two depends on the specific requirements of a given application, with n-pentane being less volatile and isopentane being more volatile. What Is The Structure Of N-Pentane? Pentane is an alkane with the chemical formula C5H12. It is a colorless, flammable liquid that is commonly used as a solvent and a fuel. The structure of pentane is a straight chain of five carbon atoms, with each carbon atom bonded to four hydrogen atoms. The carbon atoms in pentane are arranged in a tetrahedral geometry, with each carbon atom forming four bonds with other atoms. The hydrogen atoms are bonded to the carbon atoms in a single bond. What Is Pentane Used For? Pentane, both in its various isomeric forms (n-pentane and isopentane), has several industrial and commercial applications due to its properties as a hydrocarbon solvent and fuel component. Here are some common uses of pentane: Solvent: Pentane is used as a nonpolar solvent in various laboratory and industrial applications. It is particularly useful for dissolving oils, fats, waxes, and some organic compounds. Its low boiling point and relatively low toxicity make it suitable for these purposes. Foam Blowing Agent: Isopentane (also known as 2-methylbutane) is often used as a blowing agent in the production of polyurethane foams. When mixed with other chemicals, isopentane vaporizes and creates bubbles within the foam, leading to its expansion and formation. Fuel Component: Pentane, primarily in the form of isopentane, is used as a component in gasoline and other fuel blends. It enhances the octane rating of gasoline and helps reduce engine knocking, improving engine performance. Chemical Reagent: Pentane can serve as a chemical reagent in organic synthesis and research. It may be used as a reactant in some chemical reactions or as a medium for certain processes. Extraction: In laboratories, pentane is utilized for liquid-liquid extractions to separate compounds from mixtures based on differences in solubility. It is a common choice for extracting natural products and essential oils. Cleaning Agent: Pentane is employed for cleaning and degreasing purposes in industrial settings. It can effectively remove residues, contaminants, and oils from various surfaces and equipment. Refrigeration: Pentane has been used as a refrigerant in some applications, particularly in the form of isopentane. However, due to environmental concerns and regulations related to ozone depletion, its use as a refrigerant has diminished. Analytical Chemistry: In gas chromatography (GC), pentane is sometimes used as a carrier gas to transport samples through the GC column for analysis. Adhesives and Sealants: Some adhesive and sealant formulations may contain pentane as a solvent or propellant. Aerosol Propellants: Pentane, particularly isopentane, has been used as a propellant in aerosol spray products. Energy Production: In certain regions, pentane may be used as a fuel for heating and electricity generation, although this application is less common. It's important to note that while pentane has various industrial and commercial uses, safety precautions should be taken when handling it due to its flammable nature. Proper storage, ventilation, and safety measures are essential to minimize the risk of accidents. Additionally, environmental regulations and concerns have led to the exploration of alternative substances in some applications where pentane was traditionally used as a refrigerant or propellant. How Is Pentane Produced? Pentane is typically produced from petroleum through refining processes. It is a natural component of crude oil, and the separation and purification of pentane from crude oil involve various refining techniques. Here's an overview of how pentane is produced: Fractional Distillation: Crude oil is first subjected to fractional distillation in an oil refinery. This process separates the crude oil into different fractions based on their boiling points. Pentane, along with other hydrocarbons of similar boiling points, is separated from the crude oil in this initial distillation step. Fraction Separation: The fraction obtained in the distillation containing pentane and similar hydrocarbons is further separated in subsequent distillation columns. These columns are designed to separate hydrocarbons with similar boiling points, and pentane is separated from other hydrocarbons through a series of distillation steps. Purification: After the initial separation, the pentane fraction may still contain impurities and other hydrocarbons. To obtain high-purity pentane, additional purification steps are often employed. One common method is solvent extraction, where selective solvents are used to remove impurities. Adsorption and molecular sieves may also be used for purification. Final Processing: The purified pentane may undergo additional processing steps to meet specific product specifications or requirements. For example, it may be dried to remove any remaining water content. Packaging and Distribution: Once purified and processed, pentane is typically packaged into containers suitable for transportation and distribution. It may be distributed to various industries where it is used for its specific applications. Overall, the production of pentane is part of the larger petroleum refining process, and its availability depends on the composition of the crude oil and the specific refining techniques employed by the refinery. What Are The Hazards Of Pentane? Pentane, like other hydrocarbon compounds, poses certain hazards, especially when handled and used in industrial or laboratory settings. It's essential to be aware of these hazards and take appropriate safety precautions when working with pentane. Here are some of the hazards associated with pentane: Flammable: Pentane is highly flammable and can form explosive mixtures with air when its vapor concentration is within a specific range (approximately 1.5% to 7.8% by volume). This means that even a small spark or open flame can ignite pentane vapors, leading to fires or explosions. Health Hazards: Inhalation of pentane vapor can cause respiratory irritation, dizziness, headache, nausea, and, in severe cases, central nervous system depression. Prolonged exposure to pentane may lead to adverse health effects, including drowsiness, unconsciousness, and even asphyxiation. Irritant: Pentane can be a skin and eye irritant. Contact with the skin may cause irritation, redness, and dermatitis, particularly with prolonged or repeated exposure. Eye contact with pentane can result in irritation, redness, and discomfort. Environmental Impact: Pentane is a volatile organic compound (VOC) that can contribute to air pollution. When released into the atmosphere, it can react with other pollutants and contribute to the formation of ground-level ozone, which is harmful to human health and the environment. Asphyxiation Hazard: Pentane vapors can displace oxygen in poorly ventilated areas, creating an oxygen-deficient atmosphere. This can lead to asphyxiation if pentane is released in a confined space without proper ventilation. To use pentane safely, consider the following precautions: Work in well-ventilated areas or use exhaust systems to prevent the buildup of pentane vapors. Avoid open flames, sparks, and hot surfaces when working with pentane, and ensure that electrical equipment and wiring are explosion-proof in areas where pentane is used. Store pentane in approved containers away from heat, ignition sources, and incompatible materials. Use appropriate personal protective equipment (PPE), including safety goggles, gloves, and lab coats, when handling pentane. Have emergency response measures in place, including fire extinguishers and eyewash stations, when working with pentane. Follow safety data sheet (SDS) guidelines and procedures provided by the manufacturer or supplier of pentane. Educate and train personnel on the safe handling and storage of pentane. It's crucial to have a thorough understanding of the potential hazards associated with pentane and to implement appropriate safety measures to mitigate these risks. Always follow safety guidelines and regulations specific to your workplace or laboratory when working with pentane or any other hazardous chemicals. How Do I Use Pentane Safely? Using pentane safely is essential due to its flammable nature and associated hazards. Whether you're working with pentane in a laboratory, industrial setting, or any other environment, following proper safety procedures is crucial. Here are some steps to use pentane safely: Work in a Well-Ventilated Area: Always work in a properly ventilated area. Ensure that fumes and vapors can be effectively removed to prevent the buildup of pentane in the air. No Open Flames or Sparks: Avoid working near open flames, sparks, or other potential ignition sources. Pentane is highly flammable and can ignite easily. Use Appropriate Containers: Store pentane in approved containers designed for flammable liquids. These containers are typically designed to prevent leaks and resist fire. Keep Away from Heat Sources: Store pentane away from heat sources, including direct sunlight, radiators, and hot surfaces. Static Electricity: Ground yourself and any equipment that could generate static electricity. This helps prevent static sparks that could ignite pentane vapors. Wear Protective Gear: Use appropriate personal protective equipment (PPE), including safety goggles, gloves, and lab coats, to protect your eyes, skin, and clothing from contact with pentane. No Smoking or Eating: Do not smoke or eat while working with pentane. Keep food and beverages away from the work area. Emergency Equipment: Have safety equipment on hand, such as fire extinguishers, eyewash stations, and safety showers, in case of accidents or emergencies. Avoid Confined Spaces: Do not use pentane in confined spaces without proper ventilation. Pentane vapors can displace oxygen, leading to an oxygen-deficient atmosphere. Secure Containers: Ensure that containers are tightly sealed when not in use. Prevent spills and leaks. Safety Data Sheet (SDS): Familiarize yourself with the safety data sheet (SDS) provided by the manufacturer or supplier of pentane. SDS contains important information about the chemical's properties, hazards, and safe handling procedures. Training and Education: Train all personnel working with pentane on its safe handling, storage, and disposal. Ensure that they understand the hazards and know how to respond to emergencies. Labeling and Signage: Clearly label containers of pentane with appropriate warnings and hazard symbols. Use warning signs in areas where pentane is stored or used. Emergency Response: Develop and communicate emergency response plans, including evacuation procedures and fire safety protocols. Conduct regular drills to ensure that personnel are prepared. Proper Disposal: Dispose of pentane and any contaminated materials according to local, state, and federal regulations. Do not pour pentane down drains or dispose of it improperly. Regular Inspections: Periodically inspect equipment, storage areas, and containers for signs of damage or deterioration. Replace damaged equipment or containers promptly. By following these safety guidelines and practices, you can minimize the risks associated with pentane use and create a safer working environment. Always prioritize safety and be prepared to respond to potential emergencies involving pentane or other flammable chemicals.
$29.00 - $995.00
BVV™ High Purity Lab Grade Methanol 99%
BVV™ High Purity Lab Grade Methanol HAZMAT ITEMS ARE NON-REFUNDABLE. ALL SALES ARE FINAL (Note: Container style and color may vary) Spigots/Faucets are only compatible with 5 Gallon Plastic Jugs and must be purchased separately Trigger Sprayer is only compatible with 1QT and 1 Gallon sizes BVV™ High Purity Lab Grade Methanol is used to remove and extract terpenes, tannins, alkaloids, glycosides, lignans, and terpinoids from plants. It is used to extract bio-active, phenolic and polar compounds from medicinal plants. Methanol is a high purity solvent used to manufacture botanical solutions and is easily evaporated. Methanol is used in research and testing laboratories for phytochemical study, phytochemical analysis and chemical synthesis. Methanol is used to prepare methanol/water/acetic acid mixtures. BVV™ Methanol SDS BVV™ Methanol COA Chemical Formula: CH3OH Molecular Weight: 32.042 g·mol−1 CAS Registry Number: 67-56-1 Appearance Colorless Liquid Odor: Faint and similar to ethanol Density 0.792 g/cm3 Boiling Point: 64.7 °C /148.5 °F Solubility in water: miscible GHS Pictograms: GHS Signal Word: Danger GHS Hazard Statements: H225, H301, H302, H305, H311, H331, H370 GHS Precautionary Statements P210, P233, P235, P240, P241, P242, P243, P260, P264, P270, P271, P280, P301+P330+P331, P302+P352, P303+P361+P353, P304+P340, P305+P351+P338, P307+P311, P310, P311, P312, P337+P313, P361, P363, P370+P378, P403+P233, P405, P501 UN Identification Number: 1230 Proper Shipping Name: Methanol Transport Hazard Class: 3 Packing Group: II DOT Placard: What Is Methanol? Methanol, also known as methyl alcohol or wood alcohol, is a type of alcohol with the chemical formula CH3OH. It is the simplest alcohol, consisting of a methyl group (CH3) linked to a hydroxyl group (OH). Methanol is a colorless, flammable liquid with a slightly sweet odor. It is commonly used as an industrial solvent, antifreeze, fuel, and as a feedstock in the production of chemicals, plastics, and synthetic materials. Methanol can be synthesized from various sources, including natural gas, carbon monoxide, and biomass. It is considered a hazardous substance due to its toxicity when ingested, inhaled, or absorbed through the skin. Methanol is also used as an industrial and laboratory solvent and as a fuel in some types of racing cars and model engines. One important thing to note is that methanol is highly toxic when consumed, and even small amounts can be lethal. It should never be ingested, and safety precautions should be taken when handling this substance. What Is Methanol Used For? Methanol is used for a wide range of industrial, commercial, and laboratory applications. Some of its common uses include: Fuel: Methanol is used as an alternative fuel in some types of vehicles, particularly racing cars and model engines. It is also used in the production of biodiesel and as a fuel additive. Solvent: Methanol is a versatile solvent that can dissolve a variety of substances, making it useful in industries such as paint, varnish, and ink production. It is also used as a cleaning agent in laboratories and industrial settings. Antifreeze: Methanol is an essential component of some antifreeze formulations, where it helps prevent the freezing of engine coolant in cold temperatures. Chemical Intermediate: Methanol serves as a key building block in the production of various chemicals and materials, including formaldehyde, acetic acid, methyl methacrylate (used in plastics and coatings), and more. Fuel Cell Feedstock: Methanol can be used as a feedstock for the production of hydrogen, which can be used in fuel cells for electricity generation and other applications. Preservative: In the pharmaceutical and personal care industries, methanol is used as a preservative in some products. Denaturant: Methanol is added to industrial ethanol to make it unfit for consumption (denatured). This ensures that the ethanol cannot be used for drinking purposes and is used for industrial applications. Laboratory Reagent: Methanol is commonly used in laboratories as a reagent and solvent for various chemical experiments and analyses. Extraction: It is used in some extraction processes, such as the extraction of essential oils from plants. Energy Storage: Methanol is being explored as a potential energy carrier for energy storage and transportation, particularly in the form of methanol fuel cells. It's important to note that methanol is toxic to humans and should be handled with care. Ingesting or inhaling methanol vapors can be extremely dangerous and potentially fatal. Proper safety precautions and handling procedures are necessary when working with methanol. What Is The Structure of Methanol? Methanol, also known as methyl alcohol, has a simple chemical structure. Its molecular formula is CH3OH, which represents one carbon (C) atom, four hydrogen (H) atoms, and one oxygen (O) atom bonded together. Here's the structural formula of methanol: In this structure: The central carbon atom (C) is bonded to three hydrogen atoms (H) and one oxygen atom (O). The oxygen atom is bonded to the carbon atom through a single covalent bond (C-O). The remaining three hydrogen atoms are bonded to the carbon atom, completing its four covalent bonds. Methanol is a polar molecule due to the electronegativity difference between oxygen and hydrogen atoms, which results in a partial positive charge on the hydrogen atoms and a partial negative charge on the oxygen atom. This polarity gives methanol its unique chemical properties and makes it a versatile solvent in various applications. What are the Hazards of Methanol? Methanol, while commonly used in various industrial and laboratory applications, poses several hazards, primarily due to its toxic and flammable nature. Here are some of the hazards associated with methanol: Toxicity: Methanol is highly toxic to humans when ingested, inhaled, or absorbed through the skin. The toxic effects are primarily due to its metabolites, formaldehyde, and formic acid. Methanol poisoning can lead to symptoms such as headache, dizziness, nausea, vomiting, abdominal pain, and in severe cases, it can cause blindness, organ failure, and death. Flammability: Methanol is flammable and can form explosive mixtures in the air when its vapor concentration is within certain limits. It has a relatively low flashpoint, making it susceptible to ignition by heat, sparks, or open flames. Proper storage and handling precautions are essential to prevent fire hazards. Irritant: Methanol can be irritating to the eyes, skin, and respiratory tract. Contact with methanol vapor or liquid can lead to skin irritation, redness, and chemical burns. Inhaling methanol vapor can irritate the respiratory system and cause coughing and throat irritation. Environmental Impact: Methanol is harmful to the environment. Spills or releases of methanol can contaminate soil and water, posing a risk to aquatic life and ecosystems. It is important to handle and dispose of methanol responsibly to minimize its environmental impact. Incompatibility: Methanol should not be stored or transported in containers or systems that have previously held incompatible materials, as it can react with some substances and form hazardous compounds. Cumulative Exposure: Prolonged or repeated exposure to methanol vapor or mist over time can result in cumulative health effects, particularly on the central nervous system and the optic nerve. Ingestion Risk: Methanol has a sweet taste and is sometimes mistaken for ethanol (the alcohol found in alcoholic beverages). Accidental ingestion of methanol can occur, especially if it is stored in containers that are not clearly labeled. To safely handle methanol and mitigate these hazards, it is crucial to follow strict safety protocols, use appropriate personal protective equipment (PPE), store methanol in well-ventilated areas away from open flames, and provide proper training to personnel working with methanol. Emergency response plans and first-aid measures for methanol exposure should also be in place in case of accidents or spills. How Do I Use Methanol Safely? Using methanol safely is essential due to its toxic and flammable nature. Whether you're working with methanol in a laboratory, industrial setting, or other applications, here are some guidelines for safe handling: Personal Protective Equipment (PPE): Always wear appropriate PPE, including safety goggles, chemical-resistant gloves, a lab coat or chemical-resistant apron, and closed-toe shoes. Consider additional protective gear, such as a face shield, when handling large quantities or performing high-risk operations. Storage: Store methanol in well-ventilated areas away from heat sources, open flames, and direct sunlight. Use containers made of materials compatible with methanol, such as glass or approved plastic containers. Label containers clearly with the contents. Ensure proper labeling and hazard signage in storage areas. Handling: Handle methanol in a fume hood or well-ventilated workspace to minimize inhalation exposure. Do not use methanol near open flames, sparks, or heat sources. Avoid skin contact; wear gloves and lab coats to prevent skin exposure. Use a face shield or safety goggles to protect your eyes. Spill Response: Have spill kits and absorbent materials (e.g., spill pads, spill pillows) available for immediate use. In the event of a spill, ventilate the area, and contain the spill to prevent it from spreading. Wear appropriate PPE when cleaning up spills. Follow your workplace's spill response procedures and dispose of contaminated materials properly. Storage and Dispensing: Use safety containers designed for methanol when dispensing or transferring the liquid. Never use glassware or containers that have been used for other chemicals without thorough cleaning. Ensure proper grounding and bonding when transferring methanol to prevent static electricity buildup. Inhalation Exposure: Minimize inhalation exposure by working in a well-ventilated area or under a fume hood. If you suspect inhalation exposure, move to an area with fresh air and seek medical attention if symptoms persist. Ingestion Prevention: Do not eat, drink, or smoke in areas where methanol is handled. Avoid using containers or equipment that may be contaminated with methanol for food or beverage storage. Fire Safety: Methanol is flammable; keep it away from open flames, sparks, and heat sources. Use explosion-proof electrical equipment in areas where methanol vapors may be present. Emergency Response: Familiarize yourself with the location of safety showers, eyewash stations, fire extinguishers, and emergency exits. Know the location of first-aid supplies and procedures for methanol exposure. Training and Education: Ensure that personnel handling methanol are properly trained in its safe handling, storage, and emergency response procedures. Waste Disposal: Dispose of methanol waste in accordance with local, state, and federal regulations for hazardous waste disposal. Always follow your workplace's safety protocols and consult with safety officers or supervisors for specific safety procedures related to methanol handling in your environment. Regular safety training and awareness are essential to prevent accidents and protect your health when working with methanol.
$24.00 - $1,600.00
BVV™ Terpenes Lemon OG
BVV™ Terpenes Lemon OG All sales are final. Orders can be refunded prior to fulfillment and shipping but once the order has been fulfilled and/or shipped, no refunds will be issued. Due to the hazardous nature of our product, we are unable to accept returns. BVV™ Terpenes are botanically derived terpenes enhanced with "nature-identical" artificial flavors. These flavors boost the natural flavor profile of the terpenes, providing the user with a more pleasant vaping experience. In order to provide complete transparency and elicit customer confidence, all ingredients are disclosed in the technical data sheet. BVV™ Lemon OG Safety Data Sheet BVV™ Lemon OG Technical Data Sheet Lemon OG is a strain with a citrus flavor profile with sweet and sour notes. It has an effect of elevating mood, relaxation, and improving focus. Storage Requirements: Keep in the original container, lid securely tightened and away from heat, open flames, sunlight, combustible materials, and hot surfaces. Store below 15℃ (60℉). Improper storage can cause terpenes to degrade. Dilution: Terpenes must be diluted prior to use for flavor and effect (1-5% by total volume). Terpenes are oil soluble and mix well with plant extracts, coconut oil, and more. Handle With Care: Can cause skin irritation, do not ingest PRIOR to dilution.
$10.00 - $150.00
BVV™ Terpenes Blue Dream
BVV™ Terpenes Blue Dream All sales are final. Orders can be refunded prior to fulfillment and shipping but once the order has been fulfilled and/or shipped, no refunds will be issued. Due to the hazardous nature of our product, we are unable to accept returns. BVV™ Terpenes are botanically derived terpenes enhanced with "nature-identical" artificial flavors. These flavors boost the natural flavor profile of the terpenes, providing the user with a more pleasant vaping experience. In order to provide complete transparency and elicit customer confidence, all ingredients are disclosed in the technical data sheet. BVV™ Blue Dream Safety Data Sheet BVV™ Blue Dream Technical Data Sheet BVV™ Food Grade Certificate Blue Dream is a crossed strain to create a hybrid that is popular for daytime use. Blue Dream delivers a soothing, creative euphoria but without a resting effect. Fragrance Sweet, berry, earth Effect Euphoric, energizing, the most popular strain for elevating one's feelings Storage Requirements: Keep in the original container, lid securely tightened and away from heat, open flames, sunlight, combustible materials, and hot surfaces. Store below 15℃ (60℉). Improper storage can cause terpenes to degrade. Dilution: Terpenes must be diluted prior to use for flavor and effect (1-5% by total volume). Terpenes are oil soluble and mix well with plant extracts, coconut oil, and more. Handle With Care: Can cause skin irritation, do not ingest PRIOR to dilution.
$10.00 - $150.00
BVV™ Extract Thinner *Compare to True Terpenes Viscosity
BVV™ Extract Thinner All sales are final. Orders can be refunded prior to fulfillment and shipping but once the order has been fulfilled and/or shipped, no refunds will be issued. Due to the hazardous nature of our product, we are unable to accept returns. BVV™ Extract Thinner is a diluent made from natural terpenes. It does not contain PG, VG, PEG, MCT, Squalane, Squalene, Coconut oil, Triethyl Citrate, or Vitamin E Acetate. Our Extract Thinner will combine with your terpenes and oil and is formulated to minimize flavor and aroma impact. Oure Extract Thinner is not a thickening nor cutting agent and not recommended to be used with CBD. This product is designed to be used with winterized extracts. It is a clear liquid with a faint, odor that will minimally contribute to the aroma and flavor. In order to provide complete transparency and illicit customer confidence, all ingredients are disclosed. INGREDIENTS: Phytol, Beta-Caryophyllene, D-Limonene, Farnesol and Nerolidol Dilution Use Instructions: First infuse your terpene strain or flavor into your winterized extract. Typically 1-5% by volume. Then to use the Extract thinner add 1-3% by Total Volume to thin the extract. Made in the USA by cGMP facilities ISO 9001:2015 Shelf Life: 3 Years Storage Requirements: Keep in the original container, lid securely tightened and away from heat, open flames, sunlight, combustible materials, and hot surfaces. Store in a cool dry place. Improper storage can cause terpenes to degrade.
$16.00 - $280.00
BVV™ 6CFM Single Stage Spark Free Pump
BVV™ 6CFM Single Stage Spark Free Pump This is the brand new BVV™ 6CFM Single Stage Spark Free Pump. It is is a reliable and efficient pump that is designed for use in hazardous locations without the risk of ignition. Please Refer to these charts for vacuum specifications at altitude and conversions: Vacuum at Altitude Chart Vacuum Conversion Chart Key Features: Spark Free Operation 1/4" and 3/8" Flared connections. Internal Check Valve Oil Mist Filter Cap Larger Oil Reservoir for longer Oil life Lightweight Rubber Feet for noise dampening Reliable, Economical and Efficient. Specifications No. of Stages: 1 Free Air Displacement: 6CFM Voltage 110v / 60Hz Ultimate Vacuum 75 Micron Motor Speed 2880 Oil Capacity 650ml Weight 19LB Intake Connection 1/4" SAE, 3/8" SAE Pump Warranty Information Customers using solvents such as stabilization resins (MinWax™, Gator Venom™ etc.), alcohol and other polar solvents must use the vacuum pumps in conjunction with a cold trap for evacuations in excess of 5 minutes. (Excludes Cactus Juice™) If the consumer is using the pump for prolonged periods of time exceeding 5 minutes we require that a cold trap is used or the pump warranty is void. These stabilization resins have the ability to break down the internal components of the pump that are plastic resulting in a seized motor voiding all warranties. When evacuation exceeds 5 minutes these solvents begin to vaporize and then re-condense in the vacuum pump reservoir. Once enough solvent re-condenses in the pump displacing the oil the plastic internal components may begin to warp, melt or seize. The use of a cold trap will condense the vapors prior to making their way to the vacuum pump preventing pump damage due to excessive use. Furthermore, Minwax Wood Hardener™ is not to be used with any vacuum pumps, EVER. (A seized motor will result within the first use.) To prevent these issues from happening to your process, change the Oil after each vacuum pump use, Even if the use time is only 5min.
$200.00$160.00
Harvest Right Oil Free Pump
Harvest Right Oil Free Pump What is Included: One oil free pump. The oil free vacuum pump can be used with any size freeze dryer. They are quiet, fast, and easy to use. The Harvest Right oil free vacuum pumps do not require oil changes and do not require regular user maintenance. Overview The oil free vacuum pump can be used with any size freeze dryer. They are quiet, fast, and easy to use. The Harvest Right oil free vacuum pumps do not require oil changes and do not require regular user maintenance. Technical Specification CFM 7 Voltage Standard 110V. 60Hz Plug US 110V Intake Port 3/4 JIC flare Dimensions 19″ high x 10″ deep x 10″ wide Weight 42lbs
$1,695.00
BVV™ Terpenes GSC
BVV™ Terpenes GSC All sales are final. Orders can be refunded prior to fulfillment and shipping but once the order has been fulfilled and/or shipped, no refunds will be issued. Due to the hazardous nature of our product, we are unable to accept returns. BVV™ Terpenes are botanically derived terpenes enhanced with "nature-identical" artificial flavors. These flavors boost the natural flavor profile of the terpenes, providing the user with a more pleasant vaping experience. In order to provide complete transparency and elicit customer confidence, all ingredients are disclosed in the technical data sheet. BVV™ GSC Safety Data Sheet BVV™ GSC Technical Data Sheet Girl Scout Cookies or GSC is a California original and is a hybrid of OG Kush and Durban Poison. GSC has a pungent, sweet, earthy aroma and is described as giving feelings of happiness, soothing, creativity, and euphoria. Fragrance Floral, earth, spicy, sweet, pine Effect Mood elevating, Relaxing, Improves sleep, Improves focus Storage Requirements: Keep in the original container, lid securely tightened and away from heat, open flames, sunlight, combustible materials, and hot surfaces. Store below 15℃ (60℉). Improper storage can cause terpenes to degrade. Dilution: Terpenes must be diluted prior to use for flavor and effect (1-5% by total volume). Terpenes are oil soluble and mix well with plant extracts, coconut oil, and more. Handle With Care: Can cause skin irritation, do not ingest PRIOR to dilution.
$10.00 - $150.00
BVV™ Terpenes Blueberry AK
BVV™ Terpenes Blueberry AK All sales are final. Orders can be refunded prior to fulfillment and shipping but once the order has been fulfilled and/or shipped, no refunds will be issued. Due to the hazardous nature of our product, we are unable to accept returns. BVV™ Terpenes are botanically derived terpenes enhanced with "nature-identical" artificial flavors. These flavors boost the natural flavor profile of the terpenes, providing the user with a more pleasant vaping experience. In order to provide complete transparency and elicit customer confidence, all ingredients are disclosed in the technical data sheet. BVV™ Blueberry AK Safety Data Sheet BVV™ Blueberry AK Technical Data Sheet BVV™ Food Grade Certificate Blueberry AK As the name suggests, Blueberry AK is a hybrid strain that combines the indica-dominant Blueberry with the sativa-dominant AK-47, both popular and potent strains in their own right. Blueberry AK has a strong musky odor with undertones of berry, and flavors ranging from sweet Kush to the more peppery taste of the AK. The effects of this hybrid are both relaxing and upbeat, often inducing a case of the giggles, and people have used it to treat anxiety, depression, and pain. Fragrance Earth, Citrus, Sweet Effect Mood Elevating, Relaxation, Eases Minor Pain. Storage Requirements: Keep in the original container, lid securely tightened and away from heat, open flames, sunlight, combustible materials, and hot surfaces. Store below 15℃ (60℉). Improper storage can cause terpenes to degrade. Dilution: Terpenes must be diluted prior to use for flavor and effect (1-5% by total volume). Terpenes are oil soluble and mix well with plant extracts, coconut oil, and more. Handle With Care: Can cause skin irritation, do not ingest PRIOR to dilution.
$10.00 - $150.00
BVV™ Terpenes Durban Poison
BVV™ Terpenes Durban Poison All sales are final. Orders can be refunded prior to fulfillment and shipping but once the order has been fulfilled and/or shipped, no refunds will be issued. Due to the hazardous nature of our product, we are unable to accept returns. BVV™ Terpenes are botanically derived terpenes enhanced with "nature-identical" artificial flavors. These flavors boost the natural flavor profile of the terpenes, providing the user with a more pleasant vaping experience. In order to provide complete transparency and elicit customer confidence, all ingredients are disclosed in the technical data sheet. BVV™ Durban Poison Safety Data Sheet BVV™ Durban Poison Technical Data Sheet BVV™ Food Grade Certificate BVV™ Terpenes Durban Poison Durban Poison is a pure sativa known for its energy-giving, uplifting, creative effects. It has a sweet smell and a sweet, earthy, pine flavor. Fragrance Sweet, Sour, Earth, Pine, Citrus Effect Productive, Creative Energy, Focusing Strain Storage Requirements: Keep in the original container, lid securely tightened and away from heat, open flames, sunlight, combustible materials, and hot surfaces. Store below 15℃ (60℉). Improper storage can cause terpenes to degrade. Dilution: Terpenes must be diluted prior to use for flavor and effect (1-5% by total volume). Terpenes are oil soluble and mix well with plant extracts, coconut oil, and more. Handle With Care: Can cause skin irritation, do not ingest PRIOR to dilution.
$10.00 - $150.00
BVV™ Terpenes Gelato
BVV™ Terpenes Gelato All sales are final. Orders can be refunded prior to fulfillment and shipping but once the order has been fulfilled and/or shipped, no refunds will be issued. Due to the hazardous nature of our product, we are unable to accept returns. BVV™ Terpenes are botanically derived terpenes enhanced with "nature-identical" artificial flavors. These flavors boost the natural flavor profile of the terpenes, providing the user with a more pleasant vaping experience. In order to provide complete transparency and elicit customer confidence, all ingredients are disclosed in the technical data sheet. BVV™ Gelato Safety Data Sheet BVV™ Gelato Technical Data Sheet Gelato This hybrid strain is named for its dessert-like aroma. A blend of Sunset Sherbet and Thin Mint Girl Scout Cookies, Gelato is a potent deliverer of restfulness and euphoria. Sweet, pungent, flowery scents bring creativity. Also known as “Larry Bird.” Fragrance Sweet, Pungent, Berry-Like, Creamy Effect Soothing, Euphoric, Happy, Giggly Storage Requirements: Keep in the original container, lid securely tightened and away from heat, open flames, sunlight, combustible materials, and hot surfaces. Store below 15℃ (60℉). Improper storage can cause terpenes to degrade. Dilution: Terpenes must be diluted prior to use for flavor and effect (1-5% by total volume). Terpenes are oil soluble and mix well with plant extracts, coconut oil, and more. Handle With Care: Can cause skin irritation, do not ingest PRIOR to dilution.
$10.00 - $150.00
BVV™ Terpenes GG4
BVV™ Terpenes GG4 All sales are final. Orders can be refunded prior to fulfillment and shipping but once the order has been fulfilled and/or shipped, no refunds will be issued. Due to the hazardous nature of our product, we are unable to accept returns. BVV™ Terpenes are botanically derived terpenes enhanced with "nature-identical" artificial flavors. These flavors boost the natural flavor profile of the terpenes, providing the user with a more pleasant vaping experience. In order to provide complete transparency and elicit customer confidence, all ingredients are disclosed in the technical data sheet. BVV™ GG4 Safety Data Sheet BVV™ GG4 Technical Data Sheet GG#4 is an award-winning hybrid strain. It is potent and indica dominant. Pungent, earthy, pine aromas accompany heavy, happy soothing effects. This strain is the offspring of Chem’s Sister, Sour Dubb, and Chocolate Diesel, and it will have you feeling “glued” to the couch. Fragrance Earth, Pine, Fuel Effect Euphoric, Soothing, Heavy and Extreme Couch-lock Storage Requirements: Keep in the original container, lid securely tightened and away from heat, open flames, sunlight, combustible materials, and hot surfaces. Store below 15℃ (60℉). Improper storage can cause terpenes to degrade. Dilution: Terpenes must be diluted prior to use for flavor and effect (1-5% by total volume). Terpenes are oil soluble and mix well with plant extracts, coconut oil, and more. Handle With Care: Can cause skin irritation, do not ingest PRIOR to dilution.
$10.00 - $150.00
BVV™ Terpenes Blueberry Afgoo
BVV™ Terpenes Blueberry Afgoo All sales are final. Orders can be refunded prior to fulfillment and shipping but once the order has been fulfilled and/or shipped, no refunds will be issued. Due to the hazardous nature of our product, we are unable to accept returns. BVV™ Terpenes are botanically derived terpenes enhanced with "nature-identical" artificial flavors. These flavors boost the natural flavor profile of the terpenes, providing the user with a more pleasant vaping experience. In order to provide complete transparency and elicit customer confidence, all ingredients are disclosed in the technical data sheet. BVV™ Blueberry Afgoo Safety Data Sheet BVV™ Blueberry Afgoo Technical Data Sheet BVV™ Food Grade Certificate Blueberry Afgoo Blueberry Afgoo is an relaxing strain that was created by crossing Blueberry and Afgoo. The Blueberry Afgoo terpene profile has a pleasing palette of pine, skunk, and berry. Fragrance Piney, Skunky, Berry Effect Promotes Relaxation, Improves Sleep, Stress Relief. Storage Requirements: Keep in the original container, lid securely tightened and away from heat, open flames, sunlight, combustible materials, and hot surfaces. Store below 15℃ (60℉). Improper storage can cause terpenes to degrade. Dilution: Terpenes must be diluted prior to use for flavor and effect (1-5% by total volume). Terpenes are oil soluble and mix well with plant extracts, coconut oil, and more. Handle With Care: Can cause skin irritation, do not ingest PRIOR to dilution.
$10.00 - $150.00
Cascade CVO-2 Vacuum Oven
Cascade CVO-2 Vacuum Oven (Oven Only) This item carries up to a 1-2 week lead time. Model CVO-2 offers incredible temperature stability for vacuum drying and purging of pharmaceuticals, botanicals, slurries, or any temperature sensitive material. This vacuum oven liberates solvents, water, and other unwanted compounds in small batch, R&D and lab environments. NRTL Certified. CVO-2 Vacuum Oven Features NRTL Certified by TUV 5 shelves (11.5″W x 19″D) in a flexible configuration. Shelves are stackable and removable Stable temperature control. Digital temperature readout with temp sensor INSIDE the oven Solvent resistant BUNA door gasket Bright LED lights in window for visibility of sensitive material Digital vacuum gauge reads in inches of mercury Simple, set-point control Smooth, quarter-turn vacuum and vent valves Rear KF-25 port allows for rapid MAXEVAP purging or running feedthroughs inside oven for monitoring 120V (220V available) Quality Tempered Rated Glass NGI-US to ANSI Z97.1.2007 156CFR/201 11 SGCC -2577 ½ UA Adjustable leveling feet ensure oven sits solid and level in the workspace CVO-2 Connections 3/8″ Barb for Vacuum Pump 1/4″ Barb for Venting (N2 Connection OK) KF-25 Port for feedthroughs or MAXEVAP Connection Kit Need A Complete CVO-2 Vacuum Package? Cascade has taken the guess work out of pairing the right vacuum oven with the proper pump. We offer two complete CVO-2 vacuum oven packages with everything you need for vacuum drying. Both packages feature clean, quiet, Agilent oil-free scroll pumps. The CVO-2 STANDARD Package is an ideal package for vacuum drying or purging requiring a steady, gentle, non-turbulent purge. The CVO-2 PRO Package is ideal for higher thru-put, faster purge times pulling deeper vacuum. CVO-2 Comes In Low & High Temp Models Low & High Temp Specifications CVO-2 (Low Temp) Temperature Processing Range -3ºC to 121°C (26°F to 250°F) Temperature Uniformity +/- 1ºC at 40.5°C (+/- 1.5°F at 105°F) Temperature Stability +/- 0.5°C at 40.5°C (+/- 0.4 at 105°F) CVO-2-HT (High Temp) Temperature Processing Range Up to 220°C (428°F) Temperature Uniformity +/- 6.5% of setpoint The Cascade Difference Vacuum ovens have been around for decades. Basic vacuum ovens are mass-produced and sold by many large scale laboratory equipment distributors. But there are key differences between Cascade and other inexpensive, often imported vacuum ovens. Exceptional Temperature Control & Stability The Cascade CVO-2 uses a unique control logic not found in most lab grade vacuum ovens. The temperature probe is INSIDE the oven, which minimizes temperature overshoot and delivers best-in-class temperature stability and uniformity particularly in the low temperature ranges. Accurate, stable temps throughout the CVO-2 eliminate hot and cold spots, making accurate use of every inch of shelf space. Independent Over-temp Failsafe Protection The Cascade Sciences CVO-2 is equipped with a heating cutoff system that will automatically stop power to the heaters when the oven shelf temps exceed 200°C or 392°F. This protection system will provide peace of mind for overnight processing or unattended vacuum bake outs. NRTL Certification #U8 170464972 077. No Extra cost. The CVO-2 Vacuum Oven comes certified by the Nationally Recognized Test Lab, TUV. This certification is a requirement by many municipalities. CAN/CSA-C22.2 No. 61010-1:2012 +UPD No. 1:2015-07 + UPD No. 2:2016-04 CAN/CSA-C22.2 No. 61010-2-010:2015 UL 61010-1:2012/R:2016-04 UL 61010-2-010:2015 EN 61010-1:2010 EN 61010-2-010:2014 Rigorous Quality Assurance in an ISO Certified, USA Manufacturing Facility Cascade Sciences manufactures our ovens in Oregon, USA. We are proud of our ISO 9001 Certification/Accreditation. Each oven completes a series of quality assurance procedures before shipment: Chambers are vacuum tested after welding for vacuum integrity Electrical & mechanical safety is thoroughly tested in compliance with TUV requirements Functional testing verifies user settable items consistent with most lab protocols/usage models Temperature verification includes calibration & temp chamber uniformity following ASTM standards Units are cleaned and packed in ISTA tested, certified packaging materials Digital Vacuum Gauge The digital vacuum gauge installed on the CVO-2 is factory default set to read in inches of mercury (“Hg) with a scale of 0 – 29.9”Hg. Change the unit of vacuum measurement to read in a wide variety of units from mmHg, bar psi, kPa, cm2, mmH20. Zero out the vacuum gauge to calibrate for just above sea level adjustments. Equipped for Inert Gas Backfill. Built-In Safety Relief Introduce inert gasses such as nitrogen, argon, helium, etc. as part of your process via the 1/4″ rear vent barb. The maximum backfill pressure is 15PSI. In an overpressure situation, a simple, built-in safety relief allows gasses to escape via a spring loaded tempered window. Flexible Pumping / Feedthru Connection Ports The CVO-2 ovens offer two different vacuum oven connection points. The standard connection is a 3/8″ dia barb located at the rear of the oven. It is connected to the vacuum valve level on the front control panel. For even faster evaporation, purging or drying consider upgrading to the MAXEVAP connection kit. The MAXEVAP connection kit secures to the oven’s rear 1″ dia KF-25 port located on the back center of the chamber. The MAXEVAP connection never reduces flow by continuing with 1” diameter vacuum rated clear lines, a 1” dia KF-25 side mounted vacuum valve and KF-25 fittings and hardware. This KF-25 port can also be used to run temperature feedthroughs, or monitoring sensors inside the vacuum chamber during processing. Stackable Shelf Design For Maximum Temperature Conduction Under vacuum, there is no air inside a vacuum oven. Temperatures are achieved by a process of conduction and radiation to move temperatures into the product inside the oven. Cascade’s stackable shelf design makes the most of this opportunity by making the chamber longer and narrower, rather than square and supplies stackable shelves in multiple height configurations to allow for the fastest, most uniform transfer of heat. Ergonomically Designed, Easy Quarter-Turn Valves For anyone that has struggled with consistently turning the small, round, low-quality vacuum/vent valves, relief is in sight. You will love our large, quarter-turn vacuum/vent valves. Your wrists will thank you! ANSI Rated Tempered Glass + USA Made Steel Cascade ovens are made in Oregon, USA with high quality materials. Our glass is NGI-USA Tempered and certified to ANSI Z97.1.2007 16CFR / 201 11. Our door handles are rugged brushed steel, not plastic. Our vacuum vessels are constructed with American made steel. We’ve tried lower cost, imported steel, but over time, vacuum chambers made of lesser quality/lower tolerance material cannot withstand the flex and pressure changes of vacuum pumping/venting/purging. This can deteriorate vacuum integrity and the oven will lose its ability to hold vacuum. Door Gasket Options – Ideal For Your Process Cascade’s vacuum ovens come standard with a solvent resistant BUNA door gasket. For higher temp applications, we offer a cured Silicone gasket as well. Ask us about the variety of door gaskets we can supply based on your application: Silicone, BUNA, Viton, Fluorosilicone. Gaskets will eventually wear out. It’s ideal to keep a few spares on hand. Model CVO-2 Vacuum Oven Specifications: Capacity Volume 1.67 Cu Ft (47.2 L) Interior 12″W x 20″D x 12″H (305mm x 508mm x 305mm) Exterior 18.8″W x 24.5″D x 24.5″H (478mm x 622mm x 622mm) Product Weight 148 lbs (67.1 kgs) Temperature Temperature Range -3ºC to 121°C (26°F to 250°F) Temperature Uniformity +/- 1ºC at 40.5°C (+/- 1.5°F at 105°F) Temperature Stability +/- 0.5 at 40.5°C (+/- 0.4°F at 105°F) Vacuum Vacuum Valve 1/4 Turn Lever Vent Valve 1/4 Turn Lever Vacuum Gauge Digital. 0 to 29.9″Hg Temperature Controller Digital Set Point Accurate Within .5ºC (1°F) Independent Overtemp Failsafe Ports (Rear) Vacuum 3/8″ Barb Vent 1/4″ Barb Auxiliary KF-25 Port Inert Gas Introduction Use 1/4″ Vent Barb 15 psi max inlet pressure Power Options 110V – 120V / 1ph / 6A 50/60Hz (Cord Included) NEMA 5 – 15 Power Outlet Full Power 2456 BTU/hr *(220V Optional) Shelving Includes 5 shelves in a flexible configurationShelves are stackable and removable1″ High = 1 each2″ High = 2 each3″ high = 2 each Surface Area 11.5″W x 19″D Weight Capacity 50 lbs (22.7 kgs) Door Interior Lighting LED Strips (Rated to 150°C) Glass Window Tempered NGI-US to ANSI Z97.1.2007 Gasket Type 12″ x 12″ Solvent Resistant BUNA Standard Gasket Rated to 105°C (221°F) Gasket Options: High Temp Silicone Option rated to 30°C (446°F)Viton Option rated to 205°C (401°F) Shipping & Weights Unit Weight 179 lb (81.2 kg) Shipping Weight 218 lbs (99 kg) Shipping Dimensions 33″L x 33″W x 47″D (Class 85) Product Certifications: NRTL TUV #U8 170464972 077CAN/CSA-C22.2 No. 61010-1:2012+ UPD No. 1:2015-07 + UPD No. 2:2016-04CAN/CSA-C22.2 No. 61010-2-010:2015UL 61010-1:2012/R:2016-04UL 61010-2-010:2015EN 61010-1:2010EN 61010-2-010:2014 Warranty: 1 Year (Gaskets not included) *Temperature performance specifications are preformed in empty ovens. Performance can vary in ovens containing product. NTRL Certification PDF Manual Vacuum Pressure Chart Vacuum Gauge Manual Calibration
$6,889.00
Ashless Filter Papers - 350MM - Quantitative
Ashless Filter Papers - 350MM - Quantitative Quantitative and qualitative filter papers provide laboratory grade filtration for extraction systems and are specifically used in combination with a Buchner funnel to remove fats, waxes and any other unwanted contaminants from your solution. These filter papers are used in the pre-processing stage of short path distillation to clean up the material prior to processing. Key Features: ISO 9001 Approved Manufactured from alpha-cellulose and cotton linters High Purity and low background Consistent performance Whatman equivalent quality Pre-Cut for ease of use Specifications: Classification Quantitative Sizes Available: AFP-1 11um - Medium AFP-4 20um - Fast Quantity per Pack 100 Diameter 350mm (13.78")
$74.00 - $81.00
MAXTRAP105 -105°C Vacuum Cold Trap, 120V
MAXTRAP105 -105°C Vacuum Cold Trap, 120V Cascade’s MAXTRAP105 is not an ordinary lab-grade cold trap. Cascade has integrated features necessary for time-sensitive, high-throughput, production-focused vacuum purging or drying applications. MAXTRAP105 Cold Trap Includes: Cascade’s COLDWELL 304 Stainless Steel Trap Insert (Patent pending baffle system) 3 Quart Capacity (2839 ml) Viton Gasket for Vacuum Integrity Labconco -105°C Refrigerated Base Green CFC / HFC Free Refrigerants Power Cord 3mm Neoprene Insulator Cap Requires 800ml (~ 3.5 cups) of a transfer fluid such as ethanol. Not Included. Cascade recommends: ethanol, glycol, cryo-cool fluids Quality Made in USA 1 Year Warranty Connection Lines and hardware: 4′ of 1″ Diameter Vacuum Tubing with KF-25 Flanges on each side. KF-25 clamps, centering rings for the connection tube MAXTRAP Tips: Safety At very cold temperatures, solvents and even oxygen can re-condense back into liquid. This is potentially explosive. Liquid oxygen is a light blue color and can condense into a cold trap if a pump has sucked air through the trap when the trap is very cold. Always follow your standard operating procedures and safety guidelines. Don’t Stop: Keep Processing while trap is being reclaimed, cleaned, refreshed Cold traps can become full or the captured material freezes and blocks flow. For high moisture, outgassing, 24 hour processing/vacuum purging consider adding a second, spare COLDWELL trap. The secondary COLDWELL can be dropped into place so processing continues while the full trap is cleaned, defrosted. Quick Start Up Tips: Remove shipping foam from reservoir bottom prior to use Fill reservoir with 800ml (+/-3.5 cups) ethanol to marked line Monitor ethanol levels inside reservoir Allow at least 30 mins for trap to cool Keep side vents clear. Allow at least 4″ for airflow Monitor interior of stainless trap for clogging Short tube – attach to vacuum pump Tall tube – attach to vacuum oven MAXTRAP105 Differences: The key to quality cold trap performance is: time, surface area, and temperature. Time: Most cold traps have very narrow inlets and outlets, slowing down your process. Not Cascade’s MAXTRAP105! Full KF25 inlet and outlet connections never reduce flow. Surface Area: Most cold traps have glass or a smaller surface area to collect the matter your vacuum pump would otherwise ingest. Cascade’s MAXTRAP105 surface area is a patent pending series of filter baffles inside the COLDWELL stainless trap. Specifications Coldwell Stainless Trap KF25 Inlet & Outlet 3 Quart Capacity (2839 mliters) Viton Gasket Neoprene Insulator Cap Labconco -105°C Mechanical Base 115V / 1ph / 3 AMP (60Hz) Cord Included CFC / HCFC Free Refrigerants Dimensions inches 24.1 W x 23.9 D x 12.6 H cm 34.3 x 59.7 x 30.5 *Requires approximately 800ml (~ 3.5 cups) of transfer fluid(ethanol, glycol, cryo-cool fluids) Connections 1 each 4′ KF-25 flanged vacuum rated line 1 each KF-25 Centering Ring 1 each KF-25 Clamp Weight COLDWELL Stainless Trap: 14 lbs Mechanical Base: 139 lbs Shipping Weight: 190 lbs Additional Resources: Download Specs Download Supplemental Manual NTRL Certifications -105C Refrigerated Base Safety Certification
$9,950.00
Pure-Flo® B81 Supreme Activated Bleaching & Decolorizing Bentonite for Edible Oils *FDA-GRAS (Compares to T-5™)
Pure-Flo® B81 Supreme Moderately Activated Bentonite Clay for Bleaching & Decolorizing Edible Oils pH:4.4 Pure-Flo® B81 Supreme Offers fats and oils processors surface modified performance at the best value. Excellent for oils with moderate color and chlorophyll levels. Supreme B81 adsorbent has been activated using a proprietary Surface Modification Technology (SMT). Pure-Flo® Supreme B81 Data Sheet.pdf B81 Supreme Safety Data Sheet • Excellent metals adsorption characteristics (P, Ca, Fe, Mg, Ni, etc.)• Removes color bodies from a variety of oils and effectively eliminates chlorophyll from vegetable oils• Removes soaps and phospholipids• Minimizes free fatty acid rise during bleaching• Outstanding filtration characteristics, including long filtration cycles and lesspressure build up at cycle end ph:4.4 FDA GRAS (Generally Recognized as Safe) - This product is safe for processing food, as long as its not part of the end product being consumed. NSF- HACCP *Prior to down packing this product was certified Kosher & Hallal. It does not retain its certifications after down packing, Sorry BVV™ doesn't have an on staff Rabbi or Imam on site to re-establish those certifications. Note: Bulk Bags and Bulk sizes are non-stocked items and will be ordered as needed and carry a several weeks lead time and require a forklift or pallet jack
$20.00 - $2,250.00
Pure-Flo® Perform 5000 Highly Acid Activated Bleaching & Decolorizing Bentonite for Edible Oils *FDA-GRAS
Pure-Flo® Perform 5000 Highly Activated Bentonite Clay for Bleaching & Decolorizing Edible Oils pH: 2.7 Pure-Flo® Perform 5000 provides superior bleaching activity for demanding oils. Effective with all types of difficult-to-bleach oil. Pure-Flo® Perform 5000 Technical Data Sheet.pdf Perform 5000 Safety Data Sheet Excellent metals adsorption characteristics (P, Ca, Fe, Mg, Ni, etc.) Excellent Chlorophyll removal Excellent Red and Blue color body removal. Removes soaps and phospholipids Outstanding filtration characteristics, including long filtration cycles and less pressure build up at cycle end. ph:2.7 FDA GRAS (Generally Recognized as Safe) - This product is safe for processing food, as long as its not part of the end product being consumed. NSF- HACCP *Prior to down packing this product was certified Kosher & Hallal. It does not retain its certifications after down packing, Sorry BVV™ doesn't have an on staff Rabbi or Imam on site to re-establish those certifications. Note: Bulk Bags and Bulk sizes are non-stocked items and will be ordered as needed and carry a several weeks lead time and require a forklift or pallet jack
$20.00 - $2,250.00
Huber CC-902 460V with Pilot ONE
Huber CC-902 460V with Pilot ONE (Please Note: There is up to 3 weeks Shipping lead time) The Refrigeration Bath Circulators are created to control the temperature of externally connected. Applications are: photometers, refractometers, viscometers, double-jacketed reaction vessels and autoclaves. the units can be used, for determining the freezing point, for deep temperature calibration, for petroleum tests, for temperature control of measuring devices and experimental setups as well as for materials testing and quality control. The new multi-touch controller Pilot ONE offers a brilliant 5.7" touchscreen with graphic functions and a comfortable navigation menu. All important operating parameters and temperature values are neatly displayed on the touchscreen. Thanks to the new favourites menu, the one-click operation and the integrated technical glossary the operation is very easy, just like on a smartphone. Integrated USB and Ethernet ports allows connection to a PC or network, e.g. for remote control or data transmission. Pilot ONE controller with Plug & Play technology Precise temperature control 5.7" touchscreen and comfortable menu navigation Overtemperature and low level protection Safety class III/FL (DIN 12876) Powerful pressure/suction pump Programmer with calendar and clock functions 2-point calibration RS232 interface and Pt100 connection Download Data Sheet Click Here 3 Year Warranty Register Please observe the notes on installation and/or the space requirements of our products. General information & Temperature Controller Temperature range -90...200 °C Temperature stability ±0.02 °C ±0.02 °C Controller Pilot ONE (E-grade "Basic") Pilot ONE (E-grade "Basic") Safety class III / FL Protection class IP20 Dimensions (W x D x H) 550 x 600 x 911 mm | 21.65 x 23.62 x 35.87 inches Weight 151 kg | 332.96 pounds Heating / Cooling Capacity Heating capacity 1,8 kW Cooling capacity 100 20 0 -20 -40 -60 -80 °C1,2 1,2 1,2 1,1 0,9 0,6 0,2 kW Cooling machine air-cooled Refrigerant 1. stage R452A (A1, H280) (0,78 kg) Refrigerant 2. stage R508B (A1, H280) (0,46 kg) Circulation Pump Pressure pump max. 25 lpm ; 0.7 bar | 6.6 gpm ; 101.5 psi Suction pump max. 18.5 lpm ; 0.4 bar | 4.89 gpm ; 5.8 psi Pump Connection M16x1 AG male Permissible viscosity 50 mm²/s Connections Pt100 connection Pt100 Digital interface RS232, Ethernet, USB Device, USB Host Operating Data Permissible ambient temp. 5...40 °C Bath opening W x D / BD 120 x 110 / 150 mm | 4.72 x 4.33 / 5.91 inches Bath volume 5 Liters | 1.32 gal Power supply 460V 3~ 60Hz Current max. 7,5 A
$37,350.00 - $37,850.00
Huber Unistat 915w with Pilot ONE
Huber Unistat 915w with Pilot ONE (Please Note: There is a 2 - 3 weeks lead time) Unistat Circulators are an ideal solution for fast and precise thermal control of externally connected applications. These systems offer rapid temperature change and a wide temperature range without having to change fluid. The new Pilot ONE controller features a navigation system with easily remembered icons and menus which are sorted by color to make routine work simpler. An amazing software guides you through your set up ensuring all the necessary settings are correct. Precise and reproducible temperature control results Fastest heating and cooling rate Wide temperature ranges with no fluid change Pilot ONE controller with 5.7“ touchscreen and comfortable menu navigation Adaptive temperature control, self-optimising Efficient circulation pump Data communication via LAN, internet, USB, RS232 and RS485 Efficient operation saves working time and operating costs Proven functionality for the process industry E-grade "Professional" included Download Data Sheet Click Here for 3 Year Warranty Online Registration Download Operating Manual General information & Temperature Controller Temperature range -90...250 °C Temperature stability ±0.02 °C ±0.01 °C Temperature control TAC, self-optimizing (True Adaptive Control) Display resolution 0.01 °C Alarm message optical, acoustical Controller Pilot ONE (E-grade "Professional") Safety class III / FL Protection class IP20 Dimensions (W x D x H) 630 x 704 x 1565 mm | 24.8 x 27.72 x 61.61 inches Weight 364 kg | 802.62 pounds Heating / Cooling Capacity Heating capacity 6 kW Cooling capacity 250 200 100 0 -20 -40 -60 -80 -90 °C 6,5 7,5 9 11 11 11 8,2 4,2 1,3 0,6 kW Cooling machine water-cooled Refrigerant 1. stage R507 (A1, H280) (2,9 kg) Refrigerant 2. stage R23 (A1, H280) (1,23 kg) Circulation Pump Pressure pump max. 110 lpm ; 1.5 bar | 29.06 gpm ; 21.75 psi Pump Connection M30x1,5 AG male Permissible viscosity 50 mm²/s Connections Pt100 connection Pt100 Analogue input via optional Com.G@te Analogue output via optional Com.G@te Digital interface RS232, Ethernet, USB Device, USB Host Operating Data Old sku 1055.0011.01 Permissible ambient temp. 5...40 °C Noise level 64 dB(A) Filling volume min. 3.9 Liters | 1.03 gal Volume of expansion 6.5 Liters | 1.72 gal Cooling water connection G3/4 AG Cooling water differential pressure min. 1 bar | 14.5 psi Cooling water pressure max. 6 bar | 87 psi Power supply 460V 3~ 60Hz Current max. 29 A
$131,900.00 - $132,400.00
Huber Unistat Tango with Pilot ONE
Huber Unistat Tango with Pilot ONE (Please Note: There is 2-3 weeks Shipping lead time) Unistats are predestined for applications in process and chemical engineering, such as temperature control of reactors, autoclaves, Miniplant/Pilot systems, reactor blocks and calorimeters. Unistat temperature control systems with their unique thermodynamics provide highly accurate and reproducible results, guaranteeing the shortest heating and cooling times and a wide temperature range without fluid change. Environmentally and economically Unistats stand out, offering natural refrigerants and an efficient energy management system for reduced operating costs. . Precise and reproducible temperature control results Fastest heating and cooling rates Wide temperature ranges with no fluid change Pilot ONE controller with 5.7“ touchscreen and comfortable menu navigation Adaptive temperature control, self-optimising Efficient circulation pump 2 x USB (Host and Device), Ethernet and RS232 interfaces Efficient operation saves working time and operating costs Proven functionality for the process industry E-grade "Professional" included Download Data sheet Unistat tango Download Data Sheet Unistat tango w Download Data Sheet Unistat tango wl Operating Manual Click here 3 year Warranty Register General Information & Temperature Controller Unistat Tango Unistat Tango w Unistat Tango wl Temperature range -45...250 °C -45...250 °C -45...250 °C Temperature stability ±0.01 °C ±0.01 ±0.01 °C Temperature control TAC, self-optimizing (True Adaptive Control) TAC, self-optimizing (True Adaptive Control) TAC, self-optimizing (True Adaptive Control) Display resolution 0.01 °C 0.01 °C 0.01 °C Alarm message optical, acoustical optical, acoustical optical, acoustical Controller Pilot ONE (E-grade "Professional") Pilot ONE (E-grade "Professional") Pilot ONE (E-grade "Professional") Safety class III / FL III / FL III / FL Protection class IP20 IP20 IP20 Dimensions (W x D x H) 16.77 x 12.87 x 24.84 inches 16.77 x 12.87 x 24.84 inches 16.77 x 12.87 x 24.84 inches Weight 141.12 pounds 119.07 pounds 132.3 pounds Heating / Cooling Capacity Heating capacity 3 kW 3 kW 3 kW Cooling capacity 250 200 100 0 -20 -40 °C0,7 0,7 0,7 0,7 0,4 0,06 kW 250 200 100 0 -20 -40 °C0,7 0,7 0,7 0,7 0,4 0,06 kW 250 200 100 0 -20 -40 °C0,7 0,7 0,7 0,7 0,4 0,06 kW Cooling machine air-cooled water-cooled air- and water-cooled Refrigerant R1270 (0,15 kg) R1270 (0,09 kg R1270 (0,15 kg) Circulation Pump Pressure pump max. 55 lpm ; 0.9 bar | 14.53 gpm ; 13.05 psi 55 lpm ; 0.9 bar | 14.53 gpm ; 130.5 psi 55 lpm ; 0.9 bar | 14.53 gpm ; 130.5 psi Pump connection M24x1,5 AG male M24x1,5 AG male M24x1,5 AG male Permissible viscosity 50 mm²/s 50 mm²/s Connections Pt100 connection Pt100 Pt100 Pt100 Analogue input via optional Com.G@te via optional Com.G@te via optional Com.G@te Analogue outpu via optional Com.G@te via optional Com.G@te via optional Com.G@te Digital interface RS232, Ethernet, USB Device, USB Host RS232, Ethernet, USB Device, USB Host RS232, Ethernet, USB Device, USB Host Operating Data Permissible ambient temp. 5 to 40 °C 5 to 40 °C 5 to 40 °C Noise level 62 dB(A) - 62 dB(A) Filling volume min. 1.5 Liters | 0.4 gal 1.5 Liters | 0.4 gal 1.5 Liters | 0.4 gal Volume of expansion 2.8 Liters | 0.74 gal 2.8 Liters | 0.74 gal 2.8 Liters | 0.74 gal Cooling water connection - G1/2 AG G1/2 AG Cooling water consumption - 24 l/h 30 l/h Cooling water differential pressure min. - 0,5 bar | 72.5 psi 0,5 bar | 72.5 psi Cooling water pressure max. - 6 bar | 87 psi 6 bar | 87 psi Power supply 208V 2~ 60Hz 208V 2~ 60Hz 208V 2~ 60Hz Current max 18 A 16,5 A 17,5 A Fusing 20 A 2x20 A 2x20 A
$28,000.00 - $30,500.00
AFS 2.5" Disposable Color Remediation Cartridge
AFS Disposable Color Remediation Cartridge Note: Stainless Steel filter housing sold separately. (Click Here for Housing) AFS Instruction Manual Download Here AFS Filters are the first and only disposable color remediation filter cartridges for the botanical extraction industry. Our Patent Pending design allows for an easy to use solution implemented into existing extraction systems and is now available as a standard integration from many equipment manufacturers. AFS Filters are a simple solution that allows for the use of prepackaged filters, which are available in different recipes depending on the application. With the integrated 2.5µm paper filter molded and sealed into the cup, there is no media leak through. Pre-packed means there's no need to be an expert in remediation filter media and how to construct filters; as well as eliminates the messy process of building/packing filters yourself. Disposable offers no need for cleaning the filter housings afterward and trying to un-clog stainless filter screens. Less R&D investment, less mess, and less downtime allows for higher throughput and more profit. These come in light, medium, and heavy filtration. Learn more about each: Light Filtration is the trimmed down version of the standard Medium filter. These are best suited for extractions using fresh high-end input materials that only needs a light cleaning. Medium Filtration is our standard go-to filter. This is the most commonly used and sold filter AFS offers.. It's great for general filtration and lightening of extracted products. Heavy Filtration is packed with the highest amount of active extraction media. These filters are best suited for exceptionally dark extractions or for extractions with normal input materials where the desired outcome is closer to clear. Heavy filters offer the highest level of filtration. Technical Specifications: Life Span: 1 Time use, 5-7 lbs. of dry material. Temperature Rating: -40°C-70°C Top Seal: Induction Sealed (No glue is used) Filter: Cellulose Paper Pressure Rating: Recommended 60psi, Paper will hold 80-90 psi Max. Media: Proprietary licensed recipe. Shell Material: Polypropylene Excellent compatibility and Safe for chemicals in our industry (Butane, Propane, Ethanol). Pressure Method: Nitrogen Assist, unless you open blast CRC. Then you can assist with an air compressor. Click here to see SDS Sheet *Please recycle your spent Cartridges.
$72.99 - $929.99
AFS Tri-Clamp Inline Filter Housing for Disposable Color Remediation Cartridges
AFS Tri-Clamp Inline Filter Housing for Disposable Color Remediation Cartridges Note: Disposable cartridges sold separately. (Click Here for Cartridges) This inline housing allows for implementation of the AFS filters into many extraction systems. The AFS filter housing is 2.5" but comes with the adapter flanges for both ends to go inline with a standard 1.5" or 2" tri-clamp system. Kit Includes 2x 2.5" High Pressure Clamps 1x 2.5" Buna-N Gasket 2x Reducers 2.5" to 1.5" or 2" Tri-clamp 1x Cartridge Housing AFS Instruction Manual Download Here AFS SDS Sheet
$200.00
Julabo CORIO CD-200F
Julabo CORIO CD-200F Call for lead time Refrigerated / Heating Circulators of the new CORIO series distinguish themselves with a great price-to-performance ratio. They are ideal for all standard tasks and routine work in laboratories and industry. Included with each unit: 2 each barbed fitting for tubing 8 and 12 mm inner dia. (pump connections M16x1 male) Key Benefits: Models for internal and external applications Bright, white, easy to read display Very quiet Easy pump change-over (internal and external circulation) External pump connections (M16x1) USB connection Space-saving cooling coil design yields more usable space in the bath tank Bath lid and drain tap included Removable ventilation grid Refrigeration unit without side vents Class III (FL) according to DIN 12876-1 Specifications Order No. 9012701 Model series CORIO Category Refrigerated - Heating Circulators Working temperature range (°C) -20 ... +150 Temperature control PID Temperature stability (°C) ±0.03 Setting / display resolution 0.01 – 0.1 °C Temperature Display LED Heating capacity (kW) 1 Cooling capacity (Medium Ethanol) °C 20 0 -20kW 0.22 0.17 0.06 Pump capacity flow rate (l/min) 15 Pump capacity flow pressure (psi) 5.08 Bath opening / bath depth (W x L / D inch) 5.1 x 5.9 / 5.9 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 3 ... 4 Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 70 Global Warming Potential for 1430 Carbon dioxide equivalent stage 1 (t) 0.1 Ambient temperature 5...40 °C Dimensions W x L x H (inch) 9.1 x 15.4 x 25,6 Weight (LBS) 57.4 Included with each unit 2 each barbed fitting for tubing 8 and 12 mm inner dia. (pump connections M16x1 male) Bath tank Stainless steel Bath cover integrated Cooling of compressor Air Product Data Sheet Manual
$5,999.00
Julabo SE-6
Julabo SE-6 JULABO Heating Circulators with stainless steel bath tanks are mainly used for internal and external temperature tasks. The new range of these models now have increased capacities, allowing for temperature application of larger external systems, as well as open systems. Simultaneous temperature applications of smaller objects can also be carried out directly in the internal bath of the circulator. Models from the TopTech and HighTech Series are available with different bath sizes and features. Accessories for these units include test tube racks, bath covers etc. An integrated cooling coil is provided for temperature applications at near ambient or just below. Included with each unit: 2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 female). Key Benefits: VFD COMFORT DISPLAY Keypad for setpoints, warning/safety values and menu functions ICC (Intelligent Cascade Control), self-optimizing temperature control ATC3 3-Point-Calibration Pt100 External sensor connection for measurement and control SMART PUMP, electronically adjustable pump stages Early warning system for low liquid level (DBGM 203 06 059.8) Adjustable high temperature cut-out, visible via display RS232 interface for online communication Integrated programmer for 10 program steps Specification Order No. 9252506 Model series HighTech Category Heating Circulators Working temperature range (°C) +20 ... +300 Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 1x10 steps Temperature Display VFD Heating capacity (kW) 3 Pump capacity flow rate (l/min) 22-26 Pump capacity flow pressure (psi) 5.8-10.2 Pump capacity flow suction (psi) 2.9-5.8 Bath opening / bath depth (W x L / D inch) 5.1 x 5.9 / 7.9 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 6 External Pt100 sensor connection integrated Digital interfaces RS232Optional Profibus Ambient temperature 5...40 °C Dimensions W x L x H (inch) 8.3 x 16.9 x 17.3 Weight (LBS) 29.7 Classification according to DIN12876-1 Classification III (FL) Description Built-in cooling coil for tap water connection for temperature applications below or near ambient temperatures are integrated. Included with each unit 2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 male). Cooling coil integrated Bath tank Stainless steel Power requirement V / Hz / A 230/50-60/13 Additional voltage versions available Product Data Sheet Manual
$3,512.88 - $4,228.88
Julabo CORIO CP-1001F
Julabo CORIO CP-1001F Call for lead time Refrigerated Circulators from the CORIO CP range are suitable for applications with a temperature range up to +200°C. The enhanced pump performance ensures they are suitable for easy temperature control tasks in combination with external applications. Included with each unit: 2 each barbed fitting for tubing 8 and 12 mm inner dia. (pump connections M16x1 male) Key Benefits: Models for internal and external applications Bright, white, easy to read display Very quiet Easy pump change-over (internal and external circulation) External pump connections (M16x1) USB & RS232 connection Space-saving cooling coil design yields more usable space in the bath tank Bath lid and drain tap included Removable ventilation grid Refrigeration unit without side vents Class III (FL) according to DIN 12876-1 Technical Data Order No. 9013708 Model series CORIO Category Refrigerated - Heating Circulators Working temperature range (°C) -38 ... +100 Temperature control PID Temperature stability (°C) ±0.03 Setting / display resolution 0.01 – 0.1 °C Temperature Display LED Heating capacity (kW) 1 Cooling capacity (Medium Ethanol) °C 20 10 0 -10 -20 -30 kW 1 0.95 0.9 0.6 0.6 0.12 Pump capacity flow rate (l/min) 8 ... 27 Pump capacity flow pressure (psi) 1.5 ... 10.2 Bath opening / bath depth (W x L / D inch) 13.8 x 16.1 x 11.8 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 42 ... 56 Refrigerant stage 1 R449a Filling volume refrigerant stage 1 (g) 170 Ambient temperature 5...40 °C Dimensions W x L x H (inch) 17.7 x 25.2 x 37.4 Weight (LBS) 162.5 Included with each unit 2 each barbed fitting for tubing 8 and 12 mm inner dia. (pump connections M16x1 male) Bath tank Stainless steel Bath cover integrated Cooling of compressor Air Manual
$13,745.41
Julabo CORIO CP-BC12
Julabo CORIO CP-BC12 Call for lead time CORIO heating circulators feature professional technology for high standards. These units facilitate internal temperature control in the bath tank or control of externally connected applications. Included with each unit: 2 each barbed fitting for tubing 8 and 12 mm inner dia. (pump connections M16x1 male) Key Benefits: Models for internal and external applications Bright, white, easy to read display Very quiet Easy pump change-over between internal and external circulation USB & RS232 connection High-quality bath tanks made of stainless steel with bath lid and drain tap Integrated cooling coil for counter-cooling Technical Data Order No. 9013512 Model series CORIO Category Heating Circulators Working temperature range (°C) +20 ... +200 Temperature stability (°C) ±0.02 Setting / display resolution 0.01 – 0.1 °C Temperature Display LED Heating capacity (kW) 1 Pump capacity flow rate (l/min) 8 ... 27 Pump capacity flow pressure (psi) 1.5 ... 10.2 Bath opening / bath depth (W x L / D inch) 8.7 x 5.9 / 7.9 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 8.5 ... 12 Ambient temperature 5...40 °C Dimensions W x L x H (inch) 29.9 x 52 Weight (LBS) 13 x 19.3 x 18.5 Description Built-in cooling coil for tap water connection for temperature applications below or near ambient temperatures are integrated. Included with each unit 2 each barbed fitting for tubing 8 and 12 mm inner dia. (pump connections M16x1 male) Cooling coil integrated Bath tank Stainless steel Bath cover integrated Manual
$4,653.00
You have seen 288 out of 416 products